GOLDENSEA UV UVS4 User manual

1
USER GUIDE

USER GUIDE-WARNINGS
2
Improper use of this product may cause damage to skin and eyes
This device may only be used by trained personnel
Before operating this product the operator must read the user guide
and be aware of all the risks associated with this product and best
practices for using it
Never enter the disinfection area when the product is in operation
and the red LED is illuminated
!
!
!
!
!

AUDIO ALARM
A built in alarm will provide audible
tones to alert users to the different
important events and states the
product is in
VISUAL INDICATORS
Red and Green LEDs will light up
solid or flashing to provide a visual
indication of the product’s state
3
SAFETY BY DESIGN
MOTION SENSOR
Lamp automatically shuts
down if motion is detected

DELAYED START
Audio and Visual indicators during
delayed start to allow operator to
leave the disinfection area prior to
lamp on
AUTO FALL PROTECTION
If the unit senses a larger than 45
degree tilt, power will
automatically turn off to lamp
4
SAFETY BY DESIGN
*
*UVS4, UVP36, UVM216, UVM900, UVAIR216 are fitted with this sensor

WARNING SIGN
All units will come with a warning
sign for the operator to place on
the door to the area to be
disinfected
UV GLASSES
All units will come with UV filtering
glasses
5
SAFETY BY DESIGN

6
SAFETY BY DESIGN
!
EVEN THOUGH ALL GOLDENSEA UV PRODUCT HAVE BUILT IN
SAFETY FEATURES IT IS ESSENTIAL THAT ALL OPERATORS AND
COMMERCIAL REPRESENTATIVES UNDERSTAND THE BEST
PRACTICES AROUND USING THESE PRODUCTS!

USER GUIDE-PREPARE
7
!
1. Ensure unit is standing on astable surface or mounted safely to the wall
2. Ensure the disinfection area is clear of LIVING BEINGS PRIOR TO PROCEEDING
3. Ensure you have aclear path to exit the area once unit is activated
4. Ensure you know how much time you have to exit the disinfection area.Different products have different delay
start times.Refer to the Delay Start Time chart on page 27
5. If the door/s to the area to be disinfected have significant gaps around the frame find an item to block the gap
and place it near the door for use on exit
6. Locate the supplied UV protective eyewear and put them on
7. Even though you must never be in the disinfection area when the unit is irradiating, it remains best practice for
the operator to also wear nitrile gloves and tightly woven clothing which covers all exposed skin.
8. Locate the supplied warning sign and hang it on the outside of the exit door
1. If there is more than one entrance/ exit to the disinfection area, place additional signs at these doors
9. Locate the supplied remote control and keep it on you or store it in the remote control pouch affixed to the
warning sign

USER GUIDE-SETUP
8
!
1. Plug the unit into an electrical outlet, do not modify/ alter the electrical
connection of the product in anyway
2. Turn on the product by setting the I/0rocker switch to I. The green LED will
illuminate.The unit is now ready to be programmed.The UVC tubes are NOT
illuminated at this time
3. Where possible use the included remote control and move to the door in
preparation for activation
4. Select the appropriate disinfection time by pressing the relevant button
5. Before pressing start reassess the area, make sure there are no living
beings in the area and that your path to exit is clear

USER GUIDE-ACTIVATE
9
!
1. Press the start button
2. Once the start button is pressed an audible alarm will sound and ared LED light
will flash for the duration of the delayed start time
3. YOU MUST EXIT THE DISINFECTION AREA IMMEDIATELY
4. Once the delayed start time has ended, the tubes will activate and the red LED light
will illuminate for the duration of the disinfection process
5. During emission there will be an audible ping every 10 seconds until the emission
time is over

USER GUIDE-END OF CYCLE
10
!
1. Once the disinfection process has ended, the red LED light will turn off and be
replaced by the green LED light.This will indicate that it is now safe to enter the
room
2. Upon entering the room, open windows to ventilate area
1. You may encounter an unusual smell which is anormal result of the
disinfection process and is not harmful
3. If using amobile product return the unit to its safe storage location
4. Remember to return the UV Warning Sign, Remote control and UV Glasses to their
storage location

USER GUIDE-INTERRUPTION OF
CYCLE
11
!
1. If the disinfection cycle is interrupted due to the motion sensor being activated,
the unit will sound an alarm tone until an operator resets the unit
1. The unit may be reset by selecting the relevant timing cycle followed by the
start button
2. The unit will now go through the delay start process and then begin the cycle
3. You may also restart the unit using the remote control
2. If the disinfection cycle is interrupted due to apower outage, no alarm tone will
sound.Once power returns the disinfection cycle will need to be restarted as per
previous instructions

USER GUIDE-INFO
12
!
1. Unit is most effective when placed in line of sight of surface to be disinfected
2. Ensure placement of unit allows for greatest coverage
3. If necessary add more units at different points in the disinfection area
4. Shaded areas are likely not to be disinfected
5. UVGI disinfection is most effective when added to existing disinfection protocols
6. Best practice is to complete manual disinfection protocols prior to UVGI activation
7. UVGI disinfection alone will not disinfect an entire area

REMEMBER
13
!
NEVER ENTER THE DISINFECTION AREA WHEN THE PRODUCT IS
IN OPERATION, THE ALARM BUZZER IS SOUNDING AND THE
RED LED IS ILLUMINATED
!
!

PRODUCT AUDIO/ VISUAL INDICATORS
14
!
STATUS AUDIO VISUAL
Ready to operate -Green LED-solid
Delayed Start Continuous Red LED-flashing
Disinfection Single ping per 10
seconds Red LED-solid
Motion interruption Dual ping per 10
seconds
Red + Green LED-
flashing
End of cycle Triple ping, 3 times Green LED-solid
Fall protection mode
Quadruple ping per
10 seconds Green LED-flashing
*
* Subject to change

15
AREA/ TIME DISINFECTION CHART
*
5 mins 10 mins 30 mins 60 mins
120 mins
UVS4
- - 1 m22 m24 m2
UV
-BOX^200 cm2200 cm2200 cm2- -
UVP36
- - 10 m220 m240 m2
UVL72
- - 20 m240 m280 m2
UVL150
- - 40 m280 m2160 m2
UVL220
- - 60 m2120 m2240 m2
UVT72
- - 20 m240 m280 m2
UVM216
- - 60 m2120 m2240 m2
UVM900
- - 240 m2480 m2960 m2
*Disinfection Area/ Time calculated based on aroom height of 2.5m and targeting xpathogen.Different variables will result in changed area sizes.Please
consult the GOLDENSEA UV Calculator for more information.
^Box has a surface area 200 cm2and 5mins is enough time destroy/ neutralise all know pathogens at present.Longer disifection times are there for future
use.

16
DELAY START TIME CHART
Delay Start
Time
UVS4
30 seconds
UV
-BOX n/a
UVP36
30 seconds
UVL72
2 minutes
UVL150
2 minutes
UVL220
2 minutes
UVT72
2minutes
UVM216
3 minutes
UVM900
3 minutes

17
END