32000225229A
Instructions for Use
Introduction
Pleasereadthese instructions andfollowthem carefully forthe
safe and economical use of your boiler.
The Micron series are fanned flue boilers designed to provide
central heating and indirect domestic hot water.
The boiler is fully automatic in operation having only one user
control, the temperature control.
WARNING. It is important that the case is not disturbed or
removed other than for servicing by a competent person.
Gas Leak or Fault
If a gas leak or fault exists or is suspected, the boiler must be
turned off, including the electrical supply and must not be used
until the fault has been put right.
Advice/helpshouldbeobtainedfromyour installation/servicing
company or the local gas undertaking.
Electrical Supply Failure
Failure of the electrical supply will cause the burner to go out.
Should this occur, operation of the appliance will normally
resume after the electrical supply is restored.
If the boiler does not relight after an electrical supply failure the
overheat safety cutoff device may need resetting, as indicated
by illuminated reset light. Open the controls cover and turn
temperature control to “0” (anticlockwise) and then back to
original position, refer to diagram 9.1.
Note: If the boiler is switched OFF, manually, wait at least 30
seconds before switching on again.
Safety Temperature Limiter
IfthesafetyTemperatureLimiteroperatesonanyotheroccasion
than an electrical supply failure, follow the procedure as in
“ElectricalSupplyFailure”. If the overheatoperatesagain, turn
theapplianceoffandcontactyourinstallation/servicingcompany.
Protection Against Freezing.
In this boiler there is a built-in frost protection, which will cause
theboiler, when it is switchedoff at the control knob,to operate
in the event of the water temperature in the boiler dropping to
6oCor7oC. Theboilerwillswitchoffagainwhenthetemperature
of the water in the boiler reaches about 15oC.
Note:Thefrostprotectionwillnotoperateiftheelectricalsupply
is turned off.
If the boiler is to be out of use for any long period of time during
severeweatherconditionswerecommendthatthewholeofthe
system, including the boiler, be drained off to avoid the risk of
freezingup. Makesurethat,iffitted,theimmersionheaterinthe
cylinder is switched off.
Maintenance
To ensure the continued efficient and safe operation of the
boiler it is recommended that it is checked and serviced as
necessary at regular intervals. The frequency of servicing will
depend upon the particular installation conditions and usage,
but in general once a year should be enough.
If this appliance is installed in a rented property in the UK there
is a duty of care imposed on the owner of the property by the
current issue of The Gas Safety (Installation and Use)
Regulations, Section 35.
It is the law that any servicing is carried out by a competent
person.
To obtain service, please call your installer or Heatcall (Glow-
worm’sownServiceOrganisation)usingthetelephonenumber
given on the front cover of these instructions.
Please be advised that the ‘Benchmark’ logbook should be
completed by the installation engineer on completion of
commissioning and servicing.
All CORGI Registered Installers carry a CORGI ID card, and
have a registration number. Both should be recorded in your
boilerLogbook. YoucancheckyourinstallerisCORGIregistered
by calling CORGI direct on :- 01256 372300.
Cleaning
WARNING. Thisappliancecontainsmetalparts(components)
and care should be taken when handling and cleaning, with
particular regard to edges.
Clean the casing occasionally by wiping it over with a damp
cloth or dry polishing duster.
Do not use an abrasive cleaner.
To Light the Boiler
WARNING. Sealed Systems
A sealed water system must be filled and pressurised by a
competent person.
Onlylighttheboilerwhenyouaresurethatthesystemhasbeen
filled and pressurised.
Thepressuregauge should showatleast 0.7bar, anythingless
thanthisfigurecouldindicatealeakandyouMUSTcontactyour
installation/servicing company.
If there is any doubt about the boiler being full of water consult
your installation/servicing company.
ALL SYSTEMS.
Turn the electrical supply on to the boiler and check that all
remote controls are calling for heat. Check also that the
programmer (if fitted) is in the “ON” mode.
To Turn the Boiler On
Open the controls cover, see diagram 9.1.
Turnthecontrolknobclockwisetoanypositionbetween“O”and
MAX. The maximum temperature setting is approx. 82OC
(180OF), see diagram 9.1.
The boiler lighting operation is now automatic as follows:
The fan will operate for 10 seconds prior to the start of the
ignitionsparks,thegasvalvesolenoidswillopenandtheburner
will light. This is shown by the "Burner Lit" LED on the control
panel lighting up.
The burner will remain alight until switched off by the control
thermostat, any remote control or the programmer.
Note: If the boiler is switched OFF, by hand, wait at least 30
seconds before switching on again.
When the boiler switches off, the boiler will go out.
The automatic lighting sequence will operate again when heat
is required.
Shut the controls cover.
It should be noted that this is a fan flue appliance and fan
operation may be heard.
To Turn the Boiler Off
Forshortperiods,turnthecontrolknobanti-clockwiseto“0”Off.
Torelight,turnthecontrolknobtoany positionbetween“0”and
“MAX”.
For longer periods, turn the control knob fully anti-clockwise to
“0” Off and switch off the electrical supply to the boiler.
To relight follow the lighting sequence given above.
Programmer
An optional programmer is available, which will automatically
switch your central heating system on and off once or twice a
day at whatever times you choose.
Note: If the programmer is manually switched on then off when
the boiler is cold, the boiler may continue to operate for about
30 seconds before switching off.