GSM Activate IR BEAM User manual

PAGE1
MODEL P I R - I R B E A M
2G & 3G PIR / IR BEAM
Detector

Page 2
Our 2G/3G PIR or Beam Detector is a standalone alarm system suitable for outdoors or
indoor usage.
It will alert you using GSM technology by sending you a text message and/or phone call
When the sensor has been triggered to your mobile or landline phones.
The unit is also enclosed in a IP65 rated box which means it is perfectly weathered for
outside installation and has passed testing in high temperature and below
freezing conditions.
GSM Frequency: Quad band fre 850/900/1800/1900/ 3G Model 2100 Mhz.
Power Supply Voltage: 9 - 24 volts DC - 1 Amp Max
Current used in standby mode: 60mA Max
IP 65 Enclosure rating for outside installation
8 Amp Relay Output
Micro 2G or 3G Simcard
No land line required
Dimensions - L150 x W90 x H45mm
Dimensions PCB Only - L125 x W67mm
Sim Active Function
Operating Temperature: -10...+40°C
Programmed by Text / SMS Message
Text to test signal strength
2 Inputs

To help make sure that you place the unit in a suitable position you can text the unit to see
how much signal strength the dialler is receiving by texting the command
The dialler will perform a test on the signal strength.
You will receive a text telling you a signal strength score between 0 up to 30 we strongly
recommend that you place the unit where you can receive a signal strength score of at least
10. You will find that with a score of less than 10 the unit will be unreliable.
Page 3
Slide the simcard into the holder making sure that the clipped corner of the simcard
lines up with the clipped corner of the simcard holder as picture above.

After inserting your simcard into the Auto-Dialer turn the unit on and wait until you see the
LED is on. This will indicate that you have a mobile signal and the unit is
ready for use.
You will now need to send a text with the contact number
Note - To avoid confusion we have colour coded the hash (#) and the equals (=) symbols.
Example: (hash) (1 or 2 or 3) (equals) (phone number) (hash)
then send this as a text to the simcard number of your unit
then send this as a text to the simcard number of your unit
then send this as a text to the simcard number of your unit
If you wish to cancel a number follow this example
Example: (hash) (1 or 2 or 3) (equals) (DELETE) (hash)
Then send this as a text to the simcard number of your unit
Please send one message at a time and wait for the Auto Dialler to send you back the text
Acknowledgement ‘NUMBER STORED’ before you try to add another number.
Below is a notepad to help you remember the numbers that you have saved to your
unit in the event you need to modify or delete in the future.
#1=________________________ #
#2= ________________________#
#3=________________________ #
Page 4

The auto dialler can be programmed to send you a telephone call after each text alarm
has been sent.
You will receive approximately three ring tones. The unit will then hang up automatically.
This is to prevent call charges being incurred.
To set call alerts to ON please send the text message
The unit will reply back “call on”
To disarm call alerts please send the text message.
If the call function has been set to you will receive a text message and shortly after a
phone call.
Page 5
You can now change the alarm message for inputs 1 & 2 to your own choosing.
To change the message send the text command as follows.
#MESS1= YOUR MESSAGE # (Input 1 Detected) Input 1
#MESS2= YOUR MESSAGE # (Alarm triggered) Input 2
This will change the message to “YOUR MESSAGE”
Default message

Page 6
ref page 3
The 3G Auto Dialler has a 8 amp relay output which can be used to switch on external
electric devices such as lighting, sirens etc.
By texting the unit you can turn the relay ON or OFF. Below are examples on how to do
this.
- This will turn on relay output
-This will turn off relay output
After each operation the unit will reply with a status report
ref page 3
The relay can also be setup to pulse for 20 seconds when the inputs have been triggered.
To activate this mode you need to set DIPSWITCH 2 ON position. Ref page 3
This can be used to reset auxiliary equipment.
The 2G/3G PIR and IR Beam Detector has two independent input’s
Input 1 = Detect and Auto Reset & Input 2 = Alarm Detect
—-—––––––––––––––-—–-—–––––-—–––-—–-—–––-—–-
Input 1: The unit Is always armed and will trigger when the movement is detected, it will
automatically reset after 20 Seconds when no movement is detected. you will receive a text
message “INPUT DETECTED”
Input 2: If you decide to use Input 2 you will need to set the alarm to ON by sending a text
message.
#ALARM=ON#this will activate the alarm.
When movement is detected you will receive a text message “ALARM TRIGGERED”.
It is important to remember That when the alarm has been triggered you will need to reset the
alarm by sending another text message #ALARM=ON#
To cancel the alarm send a text message #ALARM=OFF#
When the inputs are triggered the GREEN READY LED will flash 6 times to indicate that a trigger
has been received and it will send a text / call message to the saved user numbers
HOW TO USE THE 2G/3G PIR & IR BEAM
Note:

Page 7
Typical Application of Product
Security alarm system applications
Supervision and monitoring alarm systems
Automatic monitoring system
Vending machines security protection
Buildings and real estate
Weather stations
River monitoring and flood control
Fridges/Fish Tanks
Farming equipment and security
Dipswitch settings
Dipswitch 1 = ON = 3G Selected
OFF = 2G Selected
Dipswitch 2 = ON= Relay Mode on
OFF=Relay Mode off
CALL+TEXT
CALL ONLY
INPUT 2 ONLY
To reset the unit back to factory settings you will need to send a text message #RESET#
Warning this will reset all of your parameters, only send a reset command when necessary.
The green ready led will flash 8x
RESET

INPUTS
1 : A u t o D e t e c t
2 : A l a r m D e t e c t
3 : n o t u s e d
Relay Output
The relay has a Common, Normally Open and Normally Closed volt free contacts which
are capable of 8 Amp loads. This is suitable for turning ON or OFF electrical equipment.
Alternatively it can be used for resetting your alarm system.
The relay can be manually activated by text message commands or it can be set to pulse
for 20 seconds when an input has been activated - refer to page 6
PAGE 8
Please make sure you supply a 9 - 24 volts DC from the battery terminals via a 2
amp fuse (for alarm panel installations)
For more technical support please browse the FAQ’s on our website
Alternatively email our technical support team at and we
will do our best to reply within 24 hours Monday - Friday.
02/04/2018
Note: Input 3 Not used
6
This manual suits for next models
1
Table of contents
Other GSM Activate Security Sensor manuals
Popular Security Sensor manuals by other brands

Honeywell
Honeywell Miller TurboLite Series User instruction manual

Visonic
Visonic CLIP SMA installation instructions

GROTHE
GROTHE CALIMA 200 Series Installation and operating instructions

Interlogix
Interlogix EV1116 Series Installation sheet

resideo
resideo Honeywell Home PROA7 Series user guide

Profort
Profort climaSpot manual