D101 D102 D103
D104 D105 D106
D107 D108 D109
Meaning Meaning Meaning
Compressor operates Air exhaust protection
frequency reducing
Air exhaust protection
frequncy limit
Compressor high pressure protection
unit stop
Cooling overload frequncy
reducing Cooling overload frequncy limit
Air exhaust protection unit stop Over current protection
frequency reducing
Over current protection
frequency limit
Communication malfunction unit stop
(Include indoor unit and driver
Phase current protection
frequncy reducing
Phase current protection
frequncy limit
IPM modular protection
unit stop
Heating A unit anti-high
temperature frequncy reducing
Heating A unit anti-high
temperature frequncy limit
Over current protection
unit stop
Heating B unit anti-high
temperature frequncy reducing
Heating B unit anti-high
temperature frequncy limit
Cooling overload unit stop Heating C unit anti-high
temperature frequncy reducing
Heating C unit anti-high
temperature frequncy limit
Each indoor unit starts heating at same time
anti-high temperature protection unit stop
Heating D unit anti-high
temperature frequncy reducing
Heating D unit anti-high
temperature frequncy limit
Each indoor unit anti-freezing protection
at same time unit stop Defrosting Oil return
Outdoor unit temp. sensor malfunction
or each indoor unit temp. sensor malfunction unit stop
Compressor overload protection
unit stop
Compressor low-pressure protection
unit stop (preserved)
Phase current protection
unit stop
E2 PROM Error
unit stop
DC power supply short circuit
Meaning Meaning Meaning
Outdoor ambient temp. sensor malfunction
Outdoor tube temp. sensor malfunction
Outdoor air exhaust temp. sensor
malfunction
Communication malfunction with
driver (cannot receive correct data from
driver within 10s)
A unit communication malfunction
(cannot receive correct data within
3mins.)
B unit communication malfunction
(cannot receive correct data within
3mins.)
A unit indoor middle temp. sensor
malfunction
B unit indoor middle temp. sensor
malfunction
A unit indoor outlet pipe temp. sensor
malfunction
B unit indoor outlet pipe temp. sensor
malfunction
A unit indoor inlet pipe temp.
sensor malfunction
B unit indoor inlet pipe temp.
sensor malfunction
A unit indoor ambient temp.
sensor malfunction B unit indoor ambient temp.
sensor malfunction
A unit modes conflict B unit modes conflict
A unit anti-freezing protection B unit anti-freezing protection
A unit anti-high temp. protection B unit anti-high temp. protection
Meaning
C unit communication malfunction