Introduction
Bar code technology enables efficient data collection in
various businesses including both commercial office and
industrial automation﹒Importantly﹐bar code technology
also ensures the accuracy of captured data﹒The bar code
readers described in this manual have been developed for
maximum efficiency﹐accuracy and ease of use in various
process scenarios﹒
FCC Statement
The federal communications commission﹙FCC﹚requires
that all CCD readers must be labeled with FCC
approval﹒
This equipment complies with the requirements in part 15
of FCC rules for a class A computing device﹒These
limits are designed to provide reasonable protection
against harmful interference when the equipment is
operated in a commercial environment﹒This equipment
generates﹐uses and can radiate radio frequency energy
and﹐if not installed and used in accordance with the
instruction manual﹐may cause harmful interface to radio
communications﹒Operation of this equipment in a
residential area may cause unacceptable interference to
radio and TV reception requiring the operator to take
whatever is necessary to correct the interface﹒
1

TABLE OF CONTENTS
Page
Introduction--------------------------------------------- 1
Contents------------------------------------------------- 2
Chapter 1. Technical Data----------------------------- 3
Chapter 2. How to install your Bar Code Reader-- 4
Chapter 3. Pin Assignment---------------------------- 4~7
Chapter 4. Set up configuration---------------------- 7~8
1.Set Default Configuration------------9
2.Interface Options----------------------10
3.System Type--------------------------- 11
4.Keyboard Wedge Setting-------------12
5.RS-232 Setting------------------------ 13
6.WAND Emulation Setting----------- 14
7.Scanning Control----------------------15~16
8.Turn On Various Bar Code Format---17~18
9.Code Identifier------------------------ 19~20
10.Code 39 Control-----------------------21
11.Interleaved 2 of 5 Control------------22
12.Industrial 2 of 5 Control--------------23
13.Matrix 2 of 5 Control-----------------24
14.Coda Bar/NW7 Control-------------- 25
15.EAN-13 Control-----------------------26
16.UPC-A Control------------------------27
17.EAN-8 Control------------------------ 28
18.UPC-E Control------------------------ 28
19.UPC/EAN Conversion--------------- 29
20.Code 11 Control-----------------------29
21.Code 128 FNC1 GS Control-------- 29
22.MSI Code Control-------------------- 30
23.Telepen Mode--------------------------30
24.Laetus Phamacode Control---------- 30
25.China Postal Code Control---------- 31
26.End of Text Message----------------- 32
27.PC AT Keyboard Nationality--------33~34
28.Set Prefix-------------------------------35
29.Set Suffix-------------------------------35
30.Data Format----------------------------36
31.Other Control--------------------------37
Appendix A: Hexadecimal/Decimal Table-------- 38
Appendix B: Hex and Numeric table---------------39~42
AT Function Key----------------------43~46
2

Chapter 1. Technical Data
This User’s Manual introduces the technical specification
of the bar code readers. The product features are
described in later chapter e.g. installation﹐set-up and
configuration as well as detailed technical specifications.
Main Technical FEATURES
Bar code width
:
75mm
Depth of reading
:
0 to 40mm
Working current
:
Scanning 84mA (with Decoder)
:
Stand-by 14mA
Light
:
Red LED array 660nm
Interface
:
TTL, RS232C, Keyboard Wedge,
WAND, Notebook, USB
Device Selection For
Keyboard Interface
:
PC AT/XT, PS/2 25, 30, 50, 60,
70, 80, Acer 7300, IBM 5550,
Mac, NEC9800
Bar code selections
:
Code39, Code32, CIP39
Coda Bar (CLSI)
EAN-13, UPC-A, EAN-8, UPC-E
(Add on 2 of 5)
MSI/Plessey (UK Plessey )
Code 128 (EAN128)
Code 93
Code 11
Interleaved 2 of 5
Industrial 2 of 5
Matrix 2 of 5
China Postal Code
Telepen
Laetus Phamacode
Keyboard nationality
:
US, French, German, Spanish,
Italian, UK, Swiss, Belgium,
Netherlands, Sweden, Norway,
Denmark, Protugal, Finland,
Slovakia, Japan, Hungary,
Greece, Yugoslavia Cyrillic,
Yugoslavia
3

Chapter 2. How to install your Bar Code Reader
Installation:
Step 1. Turn off the power on your terminal device.
Step 2. Connect the bar code reader to the appropriate
outlet on the technical device depending on the
model / interface cable that you have, e.g.
RS232, PS2, ……….
Step 3. Turn on the terminal device, you will hear the
initial welcome music.
Step 4. The reader is now in stand-by mode.
Chapter 3. Pin Assignment
This bar code reader is designed to be connected via
various cable connections, the pin assignments are listed
as below:
1. Keyboard Wedge:
A. 6 DIN and 5 DIN connector
M F M F
5
2
4
3
1
5
2
4
3
1
2
5
1
3
5
3
1
2
4
6
6
4
1
10
Phone
Jack DIN-6M DIN-6F Function DIN-5M DIN-5F
1 3 3 GND 4 4
2 4 4 VCC 5 5
3 -- 5 K/B CLK -- 1
4 -- 1 K/B DATA -- 2
5 1 -- SYS DATA 2 --
6 5 -- SYS CLK 1 --
7 -- -- -- -- --
8 -- -- -- -- --
9 -- -- -- -- --
10 -- -- -- -- --
3 3 GND shield 4 4
4

2. RS-232 : 9 PIN and 25 PIN female RS-232 connector
9P 25P
9
5
6
1 13
25 14
1
Phone Jack 9 Pin (F) 25 Pin (F) Function
1 5.1 7.1 GND
2 9 16.25 VCC
3 -- -- K/B DATA
4 -- -- K/B CLK
5 -- -- SYS DATA
6 -- -- SYS CLK
7 7 4 CTS
8 2 3 TXD
9 8 5 RTS
10 3 2 RXD
5 7 GND Shield
3. WA N D E m ul a t i o n:9 PIN female and 5 DIN、6 DIN
male connector
9P M M
5
24
3
1
5
24
6
3
1
1
9
5
6
Phone
Jack Remark Dsub
9P (F)
Dsub
9P (M) DIN-5M DIN-6M
1 GND 7.8 1 3 3
2 VCC 9 5 1 1
8 DATA 2 7 2 2
GND Shield 7 1 3 3
5

4. Apple MACINTOSH:4 PIN female and 4 DIN male
connector
M F
3
1
4
2
1
3
2
4
Phone Jack Function DIN-4M DIM-4F
1 GND 4 4
2 VCC 3 3
3 K/B DATA -- --
4 K/B CLK -- --
5 SYS DATA 1 1
6 SYS CLK -- --
7 -- -- --
8 -- -- --
9 -- -- --
10 -- -- --
GND Shield 4 4
5. NEC 9800:8 PIN female and 8 DIN male connector
M F
6
4
3
1
7
8
5
2
6
3
4
1
7
8
5
2
Phone Jack Function DIN-8M DIM-8F
1 GND 2 2
2 VCC 8 8
3 K/B DATA -- 4
4 K/B CLK -- 3
5 SYS DATA 4 --
6 SYS CLK 3 --
7 -- -- --
8 -- -- --
9 -- -- --
10 -- -- --
Reset 1 1
Retry 5 5
-- 6 6
-- 7 7
GND Shield 2 2
6

6. TTL (CMOS):9 PIN female and 5 DIN、6DIN male
connector
9P
9
5
6
1
Phone Jack Function Dsub 9P (F)
1 GND 7
2 VCC+5V 9
3 DATA 1
4 INDICATOR 2
5 TRIGGER 3
6 ENABLE 4
7 SCAN 5
8 -- --
9 -- --
10 -- --
GND Shield
Chapter 4. Set Up Configuration
1. Example:
In order to setup the program for the bar code
reader, you must be familiar with the setup
procedure. Three examples are given below.
Example 1:Setup Code 39 refer page 21
Start →Place command to CCD
Code 39 ON →Turning on Code39 decoding
Full ASCII →Code39 Full ASCII mode selected
Verify Checksum →Code39 mode 43
END →Setting procedure completed
7

Example 2:
Start →Place command to CCD
Flash mode →Turning on Flash mode
Start →Place command to CCD
Flash On/Off →Turn on Flash on/off time setting
Appendix A "0",”6” →Setting Flash on 0.6 sec
Appendix A "0",”A” →Setting Flash off 1 sec
Example 3:
Start →Place command to CCD
Interleaved 2 of 5 On →Turning on Interleaved 2 of 5
Define length →Define interleaved 2 of 5
Appendix A "0","A"→Length with is equal to 10
Appendix A "0","C"→Length with is equal to 12
SET Only length 10 is set
Appendix A "0","E"→Length with is equal to 14
All 3 length (10,12,14) are set
completely.
No need to scan “SET” again.
SET Both length 10 & 12 are set
You will be able to read the interleaved 2 of 5 code length
which is equal to 10, 12, 14 digits only.
All Appendix A are no need to scan “END”
8

1. SET DEFAULT CONFIGURATION
Default
All programmed settings will be returned to the
manufacture default setting after the scanning process.
Other available option
Show configuration Show version
Abort setting
Start up code
If the scanner’s light is on, but it can not read. Try to
scan the “start up code”. The scanner may read again.
9

2. INTERFACE OPTIONS
Start
*Keyboard
AT Notebook
RS-232
WAND
End
Read the interface selection code for your particular
application.
Above interfaces, only one can be enabled, other
interfaces will be disabled automatically, ie, scan
“Start”→“RS232”→“End”.
Mute
If you scan “Mute”, the initial welcome music will be
on “Mute” mode when power on the terminal device
10

3. SYSTEM TYPE
Start
Apple Macintosh ADB PC XT
NEC 9800 *PC AT, PS/2 50 60 70 80
IBM 5550 PS/2 25 30
ACER 7300
End
Other system types may be available upon request,
please consult your supplier for details.
11

4. KEYBOARD WEDGE SETTING
Start
*On
Upper/Lower
case
Upper *Lower
Number Keys
*Alphanum Numberlock
Upper Caps
Lock
*OFF ON
Alt+Number
*OFF ON
End
12

5. RS-232 SETTING
Start On
Baud Rate
1200 *9600
2400 19200
4800 38400
Data Bits
7bit *8bit
Parity
*Disabled Even
Odd
RS-232 Hand
Shaking
*Disabled Xon/Xoff RS232
End RTS/CTS RS232
13

6. WAND EMULATION SETTING
Start
On
Bar
High / Low
*High Low
Scan Speed
Highest
*High
Low
Lowest
End
14

7. SCANNING CONTROL
Start
Type LED Light Bar Code
On-with button pressed
Off-with button depressed One bar code
Trigger pressed
On-for 3 seconds
Off-any bar code scanned One bar code
*Trigger on
On-with button pressed, light
on for 3 seconds
Off-with button pressed again
One bar code
Trigger on/off
On-for 30 seconds
Off-automatically after 30
seconds or button pressed
again
One bar code
Trigger on 30 sec.
On-for 120 seconds
Off-automatically after 120
seconds or button pressed
again
One bar code
Trigger on 120 sec.
On-all the time
Off-never off One bar code
LED on
15

On-all the time
Off-never off or trigger off
Saft time Default value is 1 sec
Same bar code
Continuous
read
Continuous reading
Scan “Start”+ “Safety time”+
Appendix A “0”, “8”
Set value is 0.8 Sec
Safety time 0.8
Sec
Safety time setting
After turn ON or finish
reading Barcode will
continue on 60 sec than Flash
Flash Mode Default On 0.3sec,Off 0.2sec
Scan “Start”→“Flash on/off
time” AppendixA→“0”,“A” ,
“0”, “6” the flash on 1 sec,
flash off 0.6sec.
Flash on 1 sec
Flash off 0.6
sec.
Flash on/off time Flash on/off range 0.3~25.5sec
Light on time 3
Sec
Auto Scan
Scan “Start”+ “Auto Scan”+
Appendix A “0”, “3”,
Set light on is 3 sec (Default).
Auto scan will be light on
range 3sec to 255sec
16

8. TURN ON VARIOUS BAR CODE FORMAT
Start
OFF ON
Code 39*
*Interleaved 2 of 5
*Industrial 2 of 5
*Matrix 2 of 5
Coda Bar*
EAN-13*
UPC-A*
EAN-8*
UPC-E*
17

OFF ON
*EAN/UPC
Add-on 2/5
Code 128*
Code 11*
*MSI/Plessey
*Telepen
*China Postal
Code
*Code 93
*Laetus
Phamacode
All Barcodes
Turn Off Turn On
(expect Laetus
Phamacode)
End
18

9. CODE IDENTIFIER
Start
AIM
*Off On
USER
Code39 Interleaved2of5
Industrial 2 of 5 Matrix 2 of 5
CodaBar EAN-13
EAN-8 UPC-E
Code11 MSI
19

Code 128 Code 93
Plessey TELEPEN
UPC-A
Please refer the Appendix B-ASCII table for the ID
character you need, for example:scan appendix A “5”
“3” for S or scan “5” “0” for P.
There is only one code identifier allowed on the
specific type bar code.
End
20
Table of contents
Popular Barcode Reader manuals by other brands

Unitech
Unitech MS842RB quick start guide

Datalogic
Datalogic Magellan 1100i Product reference guide

VSDIGITAL
VSDIGITAL V31 user manual

Infinite Peripherals
Infinite Peripherals LINEA PRO 6 How to use

Area Imager
Area Imager IG610/BT Configuration guide

Leuze electronic
Leuze electronic BCL500i series Technical description