Avensys
Avensys
95.620.431/ÄM 205474/11.06
34 084
GB .....5

I
Valve Body
Wallplugs Screws
Escutcheons
Filters
Threaded Rings
Flow Limiters
Handshower
Filter
Flexible Hose
Shower Rail
Outlet
Nipple
Plug
Backplate
Table Of Contents Installation Dimensions (mm)
1 2

II
Spare Parts
3 4

5
Index
Spare Parts
Table Of Contents . . . . . . . . . . . . . . . . . 1
Installation Dimensions . . . . . . . . . . . . 2
Spare Parts Drawing. . . . . . . . . . . . 3 + 4
Spare Parts List. . . . . . . . . . . . . . . . . . . 5
Technical Data. . . . . . . . . . . . . . . . . . . . 6
Installation. . . . . . . . . . . . . . . . . . . . . . . 7
Exposed Installation. . . . . . . . . . . . . . . 7
Pipe And Shower Hose Connection. . . 9
Adjustment. . . . . . . . . . . . . . . . . . . . . 10
Maintenance . . . . . . . . . . . . . . . . . . . . 11
Care . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Trouble Shooting . . . . . . . . . . . . . . . . 13
Guarantee . . . . . . . . . . . . . . . . . . . . . . 15
Dear Customer,
Thank you for choosing a GROHE product.
Please follow these instructions carefully
and you will enjoy many years of reliable
service from this fitting.
No. Description Cat.-No. Pack-
ing
unit
9.3 O-ring seal 01 287 10
9.4 Filter 06 768 5
9.5 Escutcheon 00 197 2
10 Handshower 28 261 1
11 Filter 07 002 2
12 Shower rail 28 666 1
12.1 Sliding shower holder 07 659 1
12.2 Shower rail holder 45 362 1
12.2.1 Cover cap 45 363 1
13 Flexible hose 28 161 1
Optional accessory
14 Compensation ring 45 406 1
No. Description Cat.-No. Pack-
ing
unit
1 Handle complete 47 597 1
1.1 Handle fixing 47 058 1
1.1.1 Cap 00 090 1
2 Cover Ring 00 565 1
3 Stop ring 47 593 1
4 Control unit 47 598 1
5 Wax element 00 798 1
6 Slider 07 587 1
7 Seat with spring 47 594 1
7.1 O-ring seal 03 169 5
8 Set screw M5x12 02 125 5
9 Connection elbow 12 111 2
9.1 Flow limiter set 46 428 1
9.2 Non-return valve 06 544 2

6
Technical Data
Functioning Principle
This Avensys mixing valve is a thermostatic
mixer with wax cartridge. Turning the shut-
off handle in a counter-clockwise direction
opens the water flow. Turning the tem-
perature handle in a counter-clockwise
direction sets the temperature from cold to
hot.
This product is supplied with connectors to fit
ø 15mm pipework. Connection should be hot
left, cold right as viewed from the operating
position. The product is preassembled.
Plumbing Systems
This thermostatic mixing valve is suitable for
installation with:
•Gravity-fed plumbing systems with an
open vented hot water cylinder
•Cold water storage cistern
•Mains pressure unvented and instantan-
eous thermal hot water storage systems
•Multi-point gas water heaters
•Combination boilers with a modulating hot
water output
Supply Pipework
Ensure the supply pipework is thoroughly
flushed before installing the mixing valve.
GROHE recommends installing isolating
valves upstream of the mixing valve for
servicing purposes.
New Water Regulations
This GROHE-product should be installed to
comply with the New Water Regulations
covering backflow prevention. It must also
be installed in accordance with local bye-law
requirements.
Specification
•Exposed thermostatic shower mixing
valve, concealed or exposed supplies
•Flow pressure
- Low pressure 0.1 - 1 bar
- High pressure 1 - 10 bar
•Avoid major pressure differences between
hot and cold water supply:
For different supply pressures use
enclosed flow limiters, see chapter
“Exposed Installation” on page 7.
•Max. operating pressure 10 bar
•Max. test pressure 16 bar
•Mixed water flow rate without downstream
resistance:
•Temperature
- Max. (hot water inlet) 80 °C
- Recommended (for economy) 60 °C
- Maximum temperature is reached when
the temperature handle is rotated 270°
in a counter-clockwise direction.
•Water connection cold - RH
hot - LH
Pressure 0.1 0.2 0.3 0.4 0.5 0.6 bar
Flow rate 7.5 10.5 14 17 18.5 21 l/min

7
Installation
Exposed Installation
The thermostatic shower mixing valve can
be installed in two different ways. The mixing
outlet can be at the bottom for use with a
handshower or at the top for use with a
headshower.
If there is a pressure differences between
the hot and cold water supply install
attached flow limiters in the water
connection elbows, see table below.
•Screw out connection elbows (A), see
Fig. [1].
•Install flow limiters (B) in accordance to
table above with threaded rings (C) by
using a 12mm socket spanner.
The thermostatic mixing valve is fixed to the
wall via the backplate and connected to the
supply pipes by a pair of elbows. The elbows
are preassembled to the valve body. The
valve body is fixed to the backplate by a set
screw.
In case of exposed installation with supply
pipes from above or below rotate inlet
elbows 90°and connect to 15mm supply
pipes.
1.Loosely screw on nuts (A1) with com-
pression rings (A2), see Fig. [2].
2.Ensure that the projections of the supply
pipes, (i.e. exposed beyond the wall sur-
face) have the correct length (13 - 18mm)
and distance (150mm).
3.Place the valve body (E) with the elbows
and backplate (D) to the supply pipes.
4.Loosen set screw (D1), see Fig. [3].
5.Remove valve body (E) from supply pipes
and hold backplate (D) in position.
Cold Water
Inlet Warm Wa-
ter Inlet Connection
Cold Warm
0.1 - 1 bar 0.1 - 1 bar without without
1 - 5 bar 1 - 5 bar 7 l (green) 5 l (yellow)
1.5 - 10 bar 0.1 - 0.5 bar 7 l (green) without
> 0.5 bar 7 l (green) 5 l (yellow)
1
B
C
12mm
A
BC
12mm
A
2
D
E
A1A2
3
D
E
D1
2.5mm

8
Installation
6.Mark the holes in the backplate for wall-
plugs, see Fig. [4].
7.Drill the holes (6mm) for the wallplugs (F)
and fit them into the wall, see Fig. [5].
8.Fix the backplate (D) with set screw (D1)
on top or bottom to the wall with
screws (G), see Fig. [6].
9.Slide the escutcheons (H) over the
supply pipes and install filters (J), see
Fig. [7].
10.Slide the valve body (E) with elbows and
compression nuts loosely over the
supply pipes.
The body must touch the backplate. If
not, check pipes for length again.
11.Fix the valve body (E) to the back-
plate (D) by tightening set screw (D1).
Do not use excessive force to tighten
the set screw (D1).
12.Tighten the compression nuts (torque
min. 20 Nm), see Fig. [8].
4
5
F
6
G
D
D1
7
E
2.5mm
D1
HJ
D
8
24mm

9
Installation
Pipe Connection
1.Close free outlet with plug (K), see Fig. [9].
2.Thread the outlet nipple (L) with the O-ring
seal into the valve body outlet.
3.Insert pipe and tighten outlet nipple (L).
Open hot and cold water supply.
Check the pipework and connections to the
thermostat mixing valve for leaks.
For reversed supplies installation the
complete mixing valve must be rotated 180°.
Therefore shut-off handle, temperature
handle, cover ring and stop ring must be
dismounted, rotated 180°and reinstalled.
Shower Hose Connection
1.Close free outlet with plug (K), see
Fig. [10].
2.Remove O-ring seal (L1).
3.Turn outlet nipple (L) 180°and fit O-ring
seal (L1).
4.Thread the outlet nipple with the O-ring
seal into the valve body outlet.
5.Connect flexible shower hose.
Open hot and cold water supply.
Check the pipework and connections to the
thermostat mixing valve for leaks.
For reversed supplies installation the
complete mixing valve must be rotated 180°.
Therefore shut-off handle, temperature
handle, cover ring and stop ring must be
dismounted, rotated 180°and reinstalled.
9
K
L
24mm
24mm
24mm
L
24mm
L1
K
24mm
10
1. 2. 3.
180°

10
Installation
Adjustment
The temperature of the outflowing water is
factory set to 43 °C. A temperature adjust-
ment is necessary if:
•The maximum water temperature
measured at the outlet varies from
the factory set temperature.
•After any maintenance operation on the
thermostatic cartridge.
For temperature adjustment please
proceed as follows:
1.Turn the shut-off handle counter-clockwise
to fully open position and open water flow.
2.Turn the temperature handle counter-
clockwise to maximum hot water
temperature.
3.Lever out cap (M), see fig. [11].
4.Unscrew screw (N).
5.Pull off temperature handle (O).
6.Check the temperature of the outflowing
water with a thermometer, see Fig. [12].
7.Push on temperature handle and adjust
temperature to 43 °C.
Turn clockwise (to reduce temperature)
or counter-clockwise (to increase tem-
perature).
8.Pull off temperature handle (O) and
reinstall in hot water position as described
in Fig. [11] in reversed direction.
11
O
M
N
12
O

11
Maintenance
I. Control Unit
1.Shut off hot and cold water supply!
2.Turn the shut-off handle counter-
clockwise to fully open position and
open water flow.
3.Turn the temperature handle counter-
clockwise to maximum hot water
temperature.
4.Lever out cap (M), see Fig. [13].
5.Unscrew screw (N).
6.Pull off temperature handle (O).
7.Remove circlip (P1) and pull off scale
ring (P).
8.Remove circlips (Q1), washer (Q2) and
pull off shut-off handle (Q).
9.Pull off adapter (R).
10.Pull off cover ring (S) and stop ring (T).
11.Loosen set screw (D1).
12.Unscrew connections and take valve
from the supplies.
13.Screw out control unit (U), see Fig. [14].
14.Take out O-ring seal (U1).
15.Take out wax element (V), slider (W) and
spring (X).
Inspect and clean all parts, replace if
necessary and grease with special valve
grease (ref. No. 18 012).
Reinstall control unit
1.Unscrew seat (Y) with O-ring, see
Fig. [15].
2.Reinstall O-ring seal (U1).
3.By turning the unit stem counter-clockwise
make sure the control unit (U) is in open
position and screw in.
4.Reinstall wax element (V), slider (W) and
spring (X) from behind, see Fig. [16].
5.Close control unit (U) by turning the unit
stem clockwise to closed position.
6.Tighten seat (Y) in the valve body.
S
T
O
2.5mm
24mm
RQQ1
M
N
Q2
P1
D1
13
P
14
XWVU1
46mm
U
15
U
46mm
Y
U1
16
XWV
Y

12
Maintenance
7.Unscrew seat 1/8 to 1/6 turn (45° to
60°), see Fig. [17].
8.Slide valve on the supplies, see Fig. [18]
9.Tighten set screw (D1) and compression
nuts.
10.Push on stop ring (T) with catch (T1)
on top.
11.Reinstall cover ring (S) with mark (S1)
on top.
12.Push on adapter (R).
13.Push on shut-off handle (Q) in closed
position.
14.Reinstall washer (Q2) and fix with cir-
clips (Q1), the smaller one is cloth to the
shut-off handle.
15.Push on scale ring (P) with 0on top and
fix with clip (P1).
16.Reinstall the temperature handle (O) in
position hot water.
17.Fix temperature handle with screw (N)
and cover with cap (M).
Readjustment is necessary after every
maintenance operation on the control unit,
see chapter “Adjustment” on page 10.
II.Non-return valve, see spare parts
drawing on page 3, 4. and Fig. [13].
1.Same procedure as for control unit, see
Fig. [13], points 1, 11 and 12.
2.Unscrew elbow, see spare parts drawing
on page 3 and 4.
3.Remove threaded ring with flow
limiter if installed.
4.Take out and replace non-return
valve.
Reassemble in reverse order.
Only genuine GROHE replacement parts
must be used.
17
45°-60°
18
M
N
S
T
O
2.5mm
24mm
R
T1S1
QQ1
D1
Q2
P1
P

13
Care
Trouble Shooting
We want to ensure that you get long-lasting
satisfaction and pleasure from your GROHE
fitting. Therefore, please read the following
care instructions because damage to the
surface and underlying material resulting
from improper treatment is not covered by
our guarantee.
Do not use any abrasive sponges or scou-
ring agents for cleaning. We also advise not
to use cleaning agents containing solvent or
acid, limescale removers, household vinegar
and cleaning agents with acetic acid. They
are aggressive to the surface and will leave
your fitting dull and scratched. As the for-
mulations of commercially available cleaning
agents frequently change, we cannot gua-
rantee they will provide the gentle care our
fitting deserves.
Clean the fitting with a little soap and a moist
cloth only, then simply rinse off and wipe dry.
You can avoid lime spots by drying the fitting
each time it is used. If lime deposits do oc-
cur, remove them with Grohclean (ref.
no. 45 939), our environment-friendly
cleaning liquid. Grohclean is specially
formulated to gently clean the surface of our
Problem Cause Remedy
Thermostatic valve
opens through hot Hot and cold water supplies have
been connected in reverse Rotate the thermostatic mixing
valve
Range of temperature
adjustment restricted High pressure difference between
hot and cold water supply Install flow limiter see chapter
Exposed Installation
Shower insufficiently
cold or hot Adjustment incorrectly set
Hot water supply temperature too
low
Refer to the instructions in chapter
Adjustment
Check hot water source tempera-
ture setting
No flow of hot or cold
water Either the hot or cold side is not
fully pressurized
Debris caught inside the inlet of
the control unit
Replace non-return valve, refer to
chapter Maintenance
Remove mixing valve and flush out
or remove any debris lodged in-
side the hot or cold inlets or filters
Hot water emerges to
cold water supply or
vice versa
Non return valves are damaged in
cause of lime Replace non-return valve, refer to
chapter Maintenance

14

15
Guarantee
Guarantee declaration
Our products correspond to the valid tech-
nical and water supply standards as well as
the relevant approvals requirements. We
guarantee them to be free of design and
production faults at the time of delivery and
that with correct use and care in accordance
with our printed instructions they will function
reliably.
Guarantee period
- The guarantee is valid in private homes for
5 years from the purchase date. Proof of
purchase has to be provided when making
a guarantee claim.
- By use in commercial or institutional appli-
cations the guarantee is valid for 1 year
after first use. An extension of the
guarantee up to 5 years can be achieved
by showing that the product is
professionally maintained each year.
To make a guarantee claim, proof of pur-
chase or, the beginning of use is required.
The guarantee period is not renewed or in-
creased through supply of spare parts or
repair during the guarantee period. The
guarantee period for purchased spare parts
is the same as for original products.
Guarantee performance
A)During the whole guarantee period we will
correct all functional defects for which we
are responsible (limitations see E + F).
B)It is our option if we correct the defects by
repair or replacement.
C)During the above guarantee period we will
not charge for the cost of parts, travel,
working time, freight and packaging
needed to effect the correction of defects.
D)If we are not able to correct the defect we
are prepared to supply a replacement
product.
E)Deliberate or careless damage is not co-
vered by this guarantee. If the installation,
assembly or care instructions that were
valid at the time of installation are not fol-
lowed or the product is used for a purpose
other than that given in the written infor-
mation the guarantee declaration does not
apply. Problems caused by dirt, limescale
or aggressive cleaners are not covered by
the guarantee.
F)The guarantee becomes void if repairs are
not carried out competently or spare parts
of non GROHE origin are used.
G)Replaced parts become the property of
GROHE and are to be surrendered to our
service personnel or sent to our registered
offices.
Please enter date of purchase and installation here. Our address
GROHE Limited
1, River Road
Barking,
Essex, IG11 OHD
GB
Tel.: +44 208 5947292
Fax: +44 208 5948898
GROHE Deutschland
Vertriebs GmbH
D-32457 Porta Westfalica
Tel.: +49 571 3989-333
Fax.: +49 571 3989-999
Table of contents
Other Gröne Kitchen & Bath Fixture manuals

Gröne
Gröne Talia 20 892 User manual

Gröne
Gröne 49 113 User manual

Gröne
Gröne GET E 36366001 User manual

Gröne
Gröne GROHTHERM CUBE 34 497 User manual

Gröne
Gröne Concetto 32 253 User manual

Gröne
Gröne GROHTHERM 2000 SPECIAL 34 202 User manual

Gröne
Gröne K7 31 380 User manual

Gröne
Gröne 31 380 User manual

Gröne
Gröne K4 User manual

Gröne
Gröne 27 641 User manual
Popular Kitchen & Bath Fixture manuals by other brands

Lefroy Brooks
Lefroy Brooks CW-4624 Installation, operating, & maintenance instructions

Luxart
Luxart Lumino LUM241-PU Installation

Brizo
Brizo Vesi T6740 manual

Zomodo
Zomodo KTC013 User instruction

Hans Grohe
Hans Grohe C71-F450-06 43201 Series manual

Hans Grohe
Hans Grohe M7115-H320 ST Instructions for use/assembly instructions