Graco 185-493 Datasheet

INSTRUCTIONS–P
ARTS LIST
308–075
This
manual contains IMPORT
ANT
W
ARNINGS AND INSTRUCTIONS
READ AND RET
AIN FOR REFERENCE
Rev. A
Grounded
Gun
AIR SUPPLY HOSE ADAPTER
Part No. 185–493
For
use with the electrostatic spray gun grounded air
sup
-
ply hoses. Allows conductive air hoses to be coupled
while maintaining the continuity that is necessary
between
the hoses.
NOTE: This adapter has not been tested by the Cana-
dian Standards Association or Factory Mutual.
Installing
this adaptor voids
previous CSA certifi
-
cation
and/or FM approval.
WARNING
Grounding
To
reduce the risk of fire, explosion, or electric shock,
which
may result from electrical discharge, it is essential that all
parts
of the electrostatic system are properly grounded. Stat
-
ic
electricity can be generated by the
flow of fluid through the
pump, hose, gun, and nozzle, but it is dissipated through
proper grounding as described in the spray gun instruction
manual.
The
electrostatic spray gun is grounded through connection
to
a properly grounded air supply
hose. Use only the Graco
Electrically Conductive Air Supply Hose. Connect the air
hose
ground wire to a true earth ground.
If you experience any arcing or feel even a slight shock,
STOP
SPRA
YING IMMEDIA
TELY
. Check for proper ground
-
ing of the entire system. Be sure you have corrected the
problem
before starting to spray again.
Relieving
Fluid & Air Pressures
To
reduce the risk of serious bodily injury
, including splashing
in
the eyes or on the skin, fluid injection
(air
-assisted airless
system),
injury from moving parts or electric shock, follow the
Pressure Relief Procedure as instructed in your electro-
static
spray gun manual.
INSTALLATION
1. Connect the hose adapter between the ends of the
air
hoses as shown in Fig 1.
NOTE: The recommended maximum total length of air
hose is 100 ft (30.5 m). The pressure drop
through longer lengths may lower the voltage
from
the power supply
. A minimum of 2.8 bar (40
psi)
air supply pressure is required to ensure full
voltage
from the power supply
.
2. On
all but the
last air hose (the one closest to the air
supply), trim the grounding wire to approximately 4
inches (102 mm). Secure the grounding wire to the
air hose outer jacket with electrical tape. Keep the
extra
wires and clamp(s).
3. Connect
the grounding clamp of the last air hose to a
true
earth ground.
Fig 1
185–493
GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN 55440–1441
 COPYRIGHT
1990 GRACO INC.

INSTALLATION
Check the Electrical Grounding (See Fig 1)
WARNING
Proper electrical grounding of every part of your
system
i
s
e
ssential
. F
o
r y
ou
r s
afety
, g
roun
d t
h
e s
ystem
as explained in your electrostatic gun manual. Then
check
y
our syste
m a
s e
xplaine
d b
elow.
1.
Make sure the electrostatics are off.
Manual
Spray Gun:
T
urn ES ON–OFF Lever to
OFF
.
Automatic
Spray Gun:
T
urn of
f the turbine air
.
2. Have a qualified electrician check the electrical
grounding
continuity of the spray gun and air hose.
a. With the
electrically conductive
air hose con-
nected and properly grounded, use a
megohmmeter to measure the resistance be-
tween the gun handle and a true earth ground
.
Use
an applied voltage
of 500 minimum to 1000
volts
maximum. See Fig 2.
b. If the resistance is greater than 2 megohms,
check the tightness of the ground connections,
and be sure the air supply hose ground wire is
connected to a true earth ground. If the resis-
tance is still greater than 2 megohms, replace
the
air supply hose.
Using
the Air Hose As A Single Hose Again
If an air hose with a trimmed ground wire is going to be
used
as a single hose again, have a qualified electrician
splice the ground wire and grounding clamp back onto
the
air hose ground wire.
If the original ground wire and clamp are not available,
order grounding clamp 103–538 and ground wire
208–950
and splice them onto the air hose ground wire.
Refer
to Fig 3.
Connect the grounding clamp to a true earth ground.
Check
the electrical grounding as instructed above.
Fig 2
Megohmmeter
Gun Han-
dle
True Earth
Ground Grounded
Air Hose
Grounding Clamp 103–538
Ground Wire 208–950
25
ft. (7.6 m) long, 12 ga. (1.5 mm
)
Fig 3 103–538
208–950
TECHNICAL
DA
TA
Pressure Drop Analysis Graph
This graph shows the pressure drop versus the hose
length
for the Pro Series of
electrostatic spray guns at a
2.8
bar (40 psi) gun inlet pressure.






   





Factory Branches:
Atlanta, Chicago, Dallas, Detroit, Los Angeles, W
est Caldwell (N.J.)
Subsidiary and Affiliate Companies:
Canada; England; Switzerland; France; Germany; Hong Kong; Japan
GRACO INC.
P
.O. BOX 1441
MINNEAPOLIS, MN
55440–1441
PRINTED
IN U.S.A.
308–075
8/90

Other Graco Adapter manuals

Graco 24K461 User manual

Graco

Graco 24K461 User manual

Graco 235486 Operation manual

Graco

Graco 235486 Operation manual

Graco 24W637 User manual

Graco

Graco 24W637 User manual

Graco InvisiPac HM25 Parts list manual

Graco

Graco InvisiPac HM25 Parts list manual

Graco SERIES F User manual

Graco

Graco SERIES F User manual

Popular Adapter manuals by other brands

YOKOGAWA 98031 user manual

YOKOGAWA

YOKOGAWA 98031 user manual

Dixon Bayco DBC62LVPR-300 Maintenance Instruction

Dixon Bayco

Dixon Bayco DBC62LVPR-300 Maintenance Instruction

Cisco AIR-PCI340 Installation and configuration guide

Cisco

Cisco AIR-PCI340 Installation and configuration guide

Allnet ALL168205 Express-setup

Allnet

Allnet ALL168205 Express-setup

Renesas R0E000010ACB00 user manual

Renesas

Renesas R0E000010ACB00 user manual

TerraTec NOXON iRadio Cube manual 

TerraTec

TerraTec NOXON iRadio Cube manual 

Belkin Dual-Band Wireless A+G USB Network Adapter... user manual

Belkin

Belkin Dual-Band Wireless A+G USB Network Adapter... user manual

Sunrich Tech U-2240 user manual

Sunrich Tech

Sunrich Tech U-2240 user manual

ZEPCAM M2 instruction manual

ZEPCAM

ZEPCAM M2 instruction manual

Edimax HP-5102K Specifications

Edimax

Edimax HP-5102K Specifications

Ralink 150N wireless adapter user manual

Ralink

Ralink 150N wireless adapter user manual

Digitus DA-70837 manual

Digitus

Digitus DA-70837 manual

National Instruments SC-205X Series user manual

National Instruments

National Instruments SC-205X Series user manual

Lindy 42799 user manual

Lindy

Lindy 42799 user manual

Fluke ir3000 FC manual

Fluke

Fluke ir3000 FC manual

Aftershokz Loop100 quick start guide

Aftershokz

Aftershokz Loop100 quick start guide

Canon PD-MM100 instructions

Canon

Canon PD-MM100 instructions

ACTiSYS ACT-IR220L user manual

ACTiSYS

ACTiSYS ACT-IR220L user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.