manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. GeneralAire
  6. •
  7. Humidifier
  8. •
  9. GeneralAire GENERAL 65 User manual

GeneralAire GENERAL 65 User manual

Other GeneralAire Humidifier manuals

GeneralAire 5500 Guide

GeneralAire

GeneralAire 5500 Guide

GeneralAire GENERAL 81 User manual

GeneralAire

GeneralAire GENERAL 81 User manual

GeneralAire Elite Steam User manual

GeneralAire

GeneralAire Elite Steam User manual

GeneralAire 4400A User manual

GeneralAire

GeneralAire 4400A User manual

GeneralAire 1099LHS User manual

GeneralAire

GeneralAire 1099LHS User manual

GeneralAire 747-L Quick start guide

GeneralAire

GeneralAire 747-L Quick start guide

GeneralAire Elite Steam RS20A User manual

GeneralAire

GeneralAire Elite Steam RS20A User manual

GeneralAire GF-1099LHS User manual

GeneralAire

GeneralAire GF-1099LHS User manual

GeneralAire 900 SERIES Operation manual

GeneralAire

GeneralAire 900 SERIES Operation manual

GeneralAire Elite Steam User manual

GeneralAire

GeneralAire Elite Steam User manual

GeneralAire GF4200DMD User manual

GeneralAire

GeneralAire GF4200DMD User manual

GeneralAire 1137 Series User manual

GeneralAire

GeneralAire 1137 Series User manual

GeneralAire 5500 Instruction Manual

GeneralAire

GeneralAire 5500 Instruction Manual

GeneralAire Elite Steam User manual

GeneralAire

GeneralAire Elite Steam User manual

GeneralAire 1000 SERIES User manual

GeneralAire

GeneralAire 1000 SERIES User manual

GeneralAire Elite Steam User manual

GeneralAire

GeneralAire Elite Steam User manual

GeneralAire 950 Series User manual

GeneralAire

GeneralAire 950 Series User manual

GeneralAire Elite Stream User manual

GeneralAire

GeneralAire Elite Stream User manual

GeneralAire 1042LH Operating instructions

GeneralAire

GeneralAire 1042LH Operating instructions

GeneralAire 1042 Series User manual

GeneralAire

GeneralAire 1042 Series User manual

GeneralAire GF-1137L Operating instructions

GeneralAire

GeneralAire GF-1137L Operating instructions

GeneralAire Elite Steam Installation guide

GeneralAire

GeneralAire Elite Steam Installation guide

GeneralAire 1000 SERIES User manual

GeneralAire

GeneralAire 1000 SERIES User manual

GeneralAire 570 Series User manual

GeneralAire

GeneralAire 570 Series User manual

Popular Humidifier manuals by other brands

Scarlett Comfort SC-AH986E22 instruction manual

Scarlett

Scarlett Comfort SC-AH986E22 instruction manual

SOLAC HU1060 Instructions for use

SOLAC

SOLAC HU1060 Instructions for use

Vicks FilterFree use and care manual

Vicks

Vicks FilterFree use and care manual

Philips HU4902 quick start guide

Philips

Philips HU4902 quick start guide

Bionaire CM1 Instruction leaflet

Bionaire

Bionaire CM1 Instruction leaflet

Air-O-Swiss AOS 7131 Instructions for use manual

Air-O-Swiss

Air-O-Swiss AOS 7131 Instructions for use manual

Vitek VT-1768 BK Manual instruction

Vitek

Vitek VT-1768 BK Manual instruction

KING K 5002 Rainbow instruction manual

KING

KING K 5002 Rainbow instruction manual

Crane EE-6902 instruction manual

Crane

Crane EE-6902 instruction manual

Glaziar Ness user manual

Glaziar

Glaziar Ness user manual

Philips DreamStation Go Faqs

Philips

Philips DreamStation Go Faqs

Honeywell MISTMATE HUL520BC manual

Honeywell

Honeywell MISTMATE HUL520BC manual

Stadler Form Hera Operation instructions

Stadler Form

Stadler Form Hera Operation instructions

Hunter 31206 owner's guide

Hunter

Hunter 31206 owner's guide

TaoTronics TT-AH004 user guide

TaoTronics

TaoTronics TT-AH004 user guide

adorini Cigar Heaven manual

adorini

adorini Cigar Heaven manual

Aprilaire 800 Series user manual

Aprilaire

Aprilaire 800 Series user manual

Pyle SereneLife PHUMDIF8 Instruction book

Pyle

Pyle SereneLife PHUMDIF8 Instruction book

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

INSTALLATION INSTRUCTIONS
INSTRUCTIONS POUR L 'INSTALLA TION DE L'HUMIDIF!CA TEUR
GENERALAIRE® MODE-LE 65
i
POWER
HUMIDIFIER
FOR INSTALLATION ON A VERTICAL PLENUM
SURFACE OF ANY FORCED AIR FURNACE
The Generalaire® Power Humidifier is based on the evaporative pad method of adding moisture to the air. A polyurethane pad forms the surface of a
slowly rotating drum which is wetted as it turns in an automatically controlled level of water and is installed on a vertical plenum surface of any forced air
furnace. It is recommended that the humidifier be mounted on the return air plenum. These illustrations show the humidifier installed with the 5" outlet
to the right. The humidifier may also be installed with the 5" outlet to the left by reversing the motor mounting plate and the by-pass collar The float
valve must be installed on the same side as the drive motor.
L'humidificateur electrique GENERALAIRE® a pour principe de disperser dans I'air I'humidite qui s'evapore a partir d'un manchon de polyurethane
monte sur un tambour rotatif partiellement immerge dans une ouvette d'eau a niveau contrele ; oet humidificateur se pose sur la pardi erticale de la
ohambre a air (plenum) de route fournaise a air chaud et circulation forcee. On reoommande de I'installer sur la chambre a air de retour. Les figures
montrent I'humidifioateur monte aveola sortie de 5" pc dirigee vers la droit. Mais si I'on desire placer la sortie de " du cote gauche, il faut intervertir la
plaque de montage du moteur et le collier de derivation. A soupape du flotteur doit etre installee du meme cete que le moteur.
.... -_.#::.... _y@,.!p.,_,._--.-_.;_..:-.
, l
-,i.- [email protected]
Select location on vertical surface of return air plenum for mounting
humidifier. Stick mounting template in place. Make sure the template is
level.
C,#oisir I'ernplaceme,_Tt cur la pardi vertiea/e de la chambre 9 a# de retour,
puis y Pb_erle gabarit en pre,_a,_Ttsoir,, de le placer blen au niveau
Center punch the 5 mounting holes on the template and drill with a I/8" drill.
Cut out center section of template. E_end horizontal centerline from template
to the adjacent plenum. Remove remaining template and start five sheet metal
screws. Mount humidifier cabinet in level position and tighten screws. On light
gauge plenums use two additional screws at top of cabinet for support.
Apres avo# marque #emplacement des cmq (5) ws b I'aide d'un pointeau, faire
les trous avec une perceuse 6qul:Dee d'une m_cDe de 1/8! Decouper la pattie
centrale du G,abariL Prolonger la I,ignehor/zontale depu/s le milieu du gabafit
jusqu'b /a chambre b air voisme. En/ever /e restant du gabarff et engager cmq
v/s b terb/anter/e. Poser le bo/tier de/'humid/t/cateur au n/veau, et serrer les
v/s. Sur une pardi mince, on doit poser deux v/s supplementa/res darts le haut
,DOUrb/en supporter/e bortieL
f
L
Slide water pan into humidifier and assemble float on same side
as drive motor.
Placer/a cuvette d'eau darts/'humiditicateur et mstat/er le
flotteur du m6me c6t6 que /e moteu_
Scribe 5" diameter circle on plenum adjacent to humidifier for cutting by-
pass opening. Locate vertical centerline of circle 10" to 15" from side
of humidifier on cabinet center-line. Cut 5" hole and install by-pass pipe
by bending tabs of collar down. Drill I/8" holes through top and bottom
of 5" pipe and humidifier flange Secure with sheet metal screws
NOTE: If furnace is used for summer cooling, close inline damper
in by=pass pipe.
Tracer un cercle de 5 pc de diamctre sur le plenum adjacent
I'humidificateur pour decouper I'ouverture de derivation. Placer I'axe
central vertical du cercle a une distance de 10 po a 15 pc du cOte de
I'humidificateur sur I'axe central du boi"tier. Deoouper le trou de 5 poet
installer letuyau de derivation en pliant vers le bas les pattes du
manchon Percer des trous de 1/8 po darts les parties superieure et
inferieure du tuyau de 5 poet de la bride de I'humidifioateur Fixer
I'aide de vis pour tOle.
REMARQUE: Si ia fournaise eat utilisCe pour refroidir la maison
pendant Fete, former le registre incorpore dana le tuyau de
dSrivation.
Remove paper backing from valve hole cover plate and stick over
valve hole that is not being used.
Entever te pap/or as; dos de/a p/aque recouvrant /'or/tice de/a
soupape et te ptacer sur /'o,riflce de so_,pape qui ne servira paa
Assemble drum into humidifier cabinet by engaging drive on one end of
drum shaft with the slotted motor coupling. Place opposite end of drum
shaft in bearing. DO NOT ROTATE DRUM MANUALLY OR DAMAGE TO
MOTOR GEAR TRAIN MAY RESULT.
Assembler le tambour dans le boi'ter en glissant le dispositif d'entrainement,
situe a un bout de I'arbre, dans le couplage du moteur a fentes. Placer
I'autre exLremite de I'arbre du tambour dans le palier. NE PAS FAIR
TOURNER LE TAMBOUR A LA MAIN, CAR CA POURRAIT
ENDOMMAGER L'ENDOMMAGER L'ENGRENAGE DU MOTEUR.
jJJ
J
_J
J<
Mount the self tapping saddle valve on a cold water pipe. Follow the
instructions on the valve package. A side or top mount is best to avoid
clogging from pipe sediment
Montez le robinet-vanne a etrier auto-taraudant sur une canalisation
d'eau froide. Suives les instructions sur I'emballage du robinet. II est
preferable de le monter sur le cote ou sur le dessus de la canalisation
pour eviter que les sediments ne le bouchent.
Connect!4."O.D.tubingtothesaddlevalve.Coppertubingrequiresabrass
compressionnutandbrasssleeve.Plastictubingrequiresabrassinsert
insidethetubing,aplasticsleeveontheoutsidewithabrasscompression
nut.DONOTUSEPLASTICTUBINGONHOTWATERORINCONTACT
WITHANYHOTPLENUMSURFACEORDUCT.
Connecter le tube de _" D.E. b la soupape de I'attache. Avec us tube es cu/vre,
on doit employer use vtrole es laitos et us 6crou b compression es laitos. Les
tubes de plastique requi@rest use pi@ce de laitos b I'ist6rieur amsi qu'use doullle
de plastique b !'ext_rieur avec us 6crou b compression es laitos. NE PAS
EMPLO YER DE TUBE EN PLASTIQUE POUR DE L'EAU CNAUDE OU S/LE
TUBE EST EN CONTACT AVEC UNE SURFACE CNAUDE DE LA CHAMBRE
AIR.
:>
_ COPPER
TUB ING
_j PLASTIC
_) (} _)TUBING
Open saddle valve for several seconds to flush dirt from pipe and tubing
Connect the !4." water supply tubing to the humidifier
Ouvrlr/a soupape de I'attache pesdast plusieurs secosdes pour _/im/ser
/es salet6s costesues dass le tube et /e tuyau R_'corder /e tube de ¼"
qu/ am6se /'eau b /',#um/d/t/cateur.
Install 24 V. transformer on junction box with 120 V. primary leads
connected
to 120 V. power supply. Connect humidistat in series with the 24 V.
circuit.
Follow the installation instructions supplied with the humid/star. ALL
WIRING
SHOULD COMPLY WITH LOCAL ELECTRICAL CODES
Installer us trastormateur de 24 volts sur la bo£te de josct/os es reliant/es
cbbles pr/ma/res de 120 volts "bla source de courast de 120 volts.
Connecter/'hum/d/stat es serie avec le circuit de 24 volts. Su/vre /es
mstruct/oss toum/es aec I'hum/dlstat TOUTE LA F/LER/E DOlT ETRE
CONFORME AU>("CODES D'ELECTRICITE LOCAO%
120 VOLT
PC@4ERSUPPLY
HUMIDIFIER
MOTOR TR/_!4s_OLT I I HUMIDISTAT
II L____z=_zu - i i , ,
I
12[t,_ I#JlRING
2€V IX_IRIHe
TEST RUN HUMIDiFIER-Turn on water supply and check operation of humidifier. The float should maintain a water depth of
approximately 1 1/2". The water level may be adjusted by loosening the hex nut and moving the float assembly up or down.
The humidifier motor should turn the humidifier drum when the humid/star is set to a demand setting.
ESSAI DE L'HUMIDIFICATEUR-Ouvrir I'arrivee d'eau et verifier le fonctionnement de I'humidificateur Le flotteur doit
maintenir environ 1 !/2" d'eau dans la curette. On peut regler le niveau de I'eau en devissant I'ecrou hexagonal et en
rood/f/ant la hauteur de I'assemblage du flotteur, vers le haut ou vers le bas. Le moteur de I'humidifioateur devrait faire
tourner le tambour Iorsque I'humidistat est r6gle a un certain degre d'humidite
iNSTALLER: PLEASE LEAVE HOMEOWNER'S GUARANTEE CARD AND MAINTENANCE iNSTRUCTiONS ON SADDLE VALVE.
TYPICAL INSTALLATIONS
RETURN .O,IR RETURN AiR
S )-...
COUNTER-FLOWHIGH BOY LOW BOY
PARTS LIST FOR HUMIDIFIER
toTEMNO.
N° D'ARTICLE
I
5
6
l/
/
PARTS N.a_E PART NO.
NOM N° DE PIECE
DRUM SHAFT 12856
Arbre du tambour
RETAINER CLIP P-188
Agrafe
DRUM END-OPEN 12855
Ex.tr_mitedutambour-
ouvert
DRUM ASSEMBLY 12853
Assemblage du tambour
sans le manchon
EVAPORATOR SLEEVE 85-5
Manchon _vaporateur
DRUM END-CLOSED 12854
Extr_mit_ dutambour-
ferm_
CANADIAN
PART NO.
65-I0
81-10A
65-9
65-55
65.15
65-8
©
USA CANADIAN
ITEM NO. NAME PART NO, PART NO,
N° D'AR]ICLE NOM N° DE PIECE N° DEPIECE
7 COMERASSEMBLY 12858 85 GEN
(including window)
Assemblage du couvercle
avec fen_tre
8 WINDOW 12881 85-7
Fen_tre
9 MOTOR MOUNTING
PLATE 12852 85-2
Plaque de montage
du mdceur
10 COUPLING 727-11A 81-28
Coupiage d'entr?nement
11 MOTOR ASSEMBLY 727-40 81-50
Assemblage du moteur
12 ORIFICE NUT 975-3 81-12F
Ecrou de I'orifice
13 \/ALVE WASHER 747-11 81-12G
Rondelle de la soupape
14 SPLASH GUARD 727-8 81-12A
Garde contre
_claboussures
15 \f'AL_'ESHEILD 975-6 81-12E
Ecran de la soupage
18 ORIFICE F0q-ING 727-24 81-12B
Graniture de I'orifice
17 \/AL'VESEAT 975-1 81-120
Si_ge de lasoupage
18 COTTER PiN P-118 81-12C
Goupille
19 FLOAT ARM 81-11 81-11
Bras de la soupape
20 FLOAT 81-12 81-12
Flotteur
21 FLOAT ASSEMBLY 81-21 81-58
(consi_s ofitems 12
thru 20)
Assemblage du flotteur
22 BY-PASS COLLAR 12861 85-3
Collier de derivation
23 'v'ALvE HOLECOVER 81-14 81-14
Plaque de I'orifice de la
soupape
24 CABINET 12849 85-1
BoRer
25 SPEED NUT 40-7 81-13A
ECFOU
26 THUMB SCREW 81-18 81-18
Mis
27 \_ATE R PAN 12857 65-4
Cuvette _ eau
GENERAL FILTERS, INC.
43800 GRAND RIVER AVE.
NOVI, MI 48376=8025
CANADIAN GENERAL FILTERS, LTD.
39 CROCKFORD BLVD.
SCARBOROUGN, ONTARIO MI R 3B7
FORM NO 12870