GRUP ARGE HT G11 User manual

HT G11 / G12 GSM Terminal
Instruction Manual
GRUP ARGE ENERJİ VE KONTROL
SİSTEMLERİ SAN. ve TİC. LTD. ŞTİ.
İkitelli OSB Mah. YTÜ İkitelli Teknopark Sok.
No: 1/2B1-2B7-2B8-2B9 Başakşehir / İstanbul
Phone: +90 212 438 80 24
Fax: +90 212 438 80 25
Technical Support:
Phone: +90 212 438 61 17
Mobile Phone: +90 549 650 50 53
www.gruparge.com
www.enerjitakibi.com
Version 19-2

HT G11 / G12 GSM Terminal Instruction Manual
2
CONTENTS
PROPER USE and SAFETY REQUIREMENTS ................................................3
1.INTRODUCTION..............................................................................................4
1.1 General Features ..........................................................................................4
1.2 Technical Features.......................................................................................5
1.3 Terminal Connections..................................................................................5
1.4 LED Descriptions.........................................................................................7
2.INSTALLATION INFORMATION..................................................................8
2.1 Installation Information ...............................................................................8
2.2 How to Use Authorized Code?....................................................................9
3.SUPPLY CONNECTIONS..............................................................................10
3.1 AC Supply Connection..............................................................................10
3.2 DC Supply Connection..............................................................................10
4.METER COMMUNICATION CONNECTIONS...........................................11
4.1 Optical Port Connection.............................................................................11
4.2 Makel RS-232 Communication Connection..............................................12
4.3 Makel & Köhler & Viko RS-485 Communication Connection................12
4.4 Elektromed & Luna RS-485 Communication Connection........................13
4.5 Elster RS-485 Communication Connection...............................................13
4.6 EMH RS-485 Communication Connection...............................................14
4.7 Landis RS-485 Communication Connection.............................................15
5. RELAY TERMINAL CONNECTIONS.........................................................16
5.2 Klemsan Relay REMO-Q and RAPIDUS –Terminal Connection...........17
6.SELECTION TABLE ......................................................................................17

HT G11 / G12 GSM Terminal Instruction Manual
3
PROPER USE and SAFETY REQUIREMENTS
Cut all the power when connecting and disconnecting the device
to a panel.
Do not clean the device with a solvent or similar material. Only
use a dry cloth!
Please do not intervene to the device when a technical problem is
encountered and get in contact with a technical service within the
shortest time.
If the warnings are not taken into account, our company or the
authorized dealer shall not be held responsible for the negative
consequences.
Do not dispose in the trash, the device must be delivered to the
collection centers (electronic device recycling centers). It should
be recycled or disposed of without harming human health and
environment.
The installation, assembly, activation and operation of the device
should be done and used by only expert professionals and in
accordance with safety regulations and instructions.
The device operates with current transformers. Do not strictly
leave current transformer tips unattached. Dangerous high voltage
can occur.

HT G11 / G12 GSM Terminal Instruction Manual
4
1.INTRODUCTION
1.1 General Features
HT G11/G12 GSM communication terminal provide remote monitoring
for devices such as electronic electric meters, compensation relays and energy
analyzers supporting Modbus protocol. It provides communication with the
devices that has Modbus protocol via RS-485 port, with electric meters via
optical communication ports, RS-232 (3-wire) or RS-485 (2-wire).
In order for the communication terminals to establish an internet
connection, a SIM card with a capacity of at least 100 MB with M2M property
should be inserted into the device. If a PIN code is defined on the SIM card, the
PIN code must be canceled by inserting the SIM card into a mobile phone.
HT G11/G12 GSM communication terminals query the data of the
connected devices and send it to Grup Arge servers via GSM network (mobile
phone network). You can access the data of all your devices by visiting our
website located at www.enerjitakibi.com with your provided user account.
The main reports on the web interface are as follows:
• Active consumption reports
• Reactive ratio reports
• Instant electrical parameters such as current and voltage
• Step values (only for compensation relays)
Moreover, in the case of specific alerts, the system notifies the situation to
related persons by e-mail and SMS alerts.

HT G11 / G12 GSM Terminal Instruction Manual
5
1.2 Technical Features
Microprocessor based.
HT G11 GSM Terminal operates with 85-265 V AC supply.
HT G12 GSM Terminal operates with 10-30 V DC supply.
It has RS-485, RS-232 and optical port communication channels.
It must be able to communicate with all meters supporting TS EN 62056-
21 protocol.
It can read 32 meters or 247 Modbus devices via RS-485.
It has LEDs that indicate RS-485/Optical/RS-232 (Communication),
GSM connection and internet status.
The data transmission period can be set between 1-240 minutes.
It has a system architecture which does not require static IP.
For the locations of weak GSM network signal, it has wired GSM antenna
support.
It is compatible with M2M SIM Cards of all GSM operators.
The operating ambient temperature of the device is between -10 °C and
+55 °C.
The power consumption is less than 1 VA.
It has IP40 protection class.
The dimensions of the device (width-length-depth) are 35×110×80mm.
1.3 Terminal Connections
Chart 1.1
SIM Card
SIM Card Slot
Antenna
GSM Antenna Connector (SMA)
AC 85/265 V
DC 10/30 V
AC/DC Power Supply Input
VDD
Optical Reader Supply (6.2 V DC)
RS-232
TX
Optical / RS-232 Data Transmit
RX
Optical / RS-232 Data Receive
GND
Optical / RS-232 Ground
RS-485
A
RS-485 Data +
B
RS-485 Data -

HT G11 / G12 GSM Terminal Instruction Manual
6
WARNING! VDD, TX, RX, GND, A, B terminals should not be connected to the
mains.
Figure 1.1

HT G11 / G12 GSM Terminal Instruction Manual
7
1.4 LED Descriptions
1. 4 level LED: It indicates GSM signal quality. If all 4 are on, it has the
best signal. If a single LED or none is on, it is recommended to amplify
the signal with a wired antenna (ANT 03 or ANT 07).
2. When the LED is steady, it indicates the server connection has been
established. When it is flashing, it is attempting to establish a connection.
3. No server connection is established.
4. The SIM card is not inserted, or the PIN code is not cancelled.
5. It indicates a communication problem in RS-485 line.
6. A query is sent from the terminal via RS-485 port.
7. A response comes to the terminal from RS-485 port.
8. It indicates a communication problem in Optical/RS-232 line.
9. A query is sent from the terminal via optical/RS-232 channel.
10. A response comes to the terminal from optical/RS-232 channel.
11. Power LED: It indicates whether there is power or not in the device.

HT G11 / G12 GSM Terminal Instruction Manual
8
2. INSTALLATION INFORMATION
2.1 Installation Information
1. Secure the device to a suitable place in the panel. (Suitable for rail
mounting)
2. Make a supply connection to terminal named “AC 85/265 V” or “DC
10/30 V”. Make sure that there is no power in the cables in the
meanwhile.
WARNING! If AC voltage is applied to the devices with DC supply, the
device is out of warranty.
Connection between the device to be communicated:
a. Electric Meter / Optical Port: See. Figure 3.1
b. Electric Meter / RS-232: See. Figure 3.3
c. Electric Meter / RS-485: See. Figure 3.4; 3.5; 3.6; 3.7; 3.8; 3.9
d. Modbus Device (Relay, analyzer etc.) / RS-485: See. Figure 4.1; 4.2
3. Cancel the PIN code of the SIM card and insert into the SIM card slot as
shown on the device.
4. Operate the device by energizing after checking all the connections for the
last time.
5. After a while, by entering SmartPower Energy Monitoring System, you
can check whether your device is sending data or not. If you have no
internet access in the field, you can get help from our technical support
line.
NOTE
1. If the GSM signal power is insufficient, disassemble the whip antenna on
the device and assemble a wired antenna instead.
2. If more than one meter is to be connected via RS-485, the technical
support line must be called, and serial numbers of the meters must be
defined to the system.

HT G11 / G12 GSM Terminal Instruction Manual
9
3. Modbus devices to be read via RS-485 must be defined to the system. The
Modbus addresses of all the devices on the same line must be different.
For this purpose, you may need to enter the menu of related device and
change the Modbus address.
2.2 How to Use Authorized Code?
1. Login to SmartPower Energy Monitoring System and go to “Modem”
page.
2. Click “Add Modem Authorization” button and enter the information of
“Authorization Code” paper which comes out of the product box.
3. If the information is entered correctly, the device will be automatically
transferred to your account.
4. Dispose of the authorization code paper after the process is done.
Figure 2.1

HT G11 / G12 GSM Terminal Instruction Manual
10
3.SUPPLY CONNECTIONS
3.1 AC Supply Connection
Figure 3.1
3.2 DC Supply Connection
Figure 3.2

HT G11 / G12 GSM Terminal Instruction Manual
11
4.METER COMMUNICATION CONNECTIONS
4.1 Optical Port Connection
Figure 4.1
NOTE: When placing the optical reader on the meter,
make sure the arrow mark on the label points to upward
direction.
Figure 4.2
Table 4.1
Cable Color
Brown
Green
Yellow
White
Terminal
VDD
TX
RX
GND

HT G11 / G12 GSM Terminal Instruction Manual
12
4.2 Makel RS-232 Communication Connection
Figure 4.3
4.3 Makel & Köhler & Viko RS-485 Communication Connection
Figure 4.4

HT G11 / G12 GSM Terminal Instruction Manual
13
4.4 Elektromed & Luna RS-485 Communication Connection
4.5 Elster RS-485 Communication Connection
There are two RS-485 terminals in some models of Elster meters.
Figure 4.5
Figure 4.6

HT G11 / G12 GSM Terminal Instruction Manual
14
4.6 EMH RS-485 Communication Connection
Figure 4.8
Figure 4.7

HT G11 / G12 GSM Terminal Instruction Manual
15
4.7 Landis RS-485 Communication Connection
NOTE: In order to read Landis Meters via RS-485, the technical support
line must be called, and serial number of the meter must be introduced on
the system.
Figure 4.9

HT G11 / G12 GSM Terminal Instruction Manual
16
5. RELAY TERMINAL CONNECTIONS
If compensation relay or analyzer to be connected to communication
terminals are named as A and B, A must be connected to A; and B must be
connected to B. The connection of the different named devices is showed below.
NOTE:
The Modbus addresses and types of the devices that connected to modem
must be defined by entering the setup page of the relevant modem via web
interface.
Modbus addresses of Grup Arge products without screen are found by
adding 100 to the last 2 digits of serial number of the device.
5.1All Relays Using A-B Naming Terminal Connections
Figure 5.1

HT G11 / G12 GSM Terminal Instruction Manual
17
5.2 Klemsan Relay REMO-Q and RAPIDUS –Terminal
Connection
6.SELECTION TABLE
Table 6.1
Figure 5.2
This manual suits for next models
1
Table of contents
Other GRUP ARGE Touch Terminal manuals