Oil Debris Sensor
earDetect
W
gillsc.com
© 2023 Gill Sensors & Controls Limited
Fitting the sensor head
• Fitting the sensor to the equipment requires a thread adaptor available separately from Gill sized
to t the thread size of the equipment and is mandatory for all installations.
• Secure the thread adaptor into the equipment then t the sensor head using the grub screws
provided. Detailed steps to tting the sensor head are contained in the Quick Start Guide
available with the adaptor and should be observed prior to installation.
• Where an NPT tting is to be used, Gill recommend downloading the WearDetect software
from www.gillsc.com/support, restoring the factory defaults in the sensor menu to the “Small
sensitivity”settings and resetting the sensor head by pressing the zero/tare prior to use. Details
can also be found in WearDetect manual.
Parameter
Sensitivity Scale
Small
Water Contamination / Temperature Channel Water Contamination (alarm)
Inhibit Outputs During Conguration Switched O
Disable Fine Channel Switched O
Disable Coarse Channel Switched O
Disable Water Contamination / Temperature Channel Switched O
Parameter Sensitivity Scale
Small Meduim Large
100% FSD Coarse 1 x 3mm Chrome steel ball bearing 1 x 5mm Chrome steel ball bearing 4 x 5mm Chrome steel ball bearing
100% FSD Fine 0.1g ironpowder 0.25g ironpowder 0.5g iron powder
Note: Ensure the equipment the sensor head is tted into is grounded. See the Weardetect User
Manual for more details.
Factory default settings
• From the factory the sensor is set to the small sensitivity scale (see below) for debris size for the Fine
and Coarse debris channels. The sensor can also be set to sense temperature or water presence,
either as an alarm or continuously. From the factory, the sensor will sense water presence as an
alarm.
• In addition, there are a number of sensor functions (see below) that can be enabled or disabled
through downloading the software from www.gillsc.com but the following highlights the default
settings without any software changes.
Note: whilst defaults are included, Gill strongly recommend calibrating the sensor and thresholds to
your application
After Sales Support
Should you require after sales assistance with this product, please go to gillsc.com/product-support.
Alternatively, call us during UK oce hours on 01590 613900 (UK). Please have details of the product and
serial number whenever possible.