manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Gilson
  6. •
  7. Water Pump
  8. •
  9. Gilson Minipuls 3 User manual

Gilson Minipuls 3 User manual

High Performance
Peristaltic Pump
World Wide Web: www.gilson.com
E-mail: [email protected], [email protected], [email protected]
World Headquarters
Gilson, Inc.
3000 W. Beltline Hwy., P.O. Box 620027, Middleton, WI 53562-0027, USA
Telephone: (1) 800-445-7661 or (1) 608-836-1551 • Fax: (1) 608-831-4451
Gilson S.A.S.
19, avenue des Entrepreneurs - BP 145, 95400 Villiers le Bel, France
Telephone: (33) 1-34-29-50-00 • Fax: (33) 1-34-29-50-20
LT800443E. Printed in France, May 2003. Specifications subject to change without notice.
Gilson, Inc., Gilson S.A.S., and Cyberlab, Inc. are ISO certified. ISO 9001 Certified
Ordering Information
Gilson’s Minipuls 3 is available as two parts: a speed control module and a pump head.
An accessory package is suplied with the speed control module.
Item Reference N°
Speed-Control Module F155001
R1 Pump Head F117604
R2 Pump Head F117800
R4 Pump Head F117606
R8 Pump Head F117608
R2/HF (high-flow) Pump Head F117830
R4/HF (high-flow) Pump Head F117831
Te chnical Specifications
Flow Rate Standard Model: 0.3 µL/min to 30 mL/min (72 psi/5 bar/0.5 MPa max)
High Flow Model: 1 mL/min to 220 mL/min (42 psi/3 bar/0.3 MPa max)
Pump Head Standard Model: 1,2,4 or 8 channel heads with 10 stainless steel rollers per head
High Flow Model: 2 or 4 channel heads with 5 stainless steel rollers per head
Head Speed Continuous adjustment from 0 to 48 rpm by 0.01 rpm increments
up to 9.99 rpm and by 0.1 increments above 10 rpm
Peristaltic Tubing Diameter Standard Model: 0.25 to 4 mm (i.d.)
High Flow Model: 2 to 8 mm (i.d.)
Tubing materials PVC for most applications, Viton for chemical inertness, silicone for biocompatibility,
and Pharmed(r) for FDA and USP class 4.
Motor Speed Stability 0.5% for any variation of line voltage, torque or temperature
Line Voltage 90V to 132V for 110 voltage selection: 180V to 264V for 220 voltage selection
Line Frequency 47 to 63 Hz
Power Consumption Full load 45 W at 220V; no load 35 W at 220V
Operating Temperature 0-40° C No warm-up time required
Input/Output Options Contact Closure: Two TTL-compatible inputs for control of start/stop and direction of flow
Voltage Input: One 5 V analog signal for variable control of motor speed
Serial: Gilson Serial Input/Output Channel (GSIOC), an RS-422A interface
Keypad functions Start, stop, direction of flow, increase and decrease flow, prime.
Dimensions (w x h x d) 15 x 18 x 17.5 cm (5.0 x 7.1 x 6.9 in)
Weight 4 kg (9 lbs)
... wide range of flow-rates,
Gilson robustness and reliability!
High performance liquid transfer ...
Minipuls 3 Series
Peristaltic Pumps
3V MP3 10/06/03 17:27 Page 1
Minipuls 3 Series ...
... the peristaltic pump, best performance!
Pulse Free Liquid Transfer
• By driving the liquid flow with as many as
10 rollers, Minipuls 3 is able to produce smoother,
pulse free flows, with excellent accuracy and
precision, even at high flow rates.
• An adjustable speed stepper
motor and high quality precision-
bore tubing assure reproducible
flow rates.
• The adjustable cams allow the
tubing to be overcompressed to
make priming easier or less
compressed to allow the tubing to
last longer. Also, by this means,
minor adjustments in flow rate
are possible, which may be useful
when you want to synchonize
the flow-rates of multichannel
systems.
Wide Flow-rate Range (0.3 µL/min to 220 mL/min),
Wide Tubing Size Range (0.25 mm to 8 mm ID)
Choice of 6 fully interchangeable pump-heads
to accomodate a wide range of flow-rates and back
pressures, according to your application.
So, you do not need to change the entire pump if
your application or flow-rates requirements change.
• Standard flow pump-heads: choice of 1, 2, 4,
or 8 channels.
• High flow pump-heads: choice of 2 or 4 channels.
A wide range of accepted tubing types and sizes
gives you much greater flexibility in terms
of the flow rate range that is available with each
pump head.
• Standard model:
from 0.3 µL/min to 30 mL/min
(maximum pressure 0.5 MPa).
• High flow:
from 1 mL/min to 220 mL/min
(maximum pressure 0.3 MPa).
Gilson Product,
Quality Built-in
Reliable, Robust, Safe
Solidly constructed from robust, chemically resistant
materials, Minipuls 3 ensures reliable liquid transfer
even in the most challenging environments.
The built-in overflow is your protection in case of
tubing rupture.
Quiet, User Friendly
Minipuls 3 is easy to install, simple to operate, easy
to maintain.
Simple operation thanks to its microprocessor
control, uncomplicated soft-touch keypad and
easy-to-read LCD screen.Remote control is possible
with most instruments possessing an RS232C
interface (adapter required).
Snappy Tubing
Changes
Just snap the cams! Tubing in any channel can be
changed easily and independently. The retaining
stops, which are color coded for easy recognition
of the tubing’s internal diameter, ensure that the
tension in the peristaltic tubing is correct and that
reproducible flow rates are obtained.
Gilson Support
With its wide range of experience as a manufacturer
of laboratory equipment for liquid handling, Gilson
can provide support and advice on the best tubings
and connectors to use for your application.
3V MP3 10/06/03 17:44 Page 2

Other manuals for Minipuls 3

3

Other Gilson Water Pump manuals

Gilson Minipuls 3 User manual

Gilson

Gilson Minipuls 3 User manual

Gilson Minipuls 3 User manual

Gilson

Gilson Minipuls 3 User manual

Gilson 322 User manual

Gilson

Gilson 322 User manual

Popular Water Pump manuals by other brands

Graco Hydra-Clean 1040 Operation

Graco

Graco Hydra-Clean 1040 Operation

Jet 668197 installation guide

Jet

Jet 668197 installation guide

Agrowtek AgrowDose Use and maintenance instructions

Agrowtek

Agrowtek AgrowDose Use and maintenance instructions

BUSCH Mink MV 0502 B instruction manual

BUSCH

BUSCH Mink MV 0502 B instruction manual

Lowara Ecocirc XL Series Installation, operation and maintenance manual

Lowara

Lowara Ecocirc XL Series Installation, operation and maintenance manual

Grundfos CR 95 Service instructions

Grundfos

Grundfos CR 95 Service instructions

Stancor SEW Series Installation, operation and maintenance manual

Stancor

Stancor SEW Series Installation, operation and maintenance manual

Chicago Pneumatic CP 0010 Safety and operating instructions

Chicago Pneumatic

Chicago Pneumatic CP 0010 Safety and operating instructions

Villager TERRA 12 manual

Villager

Villager TERRA 12 manual

Flotec E75STVT owner's manual

Flotec

Flotec E75STVT owner's manual

Graco Python A25177 instructions

Graco

Graco Python A25177 instructions

Anest Iwata ISP-250C Series instruction manual

Anest Iwata

Anest Iwata ISP-250C Series instruction manual

Vogelsang VX186QDM2 operating instructions

Vogelsang

Vogelsang VX186QDM2 operating instructions

DAB KC Series Instruction for installation and maintenance

DAB

DAB KC Series Instruction for installation and maintenance

DAB CP Instruction for installation and maintenance

DAB

DAB CP Instruction for installation and maintenance

Zoeller 1461-0006 manual

Zoeller

Zoeller 1461-0006 manual

Toyota IPUP T100L instruction manual

Toyota

Toyota IPUP T100L instruction manual

Ingersoll-Rand ARO 612041 Series Operator's manual

Ingersoll-Rand

Ingersoll-Rand ARO 612041 Series Operator's manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.