INSTALLATION INSTRUCTIONS:
The G.R.I. 290 Series Door Monitor mounts easily to the wall next to any door which allows access to or from a controlled area. Using
a closed loop magnetic reed switch, the unit will detect and announce an open access door by sounding a loud continuous alarm upon
expiration of the delay time set. A surface mount and a recessed mount model are offered. Both incorporate a built-in shunt
deactivation button to extend door open time without alarm sounding. Although the 290 Series Door Monitor cannot be turned off,
this feature will simply deactivate the alarm function for the maximum time limit chosen. During this time span, the door must be
closed before the alarm sounds. Once the alarm is sounding it can be silenced by closing the door, if the auto reset function has been
chosen. If the auto reset is not chosen, the deactivation button must also be depressed. The sounder cannot be disabled by simply
holding down the deactivation button. If multiple openings lead to the area, the G.R.I. 290 Series alarms can monitor all by installing
closed loop switches wired in series. In this way, any opening will be detected. Auxiliary Normally Open shunt/deactivation buttons
or switches can also be wired to utilize the timed shunt feature. Additional remote sounders may be wired in to extend sounder range.
Please contact your G.R.I. factory representative for additional information or custom software options.
Capable of multiple settings for a delay/shunt time, the 290 series alarms can be configured by simple jumper placement to program the
desired function. Jumper placement and function descriptions are as shown in the following table.
000 = 90 Second Delay/Aux Output Follows Alarm
00X = 60 Second Delay/Aux Output Follows Alarm
0X0 = 30 Second Delay/Aux Output Follows Alarm
X00 = 15 Second Delay/Aux Output Follows Alarm
There is also a jumper setting which allows the auxiliary output to follow the door with auto reset.
To change or reconfigure delay/shunt time, first disconnect all power sources, reposition the jumpers and reapply power. Initially two
beeps should be heard to confirm power up. Within 15 seconds a third beep should be heard to confirm reprogramming is complete.
290-1 290-2
GEORGE RISK INDUSTRIES, INC.
G.R.I. PLAZA
KIMBALL, NE 69145
TOLL-FREE 1-800-445-5218
TOLL-FREE 1-800-523-1227
(308) 235-4645
FAX (308) 235-3561
WEB SITE: www.grisk.com
MADE IN U.S.A.
BA-186 Rev B 3/05/09
DOOR MONITOR
WARRANTY:
One year warranty against workmanship, material and factory defects.