Green Lighting TRI-SENSOR GL4612LU User manual

GL4612LU
ASSEMBLY & FITTING INSTRUCTIONS
P-LUX3 LED TRI-SENSOR LANTERN
Please read these instructions carefully before attempting to install this lantern.
It is advisable to keep these instructions in a safe place for future reference.
If this lantern is installed by a contractor, the contractor should ensure that the
customer has a copy of these instructions.
SPECIFICATION
Voltage: 230V AC
Lampless: Epistar 8W LED
Weather Resistance: IP44
Electrical Safety: BSEN60598 (Relevant clauses)
Angle of Detection: 120° approx
Max. Detection Range: Up to 6 metres approx; depending
on weather conditions and mounting height
(see INTRODUCTION on Page 2).
Mounting Height: 1.4 to 1.9 metres.
Lux up Operation: Lux up operation in hours of darkness only.
Time On: 60 secs & 60 seconds from last trigger.
TRI-SENSOR™ TECHNOLOGY
Green Lighting Helpline on 01905 610200

SPECIFICATION
The P-lux lantern switches on automatically at dusk. The lantern will stay in a dim down mode,
when the PIR is activated the P-Lux will lux up to full brightness for 60 seconds or 60 seconds
from the last trigger. It will then return to the dim down mode, and switch off automatically at dawn.
approaching. The P-lux3 is fitted with temperature compensation to give a consistent detection
range. (6m) in all weather. For the PIR to work at its best, the PIR should be crossed,
not approached head-on. The examples below illustrate this.
The sensor is controlled by a built-in photocell so that it operates only between dusk and dawn.
Once the sensor has turned on the light, it will stay on for approximately 60 seconds.
NOTE: When the lantern is positioned directly facing a person walking straight towards it,
the detection range can be as little as 1.5 metres.We therefore recommend that the lantern be
positioned to the side of the entrance.
LOCATION
Choose a suitable location for installing the P-LUX lantern, that is, away from trees, hot ventilator
the ground.
6m
120°

INSTALLATION
Ensure electricity is switched off at the mains before installing or maintaining this lantern.
THIS FITTING MUST BE INSTALLED IN ACCORDANCE WITH
CURRENT IEE WIRING REGULATIONS AND BUILDING
REGULATIONS (PART P). FOR YOUR OWN SAFETY, THIS
LANTERN MUST BE EARTHED. UNDER NO CIRCUMSTANCES SHOULD
THIS METAL FITTING BE WIRED TO AN UNEARTHED
CIRCUIT. CONTACT A QUALIFIED ELECTRICIAN TO
INSTALL A SUITABLE EARTH FACILITY.
IF YOU ARE IN ANY DOUBT, CONSULT A QUALIFIED ELECTRICIAN.
Please note: For new installations, check for any electrical cables or pipe work
(gas/water) in the vicinity of the intended mounting point for the product, before
proceeding with the installation.
1. Remove the junction box by removing the dome nuts,
sealing washers and metal washers. Take care of the
weather proof gasket (FIGURE 1).
FIGURE 1
4 X3
1 X2
3 X2
2 X3
5

INSTALLATION - continued
2. Use the junction box as a template
and mark the positions for the two
deep and insert masonry plugs so they
(FIGURE 2).
3. Pierce a hole in the grommet and
push the mains cable through allowing
enough cable for connection to the
terminal block (FIGURE 2).
4. Push the hex screws through the
back of the junction box so they
protrude inside the box (FIGURE 2).
Fix the junction box to the mounting
(FIGURE 2).
6. Connect the mains supply cable to the terminal block using the following
colour code for the wiring (FIGURE 3):
Connect the wire coloured Brown or Red (Live) to the corresponding Brown
wire in the terminal block, or the terminal marked L.
Connect the wire coloured Green/Yellow or Green (Earth) to the corresponding
Green/Yellow wire in the terminal block, or the terminal marked E or .
Connect the wire coloured Blue or Black (Neutral) to the corresponding
Blue wire in the terminal block, or the terminal marked N.
Clip the terminal block on the junction box.
REMEMBER: THIS FITTING MUST BE EARTHED.
P-LUX UNIT
FIGURE 2
FIGURE 3
1
2 X2
L
N

INSTALLATION - continued
7.
ensuring that no wires are trapped and that the gasket makes a tight seal (FIGURE 2).
8.
9. Fit the canopy to the lantern head with the
screws and washers (FIGURE 4).
10. Turn on the mains supply.
Note: Do not use this lantern if it is damaged.
IF IN ANY DOUBT CONSULT A QUALIFIED
ELECTRICIAN.
OPERATING THE LAMP
NOTE: In the wiring examples shown in FIGURES 1 and 4, the switch for the
fused spur doubles as the override switch.
Initial Power Up Cycle
FIGURE 4
Slide the ploycarbonate panel in to place
3 X3
2
On the initial power up, your lantern will go into one complete cycle that is full light for 45 seconds
followed by a slow dim down and it will then switch off (in day time). This power up cycle will
happen regardless the light level of the environment.
After installing your P-Lux 3 Led lantern, simply walk past your lantern and look for the blue
LED (Motion Indicator) on the PIR to flash which means your lantern is in range but the light will not
come on in day light.

TROUBLESHOOTING
f at the mains.
FAULT
Unit will not work at all
Sensing range too short
Lamp on all the time
Lamp false triggers
POSSIBLE CAUSE
• No power
•Area too light
• Re-position lantern
e.g. lighting nearby
• Faulty photocell
low, or angle of approach
into detection bands are
incorrect
• Other lighting interfering
with the sensitivity of the
PIR sensor
• Wrongly wired
• PIR is continuously being
activated
• Faulty electronic unit
• Lantern badly positioned
• High winds
SOLUTION
• Check power and fuse
• Cover the sensor with a black
cloth or black insulation tape
and switch on
• Re-position lantern
if required
• Call the Helpline
• Cover the photo cell with
a dark cloth then test
• Move the unit to a different
height and/or change the
angle of approach
(see INTRODUCTION)
• Move lantern away from
other lighting
• Reposition lantern
•
Call the help line
• Reposition lantern.
•Temporary situation
If annoying, switch lantern off
Please note that this equipment and its components have NO user serviceable parts.
GREENLIGHTING HELPLINE
TEL: 01905 610200
Monday to Friday
www.greenlighting.co.uk
For this reason we reserve the right to make changes to any product at any time, without notice.
Green Lighting Instructions GL4612LU P-Lux3 LED Tri-Sensor Lantern
© Green Lighting
• Switch off for 30 seconds
then restart
Blue LED indicator
doesn’t work
• No power
• Call the helpline
• Check power and fuse
Green Lighting tries to improve its products for the benefit of its customers.
Table of contents