Measurement Preparations
I
Accessories
Tripod, GeoMax telescopic aluminium staff, GeoMax 1 section,
fibreglassstaff.(Optional:sunshade,4rechargeablebatteriesand
charger)
3. Measurement Preparations
3.1 Change Battery
Insert 4 AA dry cells according to the positive and negative signs
as indicated on the holder.
)Always replace with a complete battery set!
)Do not use old and new batteries together.
)Do not use batteries from different manufacturers or
batteries of different types.
3.2 Set-up Instrument
Levelling
• Set up the tripod. Extend the legs to a suitable length and
ensure that the tripod head is approximately level. Tread the
tripod shoes firmly into the ground to ensure stability.
• Mounttheinstrumentonthetripodbyscrewingthetripodscrew
onto the base of the instrument.
• Usethethreelevellingfootscrewstocenterthecircularbubble
in order to level the instrument.
Eyepiece Adjustment
Point the telescope to a uniform light surface such as a wall or a
pieceofpaper.Turntheeyepieceuntilthecrosshairsaresharpor
distinct.
Target Image Focusing
Use the gunsight to aim the objective lens at the staff. Turn the
horizontalfinemotionscrewuntilthestaffisnearlycenteredinthe
field of view and then turn the focusing knob to focus on the staff.
Ensure that staff image and reticle are sharp or distinct.
Power ON
The instrument is ready to measure.
)Technical hints:
• First check and adjust the electronic and optical line-of-sight
errors, then the circular level on the instrument and then the
staff:beforestartingworkinthefield,afterlongstorageperiods
or after long transportation.
• Keep the optics clean. Dirt or condensation on the optics can
limit measurements.
• Before starting work, let the instrument adjust to the ambient
temperature (approx. 2 minutes per °C of temperature differ-
ence).
• Avoid measuring through window panes.
• Staff sections have to be fully extended and properly secured.
• Touching the upper third of the tripod, can damp vibrations at
the instrument due to wind.
• Use the lens hood to cover the objective when backlight
disturbs.
• Evenly illuminate the measuring area of the staff with a flash-
light or spotlight in darkness.