This air conditioner meets strict safety and operating
standards. The installer of this unit must install or service
this unit so it operates safely and efficiently.
The lightning flash with arrowhead symbol,
within an equilateral triangle is intended to
alert the user to the presence of uninsulat-
ed dangerous voltage within the product’s
enclosure that may be of sufficient magni-
tude to constitute a risk of electric shock to
persons.
The exclamation point within an equilateral
triangle is intended to alert the user to the
presence of important operating and main-
tenance (servicing) instructions in the liter-
ature accompanying the appliance.
Contact Installer if Necessary:
The installation instructions are for a experienced
installer. If you are not an experienced installer, contact a
local installer for help. If you require help with service,
contact your certified dealer or Daewoo Electronics for
additional instructions.
If Unit is Installed Improperly:
The manufacturer shall in no way be responsible for
improper installation or maintenance service, including
failure to follow the instructions in this manual.
Precautions When Wiring:
• Do not plug in the unit until all connections (tubing,
drain hose, mounting, etc.) have been made and dou-
ble-checked.
• High voltages are present in this unit and are very dan-
gerous. Please refer to these instructions and diagrams
when wiring. Improper connections or inadequate
grounding can cause accidental injury.
• This unit must be grounded in accordance with local
electrical codes.
• Connect wires and pipes securely and tightly as loose
connections/wiring may cause overheating at connec-
tions and a possible fire hazard.
Precautions When Transporting:
• When transporting the unit, be very careful and get help
as the units are very heavy. Be careful of sharp edges
on the units also.
Precautions When Installing:
• When installing in a ceiling or wall, make sure the
ceiling/wall is strong enough to hold the unit’s weight. A
frame may be necessary for added support.
• When installing in a room, make sure the tubes are
well insulated to protect the walls and furniture from
sweating of the tubes.
• When installing in moist or uneven locations, make
sure to use a raised level concrete pad or concrete
blocks to provide a level, solid foundation for the out-
door unit; this prevents water damage and vibration.
• When installing in an area of high winds, make sure
to securely anchor the outdoor unit down with bolts and
a metal frame.
When Connecting Refrigerant Tubing:
• Keep all tubing as short as possible.
• Use the flare method for connecting tubing.
• Apply refrigerant lubricant to the matching surfaces of
the flare and union tubes before connecting them, then
tighten , making sure not to overtighten.
• Check the tubes carefully for leaks before starting the
test run.
When Servicing:
• Make sure the power is off and the unit is unplugged
before opening the unit to troubleshoot or repair electri-
cal parts and wiring.
• Keep your fingers and clothing away from any moving
parts.
• Clean up the sight after you finish, making sure no
metal scraps and wiring are left in the unit.
• The Air conditioner shall be installed in accordance with
the nationed wiring regulation.
SAFETY INSTRUCTIONS
1
PLEASE READTHE FOLLOWING SAFETY INSTRUCTIONS BEFORE
INSTALLING AND OPERATINGTHE UNIT:
IMPORTANT NOTES
•Adhere to all safety instructions and warnings
throughout this manual.
• Read this manual carefully before installing or operat-
ing this unit to become familiar with its features and
obtain the performance that will bring you continued
enjoyment for many years.
• Follow each installation or repair step exactly as
shown in the manual.
• Observe all local, state and national electric codes.
Contact your local government for more information
on electrical codes.
WARNING:
• ELECTRICAL SHOCK CAN CAUSE SEVERE PERSON-
AL INJURY OR DEATH. ONLY A QUALIFIED, EXPERI-
ENCED ELECTRICIAN/INSTALLER SHOULD ATTEMPT
TO WIRE THIS SYSTEM.
• THE APPLIANCE IS NOT INTENDED FOR USE BY CHIL-
DRENOR INFIRM PERSONS WITHOUT SUPERVISION.
•YOUNG CHILDREN SHOULD BE SUPERVISED TO
ENSURE THAT DO NOT PLAY WITH THE APPLIANCE

CONTENTS
2
It is recommended that you read the Installation and Operating instructions fully before installing and/or operating this
unit.
Safety Instructions...............................................................................................................................................................1
Contents ..............................................................................................................................................................................2
Basic Accessories ...............................................................................................................................................................3
Optional Accessories...........................................................................................................................................................4
Location of Controls.............................................................................................................................................................5
Indoor Unit....................................................................................................................................................................5
Outdoor Unit.................................................................................................................................................................5
Remote Controller........................................................................................................................................................7
Remote Display............................................................................................................................................................7
Operation.............................................................................................................................................................................8
Connecting the AC Cord..............................................................................................................................................8
How to Install Batteries ................................................................................................................................................8
Setting the Unit for Remote Operation.........................................................................................................................8
Celsius to Fahrenheit Conversion Chart......................................................................................................................9
To Set Auto Mode........................................................................................................................................................9
To Set Quick Mode ....................................................................................................................................................10
To Set Cool Mode......................................................................................................................................................10
To Set Fan Only Mode...............................................................................................................................................11
To Set Dehumidifier Mode.........................................................................................................................................11
To Select the Fan Direction .......................................................................................................................................12
To Set On Timer Mode ..............................................................................................................................................13
To Set Off Timer Mode ..............................................................................................................................................13
To Set Sleep Mode ....................................................................................................................................................14
To Set Turbo/Mild Mode ............................................................................................................................................14
Emergency Operation................................................................................................................................................14
Changing/Cleaning the Air Filters .....................................................................................................................................15
Cleaning the Indoor Cover................................................................................................................................................15
Installing the Remote Bracket...........................................................................................................................................16
Care and Maintenance......................................................................................................................................................16
Troubleshooting Guide......................................................................................................................................................17
Specifications ....................................................................................................................................................................18

This Installation section explains how and where to connect this new air conditioner. Please read make sure all acces-
sories are included as shown below and read manual thoroughly. This Installation section is provided to assist the per-
son knowledgeable in air conditioner installation and should not be installed by anybody who is not thoroughly familiar
with this type of installation. Please contact a professional installer if necessary.
ACCESSORIES SUPPLIEDWITHTHE UNIT:
COPPERTUBING:
Copper tubing supplied is available at most dealers or A/C shops. Make sure the new copper tubing has the exact same
specifications and diameter as the original copper tubing and is as short as possible.
BASIC ACCESSORIES
3
ON OFF ENTER CANCEL
TIMER RESET
SWING
FAN SPEED
MODE
SLEEP
ON/OFF
TEMP.
12
8
679
3
10
11 12
5
4
No. Description Qty.
1 Wall Bracket 1
2 Outdoor Unit Cover 1
3 Remote Controller 1
4 Deodorizing Filter 1
5 Electrostatic Filter 1
6 Remote Holder 1
No. Description Qty.
7 Foot Cushion 4
8 Concrete Nails 5
9 Remote Holder Screws 3
10 Wall Bracket Screws 8
11 Wall Cap 2
12 Battery 2

OPTIONAL ACCESSORIES
4
1 2
4
3
5 76
ACCESSORIES NOT SUPPLIEDWITHTHE UNIT:
No. Description Part No. Qty Material Size
1 Drain Hose Extension 3103200400 1 ID19.6 X 2m PVC Pipe
2 Tape 2TQ1008000 1 PVC 80W X 0.1T X 3.5m
3 Copper Tubing Extension 3100002600 1 1/2", 1/4" Copper Tube
4 Insulator Plate 3103301000 1 F-US 225 X 120 X 8T
5 Putty 2221040001 1 80g
6 Connection Cord 3102796400 1 3P X 6m
7 Signal line Cord 3102796500 1 3P X 6m
Complete Optional 3100400000 1
Accessories (1, 2, 3, 4, 5, 6, 7)
(5160 Heat Only)

5
LOCATION OF CONTROLS
Indoor Cover
Electrostatic Filter
Removes dust
particles from the air.
Deodorizing Filter
Removes bad
smells from the air. Emergency/
Remote Switch
Slide to select
the desired position.
Indicators
Indicate the
AC setting.
Remote Sensor
Power Plug
Air Cleaning
Filters
Removes dust
and prohibits
germs. AIR OUT
Air In
Sensor Wire
(DSB-181LH Only)
Fan Direction
(Up/Down)
Fan Direction
(Left/Right)
ONOFFENTERCANCEL
TIMERRESET
FANDIR.
FANSPEED
MODE
SLEEP
ON/OFF
TEMP.
LCD Remote Controller
INDOOR UNIT
Connection Cover
Remove cover to access the AC connection
to the indoor unit.
Service Valves
The indoor and outdoor units
are connected by copper tubes
which are connected here.
AIR IN
AIR OUT
OUTDOOR UNIT
Table of contents
Popular Air Conditioner manuals by other brands

Fujitsu
Fujitsu ASYG 09 LLCA installation manual

York
York HVHC 07-12DS Installation & owner's manual

Carrier
Carrier Fan Coil 42B Installation, operation and maintenance manual

intensity
intensity IDUFCI60KC-3 installation manual

Frigidaire
Frigidaire FAC064K7A2 Factory parts catalog

Sanyo
Sanyo KS2432 instruction manual

Mitsubishi Electric
Mitsubishi Electric PUHZ-RP50VHA4 Service manual

Panasonic
Panasonic CS-S18HKQ Service manual

Panasonic
Panasonic CS-E15NKE3 operating instructions

Gree
Gree GWH18TC-K3DNA1B/I Service manual

Friedrich
Friedrich ZoneAire Compact P08SA owner's manual

Daikin
Daikin R32 Split Series installation manual