10
AP-7
Italian 30 Watt Integrated Amplifier
Troubleshooting
TroubleshootingTroubleshooting
Troubleshooting
SYNPTOM DESCRIPTION CAUSE REMEDY
SPEAKER HUMMING
PROBLEMS
The speakers hum when the
amplifier is connected to
the system
•The unit is correctly coupled with
the Ground on DC •Be sure your area and personal
environment are well grounded
eventually isolate the ground Pin
of the power chord plug for
verification
CHASSIS VIBRATION The unit features an internal
fan to prevent the protection
shut-off the unit early in
warm environments
• •The fan constantly runs at low
speed and it isolated with soft
silicon Anyway to stop it run it
can be switched out opening the
unit cover and pulling out the
two fan’s pin connector
•The interconnect input and/or
output cables are not shielded •Be sure to always use shielded
cables for unit connections
SWITCHING ON/OFF BUMP The Stage bumps any time
is switched ON or OFF •It is important to notice that it
does not produce any risk even if
the bump is high
•
THE UNIT DOES NOT WORK
WHEN THE STAGE IS
SWITCHED ON
•The AC Stage plug is
disconnected from the AC wall
plug
•Connect it being sure that the
AC wall plug works
•The interconnect cables are not
properly connected to the unit •Connect them properly
•The fuse is blown •Substitute the fuse with one of
the same value
• •Be sure you selected the right
Input on the amplifier
F A Q
F A QF A Q
F A Q
ACTION DESCRIPTION HOW TO ADJUST IT
MATCHING THE AMPLIFIER
IMPEDANCE •Your amplifier can play any
speaker impedance does to
nominal 4
Ω
•The amplifier features 3 different quality protection
eventually mute the amplifier even temporarily to
avoid blowing
CLEANING THE UNIT •The Unit is dirty and needs to be
cleaned •Use ONLY diluted alcohol and a very soft 100%
cotton cloth to sweep dust and stains out
•Any acid or not extremely soft cloth will irreversibly
damage the Stage fine aesthetic
•Do not use any alcohol to clean the unit anodised
label, or printed parts Only dry cloth is allowed
Troubleshooting & F A Q