PA mounting
PA mounting
To remove PCB, push
clip forward
To remove Battery,
lift up
Fitted with
1 x ICR123
Rechargeable
750mA Battery
+ -
Power in 5V to 13V DC
Replace back tamper
plate if removed for
drilling holes through
Drill through appropriate pilot
holesinrearenclosureandmount
to wall
Mount Holes
mount with
2 x 1 inch No.8
security screws
2. Flat mounting
1. Corner mounting 3. Edge mounting
Base mounting diagrams.
Enrolling on a GSDi intrusion system
1.
2.
3.
4.
5.
6.
7.
8.
9.
On the system start enrolling: see GSDi installation manual for details.
Remove the front cover from GSDi-RF-RPT.
Remove battery Tab
Connect power (5 - 13V) to the Terminals, ie.:i70 Panel Aux Power
Press and hold the front tamper.
If removing PCB from the base, ensure that the back tamper is closed before
closing front tamper.
Wait about 5 seconds.
When the LED on the front lights, release the tamper switch.
- The sensor flashes the LED to indicate it is searching for the system.
- When it finds the system the Panel will display a message.
At the Panel click Finish or Test Device
- Test Device; Signal Range < Next > Status (Open /Tamper) < Next > Device
Name < > Area < Next > Device Setting < Next > Finish
Replace front cover on GSDi-RF-RPT and secure it with the fixing screw.
Note: Any device using the Repeater will show Signal Boostings.
N.B. USE RECHARGABLE BATTERY ONLY.
RPT opening
2 Operation Instructions 3
Installation Diagrams