MODEL NUMBER 4G-SWV-V8

Page 2
Product Information
Our 2G/3G/4G GSM Multi switch is designed to attach to your electronic devices enabling you to activate
them using your mobile phone from anywhere in the world.
This can prove to be very useful in a variety of situations. Just simply dial the unit which comes with a free
simcard and it will turn the device on or off or you can text it how long you would like the device on for
ranging from 1 - 999 seconds or minutes. Once you have sent a command the device will send an
acknowledgement back by text message so you know it has taken the command.
Our 2G/3G/4G Multi Switch is set apart from other models on the market by being on the quad band
frequency, meaning it can be used worldwide and we frequently ship models all over Europe, USA and
Australia with excellent feedback. The unit is also enclosed in an IP65 rated enclosure meaning it is
perfectly weathered for outside installation and has passed testing in high temperatures and below freezing
conditions.
Specification
● The GSM Switch has been designed to operate electronic equipment by using your mobile phone or
land line as the controller.
● It is very easy to install and operates with no complicated coding required. Just plug in and go!
● GSM Frequency: Quad band freq 850/900/1800/1900 / (3G) 2100 / (4G) 2600 Mhz
● Micro 2G or 3G simcard
● Simply dial the simcard number to operate the relay
● If you call the unit it will reject call to avoid call charges.
● You will receive a text acknowledgement to say relay ON or OFF
● INPUT - 240vac (12/24vdc & 115VAC available)
● 2 x Output Relay - 10 AMP N/O or N/C Volt Free
● Phone list for added security of up to 60 stored numbers
● You can set the timer for 1 - 999 minutes
● Pulse Function for both relays
● Sim Active Function
● Dimensions - L150 x W90 x H45mm
● Dimensions PCB Only - L125 x W67mm
● Operating Temperature: -10…+40ºC
● Relay State Report for both relays
● Text for Signal Strength

INSTRUCTIONS
IMPORTANT- PLEASE READ
PLEASE MAKE SURE YOU DISCONNECT THE POWER WHEN YOU FIT THE SIMCARD
AND YOU PLACE THE SIMCARD WITH THE CLIPPED CORNER AS SHOWN IN THE
PICTURE ABOVE.
Powering GSM Multi Switch
Connect 240 volts to the input connector as per figure 1. Once power has been applied the
blue network LED light will flash once every second. Once a signal has been found the green
LED will come on and stay on indicating the unit is now ready for use.
Signal Strength
To check the strength of the signal received please send a text message
#SIGNAL#
The unit will reply back with a score from 1 - 30. The unit must have a score of at least 10 to
work effectively. Anything less than 10 will make the unit unreliable.
2G 3G 4G
The 2G/3G/4G Multi Switch can work on both the 2G , 3G and 4G networks. You can choose
which network the unit will use at the start up via different combinations on the dipswitch
Dipswitch 1 ON The unit will boot up in 3G or 4G, whichever is strongest for the area
Dipswitch 1 OFF The unit will boot up in 2G only
With Dipswitch 1 on the unit will do search for the strongest out of 3G or 4G. A slow flashing
blue light indicates it is on 3G and a fast flashing blue light indicates it is on 4G. We do not
lock to 3G or 4G as the signal strengths vary massively from location to location.
We strongly recommend checking the signal strength on both dipswitch settings and using which
has the highest signal strength score. The signal strength should be at least a score of 10 for
reliability.
Page 3

Page 4
How to program the Multi Function Switch
Once the unit has a green light it is ready to be used. The unit has a caller id function so
only authorised numbers you store can activate the unit. If caller ID is left OFF anyone
phoning the units number can operate the relays.
To turn caller ID on send a text message #ID=ON#
To turn caller ID off send a text message #ID=OFF#
PLEASE NOTE
If you do not require authorised users please skip to the next page
How to Use the Multi Function Switch
To program a number to the caller ID (whl) list you will need to send a text message code:
#WHL#NUMBER#
To delete the number send a text message code:
#DEL#NUMBER#
Example #WHL#07123456789# Stores your mobile number (Maximum 60 users)
Example #DEL#07123456789# Deletes the mobile number.
If the code is accepted the unit will reply “WHL number stored” or “WHL number deleted”
Once the numbers have been programmed please set dispwitch 2 to ON position
PLEASE NOTE
You can only send one number at a time. Please send the message and wait for the
2G/3G/4G Multi Switch to send you back a text acknowledgement ‘STORED’ before you
try to add any further contact numbers.
Furthermore, please ensure that you have credit on your simcard to receive the text
acknowledgment. It may take some time to receive text acknowledgements depending
upon how busy your telephone network is at the time.
Reset Function
For a quick reset and to clear all numbers there is a built in reset function that is triggered
via sending an sms/text message.
#RESET# The unit will then remove all WHL numbers stored.
Please only do this if you really have to as it will clear all your programmed contact
numbers.

How to use the Multi Function Switch
Call Mode: Relay 1 only
Using your mobile phone dial the simcard number. You will hear 1 ring tone. The unit will
automatically hang up. This will prevent any call charges. Only relay 1 can be used for
calling.
The relay will then turn ON and remain on.
You will receive a relay state report REL1 ON REL2 OFF
To turn the relay OFF just ring the simcard number again.
You will receive a relay state report REL1 OFF REL2 OFF
#STATE=OFF# Turns OFF the relay state report
#STATE=ON# Turns ON the relay state report
The default setting configuration is set to relay state report on
Text Mode: Relay 1 & 2
By texting the unit you can turn relay 1 & 2 on or off individually. Below are examples on
how to do this.
#REL1=ON# This will turn on relay 1
#REL1=OFF# This will turn off relay 1
#REL2=ON# This will turn on relay 2
#REL2=OFF# This will turn off relay 2
It is possible to pulse relay 1 & 2 for a period of 10 seconds you will need to send a text as
follows.
#PULSE=1# This will turn on relay 1 for 10 seconds only.
#PULSE=2# This will turn on relay 2 for 10 seconds only.
Timer Mode: Relay 2 only
It is possible to turn the relay 2 ON for a period of time 1 minute to a maximum 999
Minutes. Send the following command followed by the number of minutes you require the
hash
#MIN=
Example #MIN=001# This will turn on the relay for 1 minute.
Example #MIN=060# This will turn on the relay for 60 minutes.
Example #MIN=120# This will turn on the relay for 120 minutes.
The maximum number of minutes is 999.
You will receive a text acknowledgment “TIMER SET”
The timer will stay on for the preset time and then turn itself off. If you wish to cancel the
timer before the preset time has expired you can do this by texting #MIN=000# this will
cancel the time.
Page 5

Status Report
It is possible to obtain a relay status report at any time. This will give you the position of the
relays.
#REL=STATE# To get relay status report
Please Note
The unit has a “sim active” function which monitors the activity on the simcard. If it has
been inactive for 6 weeks, it will send an automatic text to a pre-recorded number. This will
then eliminate the problem of your sim getting shut down if they are unused for 3 months.
New SIM cards will need registering before they can be used. Full details of how this is
done can normally be found in the SIM card pack. It will normally require that the SIM card
is inserted into a mobile phone, a number dialled and instructions followed. While the SIM
is in the mobile phone it would be a good time to disable any PIN codes, call diverts, ring
back and disable features such as voicemail and text alerts. Details of how to do this can
be found on the SIM card provider’s web site or by calling their customer services. Please
use one of the following SIM card providers - Vodafone, TMobile, O2 or Orange.
Note Currently not suitable with the network provider “three”
Quick Programming Commands
Relay Memory
In the event of power loss the switch can remember the relay positions for when the power
has been restored, please send the text as follows
#RELMEM=ON# The unit will remember relay status in event of power failure
#RELMEM=OFF# The unit will not remember relay status and power on with both relays
set to off
The default setting is Relay Memory OFF
Relay State report is the status of BOTH relays
REL 1 OFF = REL 2 OFF
REL 1 ON = REL 2 OFF
REL 1 OFF = REL 2 ON
REL 1 ON = REL 2 ON
Page 6

For more technical support please browse the FAQ’s on our website www.gsm-activate.co.uk
Alternatively email our technical support team at [email protected] and we will
do our best to reply within 24 hours Monday - Friday.
Page 704/11/2020 - AD
Table of contents
Other GSM Activate Switch manuals
Popular Switch manuals by other brands

Brocade Communications Systems
Brocade Communications Systems A7533A - Brocade 4Gb SAN Switch Base Command reference

ANTAIRA
ANTAIRA LMP-0602-24 Series user manual

BLAUBERG
BLAUBERG SGR-3/1 Operation manual

Enabling Devices
Enabling Devices 7459 user guide

HP
HP 5920 installation guide

SMC Networks
SMC Networks ZSE1 Series user manual