GFA 10004398 30010 User manual

f
Installation Instructions
ELEKTROMAT
SE 8.60 FU-25,40
Model: 10004398 30010
-en-
Status: 04.07.2022

2
GfA ELEKTROMATEN GmbH & Co. KG
Wiesenstraße 81
D-40549 Düsseldorf
www.gfa-elektromaten.de

3
Table of contents
1General safety information .............................................................................................. 4
2Technical data ................................................................................................................ 6
3Mechanical installation .................................................................................................... 7
4Electrical installation ....................................................................................................... 9
5Limit switch adjustment ................................................................................................. 10
6Emergency manual operation ....................................................................................... 11
7Completing commissioning / inspection......................................................................... 13
8Disposal........................................................................................................................ 14
9Declaration of incorporation / Declaration of conformity................................................. 15
▶▶
Symbols
Warning - Potential injury or danger to life!
Warning - Danger to life from electric current!
Note - Important information!
▶
Requirement - Required action!
Schematic representations are based on product examples. Deviations from delivered
products are possible.

4
1General safety information
Specified use
The drive unit is only intended for vertically moving sectional doors with full counter-
balancing.
The drive unit must be protected against moisture and aggressive environmental
conditions (such as corrosive substances). The drive units are only suitable for indoor use.
Appropriate protective measures must be taken for outdoor installation. The drive unit is
not intended for hazardous areas. The values specified in the technical data of the drive
unit must not be exceeded. The safe operation can only be ensured if used as specified.
Target audience of these installation instructions
These installation instructions are geared towards qualified persons trained in the handling
of door systems. Expert knowledge, relevant skills and practical experience are what set
apart qualified persons. They are capable of safely carrying out the tasks involving
installation, maintenance and modernisation according to the instructions.
Safe operation
The safe operation of the product can only be ensured if it is used as specified. Follow the
installation instructions. Observe all specifications, especially warnings, when installing the
product in the overall system. GfA is not liable for damage resulting from non-observance
of the installation instructions. The resulting overall system must be reassessed for its
safety in accordance with applicable standards and directives (e.g. CE marking). These
installation instructions refer only to a part of the overall system and are not sufficient as
the sole instructions for the overall system. The installer of the system must prepare the
instructions for the overall system. We recommend entering the danger area of the system
only when the drive unit is at a standstill.

5
Warning - Failure to follow these installation instructions may result in severe injury or death.
Please read these instructions before using the product.
Keep these instructions handy.
Include these instructions when passing on the product to third parties.
Warning - Danger from improper use of the product!
Do not let children operate the product unsupervised or use as a toy.
Warning - Danger to life from incorrect installation!
Work carried out improperly may result in death or severe injury from electrical
current or falling parts.
Allow only competent people to carry out the work.
Disconnect all cables from the power supply.
Observe valid regulations and standards.
Use suitable tools.
Warning! Danger to life from falling objects if the drive unit is subjected to
impermissible forces.
Inadmissible forces (examples: collision with a forklift, dropping the drive unit, tearing
or pulling on the motor) lead to damage to the drive unit. There is a risk of severe
injury or death from falling objects.
Prevent impermissible forces from acting on the drive unit,
Check the drive unit for damage if impermissible forces have acted on it. Look
even for minor damage. Lock the door during the inspection.
Contact the service department if you have difficulty assessing the damage.

6
2Technical data
Designation
Unit
Output speed
60
rpm
Output torque
80 (50) 1)
Nm
Output / hollow shaft
25,40
mm
Series
SG 40
-
Limit switch range
(maximum revolutions of the output / hollow shaft)
26
-
Supply voltage
1N~ 230 / 3~ 230
V
Operating current
2,10
A
Operating frequency
50/60
Hz
Power factor cos φ
0,85
-
Safety circuit
24
V
Degree of protection
IP 65
-
Temperature range
+5 / +40 (+60) 2)
°C
Operating sound pressure level
< 70
dB(A)
Output speed OPEN
12-60
min-1
Output speed CLOSE
12-24
min-1
Output speed CLOSE > 2,5 m
12-30
min-1
Cycles per hour
12 (10,2)1)
h-1
Max. holding torque
390
Nm
Max. load
3200
N
1) Specification in ( ) according to EN 60335-2-103.
2) When using a temperature range of +40°...+60°C use half of maximum cycles per hour.

7
3Mechanical installation
Prerequisites
The permissible loads on walls, fastenings, mountings and transmission elements must not
be exceeded, even for maximum holding torques or locking torques (▶ refer to technical
data).
Connection elements:
▶Self-locking connection
elements with a minimum
strength of 800 N/mm2
(8.8) must be used.
▶Utilize the hole diameter
to the full.
▶Use adequately
dimensioned washers for
elongated holes.
BAGAB00002_Z002
BAGAB00003_Z002
3 : 1
Permissible mounting positions

8
Mounting
Fourt threads are provided for mounting.
▶Use at least 2 of these.
Additional mounting options

9
4Electrical installation
Warning - Danger to life from electric current!
Switch the mains OFF and check that the cables are de-energised
Observe the applicable regulations and standards
Make the electrical connection according to standard
Use suitable tools
Performing electrical installation
▶Insert plug.
▶Tighten nuts to 6 Nm.
Completing the electrical installation
Mount the cable entries and/or cable glands.
Connection of external emergency switches !
External emergency switches (release, for example, in case of spring breakage,
slack rope, etc.) must be connected over the door control.

10
5Limit switch adjustment
The adjustment of the final limit positions
OPEN and CLOSE is described in the
instructions for the door control panel.
The door control must meet Performance Level c!
Use only door controls that evaluate the limit switch according to EN 12453 and meet
Performance Level c.

11
6Emergency manual operation
Emergency manual operation is designed for opening or closing the door without power
supply. Its activation interrupts the control voltage. Electrical operation is no longer possible.
Warning –Injuries due to incorrect operation!
Switch off voltage.
Warning - Danger of the door dropping!
If you need to apply more than the permissible force of 390N (according to DIN EN
12604/DIN EN 12453) to move the door by emergency manual operation, this
indicates a stalling on the drive unit or door. Releasing the stalling may cause the
door to drop.
Take a safe stand.
For drive units with brake, the emergency manual operation must be carried out
against the closed brake.
Caution - Risk of injury due to unexpected movement!
The emergency manual operation has an integrated overload protection. The
overload protection causes a disconnection of the force transmission in the case of
unbalanced doors. In this case, the chain slips.
Take a safe stand.
Check the counter-balancing of the door in case of a triggering overload
protection.
Caution –Damage to components!
Do not move the door beyond the final limit positions.

12
Ⓐ: Attach tool (①). Switch on by turning to
the right until stop (②).
Ⓑ: Switch on by pulling the red handle.
Ⓐ+Ⓑ: Open (③) or close (④) the door by
pulling the chain by hand.
Ⓐ: Attach tool (⑤). Switch off by turning to
the left until stop (⑥).
Ⓑ: Switch off by turning to the right until stop.

13
7Completing commissioning / inspection
Check the following components and then install all covers.
Gearbox
Check the drive unit for loss of oil (a few drops can be neglected). Protect the output-shaft
permanently against corrosion.
Mounting
Check that all connection elements (consoles, torque mounts, screws, locking rings, etc.) are
secure and in proper condition.
Electrical wiring
Check the connection cables and cabling for damage or crushing. Check that the screw
connections and plug connections are fitted properly with a good electric contact.
Emergency manual operation
Check the function with the power disconnected. Perform the check only between the final
limit positions.
Limit switch
Check the final limit positions by opening and closing fully. The safety area must not be
approached.
Drive unit
Note!
Engage a qualified engineer to check the drive unit annually
Apply shorter inspection intervals for doors that are operated frequently
Observe the applicable regulations and standards

14
8Disposal
Dispose of packaging
Dispose of the packaging material properly according to the local legal regulations or recycle
it.
Dispose of old devices
Dispose of old devices properly according to local legal regulations. Return old devices to the
return and collection systems available. You can also return GfA products free of charge.
Please apply enough postage to the package and mark it as "old devices".
Notice- Environmental damage!
The gearbox contains oil.
Ensure proper disposal according to local legal regulations.

15
9Declarationof incorporation / Declarationof c onformity
Declaration of incorporation
within the meaning of Machinery Directive 2006/42/EC
for partly completed machinery, Appendix II Part B
Declaration of conformity
within the meaning of EMC Directive 2014/30/EU
within the meaning of RoHS Directive 2011/65/EU
We,
GfA ELEKTROMATEN GmbH & Co. KG
declare under our sole responsibility that the
following product complies with the above
directives and is only intended for installation in a
door system.
Drive unit
SE 8.60 FU-25,40
Part no.: 10004398 30010
We undertake to transmit in response to a
reasoned request by the appropriate regulatory
authorities the special documents on the partly
completed machinery.
This product must only be put into operation
when it has been determined that the complete
machine/system in which it has been installed
complies with the provisions of the above-
mentioned directives.
Authorised representative to compile the
technical documents is the undersigned.
Düsseldorf, 10.08.2018
Stephan Kleine
CEO
Signature
The following requirements from Appendix I of
the Machinery Directive 2006/42/EC are met:
1.1.2, 1.1.3, 1.1.5, 1.2.2, 1.2.3, 1.2.6, 1.3.2,
1.3.3, 1.3.9, 1.5.1, 1.5.2, 1.5.4, 1.5.6, 1.5.7,
1.5.8, 1.5.9, 1.5.10, 1.5.11, 1.5.13, 1.6.1, 1.6.2,
1.6.4, 1.7.2, 1.7.3, 1.7.4.3.
Standards applied:
EN 12453:2001
Industrial, commercial and garage doors and
gates - Safety in use of power operated doors -
Requirements
EN 12604:2017
Industrial, commercial and garage doors and
gates - Mechanical aspects - Requirements
EN 60335-1:2012
Household and similar electrical appliances -
Safety - Part 1: General requirements
EN 61000-6-2:2005
Electromagnetic compatibility (EMC) Part 6-2
Generic standards –Immunity standard for
industrial environments
EN 61000-6-3:2007
Electromagnetic compatibility (EMC) Part 6-3
Generic standards –Emission standard for
residential, commercial and light-industrial
environments
This manual suits for next models
1
Table of contents
Other GFA Industrial Electrical manuals
Popular Industrial Electrical manuals by other brands

Murata
Murata GRM1555C2A7R5DA01 Series Reference sheet

Dorma
Dorma ES84 Series installation instructions

Hellermann Tyton
Hellermann Tyton Reliseal Series installation instructions

KEBCO
KEBCO COMBIVERT F5 Applications manual

red lion
red lion VT-IPm2m-***-D Series Installation and maintenance manual

Hitachi
Hitachi E-102SN installation manual

Murata
Murata GRM0335C1E1R9CA01 Series Reference sheet

Murata
Murata GQM1885C2A5R6CB01 Series Reference sheet

Murata
Murata GRM155R60J823KA01 Series Reference sheet

Hubbell
Hubbell HBLP7FS installation instructions

Jung
Jung FM 1701 Series operating instructions

Metrohm
Metrohm Autolab Installation description