Genesis Automation moTrona DX020 User manual

control – motion – interface
DX020
Tachometer and Frequency Counter
•Mini housing 48 x 24 mm (1.890 x 0.945’’)
•Bright LED display 6 decades/ 8mm (0.315’’)
•Add- on frame for 50 x 25 mm (1.969 x 0.984’’)
•10 – 30 Vdc power supply
•60 kHz of counting frequency with 24 Vdc power input
•Selectable filter for mechanical inputs
•Adjustable multiplier and divider
•Protection class IP65 on front
•Easy to set up by menu support
Operating Instructions

DX02002b_e.DOC / Jan-08 Page 2 / 9
Safety Instructions
•This manual is an essential part of the unit and contains important hints about
function, correct handling and commissioning. Non-observance can result in
damage to the unit or the machine or even in injury to persons using the
equipment!
•The unit must only be installed, connected and activated by a qualified electrician
•It is a must to observe all general and also all country-specific and application-
specific safety standards
•When this unit is used with applications where failure or maloperation could cause
damage to a machine or hazard to the operating staff, it is indispensable to meet
effective precautions in order to avoid such consequences
•Regarding installation, wiring, environmental conditions, screening of cables and
earthing, you must follow the general standards of industrial automation industry
•- Errors and omissions excepted –
Version: Description:
DX02001b/K/hk/Jan02 Valid for models until August, 2006
DX02002a/K/hk/Dec06 60 kHz, divider, brochure A5 format
DX02002b/hk/Aug07 Modification of temperature range

DX02002b_e.DOC / Jan-08 Page 3 / 9
Table of Contents
1. Operation of the front keys.............................................................................4
2. Operational parameters..................................................................................5
2.1. Input polarity .........................................................................................................5
2.2. Input filter..............................................................................................................5
2.3. Scaling factors.......................................................................................................5
2.4. Decimal point ........................................................................................................5
2.5. Display mode.........................................................................................................6
2.6. Maximum waiting time .........................................................................................6
2.7. End of program ......................................................................................................6
3. Terminal Assignment......................................................................................7
4. Delivery includes.............................................................................................7
5. Specifications .................................................................................................8
6. Dimensions .....................................................................................................9
6.1. Mounting without use of add-on frames ..............................................................9
6.2. Bezel 50 x 25 mm (1.969 x 0.984’’) for clip mounting ...........................................9
6.3. Bezel 50 x 25 mm (1.969 x 0.984’’) for screw mounting .......................................9

DX02002b_e.DOC / Jan-08 Page 4 / 9
1. Operation of the front keys
To enter the setup mode, keep both front keys down while you switch power on.
You can also enter the setup mode when the unit is already powered on, by keeping both front
keys down at the same time for approx. 5 seconds.
The display will then show
As soon as you release the keys, the display starts to alternate between the actual parameter
text and the associated setting, in a cycle of two seconds.
Press the key on the right to increment the actual set value to next.
For numeric entries, use the left key to select the decade and the right key to scroll the value.
To continue to the next parameter, keep the left key down while you press the right key.
When you have reached the item „Endprog“, you get the choice
−„Yes“: this will store your entries to the unit and switch to normal operation.
−„No“: this will start the menu again and your previous data will not be stored.

DX02002b_e.DOC / Jan-08 Page 5 / 9
2. Operational parameters
Please enter all of the subsequent parameters, like shown in section 1.
2.1. Input polarity
InPol
nPn NPN: The count input must switch to“0“
PnP PNP: The count input must switch to “+“.
Namur: Set to NPN. See section 3.
2.2. Input filter
Filter
oFF Filter off: maximum input frequency 60 kHz
On Filter on: maximum input frequency 30 Hz
2.3. Scaling factors
Factor
00.0001 Multiplies the input frequency with the factor
setting.
99.9999 Range 0.0001 to 99.9999.
Setting “0“ will not be accepted.
Divider
00.0001 Divides the input frequency by the divider setting.
99.9999 Setting range 0.0001 to 99.9999.
Setting “0“ will not be accepted.
2.4. Decimal point
dP
0
0.000
Adjustable between no decimal position and max.
3 decimal positions. This setting does not affect
the numeric value of the frequency display.

DX02002b_e.DOC / Jan-08 Page 6 / 9
2.5. Display mode
diSPm
Sec -1 The unit displays the frequency as number of
impulses per second (Hz). (With factor setting
1.0000)
Min -1 The unit displays the frequency as number of
impulses per minute. (With factor setting 1.0000).
2.6. Maximum waiting time
WAit0
01.1
99.9
This setting specifies the maximum waiting time
from one input impulse to the next, before the
display sets to zero.
Range 1.1 sec to 99.9 sec
2.7. End of program
EndPro
No Select “No“ to return to the beginning of the menu
for verification of settings.
YES Select “Yes“ to store data and exit the menu.

DX02002b_e.DOC / Jan-08 Page 7 / 9
3. Terminal Assignment
(also printed to the top of the unit)
+10...30VDC *
0V (GND)
Input
NC
1234
5
NC
+-
( Namur )
*With use of Namur sensors,
the minimum supply voltage
is 18 Volts.
4. Delivery includes
0Panel mounting clip
0Bezel for screw mount with panel cut out 50 x 25mm
0Bezel for clip mount with panel cut out 50 x 25mm
0Sealing

DX02002b_e.DOC / Jan-08 Page 8 / 9
5. Specifications
Power supply : 10...30 Vdc, max. 50mA
Display : 6 decades / 8mm (0.315’’)
Input : NPN / PNP / Namur, Ri = 10 kOhms
Counting frequency : with 12 volts power input: 20 kHz
with 24 volts power input: 60 kHz
with the filter switched on: 30 Hz)
Switching levels of input : Low = 0V.....0.2 x UB
(typical) High = 0.8 x UB...30V
Impulse shape : any (Schmitt Trigger)
Data retention : 106cycles / 10 years
Max. Error : < 0.1 %
Operating temperature : -20°... + 55° C (-4 … +131° F)
Storage temperature : -25°... + 70° C (-13 … +158° F)
Weight : 50g
Protection Class (front) : IP 65
Conformity and Standards : EMC 89/336/EEC: EN 61000-6-2
EN 61000-6-3
LV73/23/EEC: EN 61010-1

6. Dimensions
6.1. Mounting without use of add-on frames
6.2. Bezel 50 x 25 mm (1.969 x 0.984’’) for clip mounting
6.3. Bezel 50 x 25 mm (1.969 x 0.984’’) for screw mounting
max. 19.3
4,0 (0.157’’)
6,5 (0.256’’)
59,0 (2.323’’)
22 x45
48 ,0 (1 .890 ’’)
24 ,0 (.9 45’ ’)
22,2(+0,3)
45 ,0 (+0,6)
1. 772’’ (+ 0.024 )
0.874’’ (+ 0.012)
max.0.76’’
25 ,0 x 50, 0
53,0 (2.087’’)
26 ,0 (1.024 ’’)
1,0 (0 .039’’)
4,0 (0 .157’’)
25,0 +0,5
50,0 +0,6
(0.984 x 1.969 ’’)
(1.969 +0.024’’)
0.984 +0.020 ’’
56,0(2.205’’)
32,0 (1.260’’)
M3
40,0 (1.575’’)
32,0 + 0,1
25,0 x 50,0
1,0 (0.039’ ’)
4,0 (0 .157’ ’)
(0.984 x 1.969’’)
25 ,0 +0,5
0.984 +0.020’’
50,0 + 0,6
(1.969 +0.0 24’’)
(1. 260 +0 .0 04)
M3
A= Senkung Af3,DIN 74
Counterbore Af3, DIN 74
A
A
Table of contents
Popular Measuring Instrument manuals by other brands

TSI Instruments
TSI Instruments VELOCICALC 9565 Series Operation and service manual

Leader
Leader Search user manual

ABB
ABB LGR-ICOS GLA531 Series operating manual

Vaisala
Vaisala GMP252 user guide

Apera Instruments
Apera Instruments 9500 Premium Series user manual

Macherey-Nagel
Macherey-Nagel PF-12 Plus manual