User Manual Multi-Card Technology Reader – 13.56MHz, DesFire EV1 / EV2 and EM / HID
4
1.3 Specification
1.4 Mounting
1. Install the metal plate on the wall with two or four screws, which depends on different
kinds of gang box being installed (1).
2. The cover shall clip on the upper edge (2) the push in the bottom part as show in
diagram (3).
3. Tighten the secure non-dropout screw, which located underneath of the reader to fix
the reader and the back plate (4), installation is completed.
Re-configure Window 5 seconds (Default) or Half an hour after power up
Reader Output Format CSN/UID 32bits, 34bits, 56bits (backward/forward), file
content reading for programmed ID
Wiegand Plus Width Different choices to fit with different controller’s requirements
Buzzer Control Reader & controller control (Default) or controller control only
LED/Back Lit Control Define different LED colour response base on LED input
Typical Read Range 2 – 3 cm
Reader Standard Output Wiegand (RS232 & RS485 (OSDP) (optional)
Wiring Distance 150m (22 AWG with shielded cable)
Operating Voltage DC10 – 15V
Operating Current 150mA (max)
Operating Temperature -30°C – 70°C
Operating Humidity 10% – 90%
Dimensions 115.5 × 84.5 × 20.5mm
Weight 210g