INSTRUCTIONS–P
ARTS LIST
308–075
This
manual contains IMPORT
ANT
W
ARNINGS AND INSTRUCTIONS
READ AND RET
AIN FOR REFERENCE
Rev. A
Grounded
Gun
AIR SUPPLY HOSE ADAPTER
Part No. 185–493
For
use with the electrostatic spray gun grounded air
sup
-
ply hoses. Allows conductive air hoses to be coupled
while maintaining the continuity that is necessary
between
the hoses.
NOTE: This adapter has not been tested by the Cana-
dian Standards Association or Factory Mutual.
Installing
this adaptor voids
previous CSA certifi
-
cation
and/or FM approval.
WARNING
Grounding
To
reduce the risk of fire, explosion, or electric shock,
which
may result from electrical discharge, it is essential that all
parts
of the electrostatic system are properly grounded. Stat
-
ic
electricity can be generated by the
flow of fluid through the
pump, hose, gun, and nozzle, but it is dissipated through
proper grounding as described in the spray gun instruction
manual.
The
electrostatic spray gun is grounded through connection
to
a properly grounded air supply
hose. Use only the Graco
Electrically Conductive Air Supply Hose. Connect the air
hose
ground wire to a true earth ground.
If you experience any arcing or feel even a slight shock,
STOP
SPRA
YING IMMEDIA
TELY
. Check for proper ground
-
ing of the entire system. Be sure you have corrected the
problem
before starting to spray again.
Relieving
Fluid & Air Pressures
To
reduce the risk of serious bodily injury
, including splashing
in
the eyes or on the skin, fluid injection
(air
-assisted airless
system),
injury from moving parts or electric shock, follow the
Pressure Relief Procedure as instructed in your electro-
static
spray gun manual.
INSTALLATION
1. Connect the hose adapter between the ends of the
air
hoses as shown in Fig 1.
NOTE: The recommended maximum total length of air
hose is 100 ft (30.5 m). The pressure drop
through longer lengths may lower the voltage
from
the power supply
. A minimum of 2.8 bar (40
psi)
air supply pressure is required to ensure full
voltage
from the power supply
.
2. On
all but the
last air hose (the one closest to the air
supply), trim the grounding wire to approximately 4
inches (102 mm). Secure the grounding wire to the
air hose outer jacket with electrical tape. Keep the
extra
wires and clamp(s).
3. Connect
the grounding clamp of the last air hose to a
true
earth ground.
Fig 1
185–493
GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN 55440–1441