GW Instek APS-7000 Series User manual

Programmable AC Power Source
APS-7000 Series
USER MANUAL
ISO-9001 CERTIFIED MANUFACTURER

This manual contains proprietary information, which is protected by
copyright. All rights are reserved. No part of this manual may be
photocopied, reproduced or translated to another language without
prior written consent of Good Will company.
The information in this manual was correct at the time of printing.
However, Good Will continues to improve products and reserves the
rights to change specification, equipment, and maintenance
procedures at any time without notice.
Good Will Instrument Co., Ltd.
No. 7-1, Jhongsing Rd., Tucheng Dist., New Taipei City 236, Taiwan.

Table of Contents
3
Table of Contents
SAFETY INSTRUCTIONS ...................................................4
GETTING STARTED.......................................................... 8
APS-7000 Series Overview......................9
Appearance .......................................... 14
OPERATION .................................................................. 26
Set Up.................................................. 28
Basic Operation ................................... 60
Advanced Settings ............................... 82
Miscellaneous...................................... 88
Trigger ................................................. 95
Preset Settings................................... 100
Arbitrary Waveform Function ............. 104
Test Mode Function ........................... 112
REAR PANEL SIGNAL OUTPUTS....................................149
COMMUNICATION INTERFACE ....................................153
Interface Configuration ...................... 154
FAQ..............................................................................175
APPENDIX ....................................................................177
Firmware Update ............................... 177
APS-7000 Default Settings ................. 179
APS-7000 Specifications..................... 181
APS-7000 Dimensions ........................ 187
Declaration of Conformity.................. 191
INDEX ..........................................................................192

APS-7000 Series User Manual
4
SAFETY INSTRUCTIONS
This chapter contains important safety
instructions that you must follow during
operation and storage. Read the following before
any operation to ensure your safety and to keep
the instrument in the best possible condition.
Safety Symbols
These safety symbols may appear in this manual or on the
instrument.
WARNING
Warning: Identifies conditions or practices that
could result in injury or loss of life.
CAUTION
Caution: Identifies conditions or practices that
could result in damage to the APS-7000 or to other
properties.
DANGER High Voltage
Attention Refer to the Manual
Protective Conductor Terminal
Earth (ground) Terminal

SAFETY INSTRUCTIONS
5
Do not dispose electronic equipment as unsorted
municipal waste. Please use a separate collection
facility or contact the supplier from which this
instrument was purchased.
Safety Guidelines
General
Guideline
CAUTION
Do not place any heavy object on the APS-7000.
Avoid severe impact or rough handling that
leads to damaging the APS-7000.
Do not discharge static electricity to the APS-
7000.
Use only mating connectors, not bare wires, for
the terminals.
Do not block the cooling fan opening.
Do not disassemble the APS-7000 unless you are
qualified.
(Measurement categories) EN 61010-1:2010 specifies the
measurement categories and their requirements as follows. The
APS-7000 doesn’t fall under category II, III or IV.
Measurement category IV is for measurement performed at the
source of low-voltage installation.
Measurement category III is for measurement performed in the
building installation.
Measurement category II is for measurement performed on the
circuits directly connected to the low voltage installation.
0 is for measurements performed on circuits not directly
connected to Mains.
Power Supply
WARNING
AC Input voltage range:
115/230 Vac ± 15% (APS-7050, APS-7100)
230 Vac ± 15% (APS-7200, APS-7300)
Frequency: 50/60Hz
To avoid electrical shock connect the protective
grounding conductor of the AC power cord to
an earth ground.

APS-7000 Series User Manual
6
Cleaning the APS-
7000
Disconnect the power cord before cleaning.
Use a soft cloth dampened in a solution of mild
detergent and water. Do not spray any liquid.
Do not use chemicals containing harsh material
such as benzene, toluene, xylene, and acetone.
Operation
Environment
Location: Indoor, no direct sunlight, dust free,
almost non-conductive pollution (Note below)
Relative Humidity: 20%~ 80%, no condensation
Altitude: < 2000m
Temperature: 0°C to 40°C
(Pollution Degree) EN 61010-1:2010 specifies the pollution degrees
and their requirements as follows. The APS-7000 falls under degree
2.
Pollution refers to “addition of foreign matter, solid, liquid, or
gaseous (ionized gases), that may produce a reduction of dielectric
strength or surface resistivity”.
Pollution degree 1: No pollution or only dry, non-conductive
pollution occurs. The pollution has no influence.
Pollution degree 2: Normally only non-conductive pollution
occurs. Occasionally, however, a temporary conductivity caused
by condensation must be expected.
Pollution degree 3: Conductive pollution occurs, or dry, non-
conductive pollution occurs which becomes conductive due to
condensation which is expected. In such conditions, equipment
is normally protected against exposure to direct sunlight,
precipitation, and full wind pressure, but neither temperature
nor humidity is controlled.
Storage
environment
Location: Indoor
Temperature: -10°C to 70°C
Relative Humidity: ≤80%, no condensation
Disposal
Do not dispose this instrument as unsorted
municipal waste. Please use a separate collection
facility or contact the supplier from which this
instrument was purchased. Please make sure
discarded electrical waste is properly recycled to
reduce environmental impact.

SAFETY INSTRUCTIONS
7
Power cord for the United Kingdom
When using the instrument in the United Kingdom, make sure the
power cord meets the following safety instructions.
NOTE: This lead/appliance must only be wired by competent persons
WARNING: THIS APPLIANCE MUST BE EARTHED
IMPORTANT: The wires in this lead are coloured in accordance with the
following code:
Green/ Yellow:
Earth
Blue:
Neutral
Brown:
Live (Phase)
As the colours of the wires in main leads may not correspond with
the coloured marking identified in your plug/appliance, proceed
as follows:
The wire which is coloured Green & Yellow must be connected to
the Earth terminal marked with either the letter E, the earth symbol
or coloured Green/Green & Yellow.
The wire which is coloured Blue must be connected to the terminal
which is marked with the letter N or coloured Blue or Black.
The wire which is coloured Brown must be connected to the
terminal marked with the letter L or P or coloured Brown or Red.
If in doubt, consult the instructions provided with the equipment
or contact the supplier.
This cable/appliance should be protected by a suitably rated and
approved HBC mains fuse: refer to the rating information on the
equipment and/or user instructions for details. As a guide, a cable
of 0.75mm2should be protected by a 3A or 5A fuse. Larger
conductors would normally require 13A types, depending on the
connection method used.
Any exposed wiring from a cable, plug or connection that is
engaged in a live socket is extremely hazardous. If a cable or plug is
deemed hazardous, turn off the mains power and remove the cable,
any fuses and fuse assemblies. All hazardous wiring must be
immediately destroyed and replaced in accordance to the above
standard.

APS-7000 Series User Manual
8
GETTING STARTED
This chapter describes the power source in a
nutshell, including its main features and front /
rear panel introduction.
APS-7000 Series Overview ......................................... 9
Series lineup ........................................................................................ 9
Operating Area ................................................................................... 9
Main Features ...................................................................................11
Accessories ........................................................................................12
Appearance.............................................................. 14
Front Panel........................................................................................14
Rear Panel..........................................................................................19
Status Bar Icons................................................................................24

GETTING STARTED
9
APS-7000 Series Overview
Series lineup
The APS-7000 series consists of 4 models, the APS-7050, APS-7100,
APS-7200 and APS-7300, differing only in capacity. Note that
throughout the user manual, the term “APS-7000” refers to any of
the models, unless stated otherwise.
Model name
Max. Output Current
Power Rating
Output Voltage
APS-7050
4.2A/2.1A
500VA
0~310.0 Vrms
APS-7100
8.4A/4.2A
1000VA
0~310.0 Vrms
APS-7200
16.8A/8.4A
2000VA
0~310.0 Vrms
APS-7300
25.2A/16.8A
3000VA
0~310.0 Vrms
Operating Area
Voltage (V)
Current (A)
0
1
2
0
3
4
5
100 200 300 400 500 600
120 155 240 310 480 600
4.2
3.23
2.1
1.62
1.05
0.83
APS-7050 Output Operating Area
155V Range 310V Range 600V Range
(APS-003 Option)

APS-7000 Series User Manual
10
Voltage (V)
Current (A)
0
2
4
0
6
8
10
100 200 300 400 500 600
120 155 240 310 480 600
8.4
6.45
4.2
3.23
2.1
1.67
155V Range 310V Range 600V Range
APS-7100 Output Operating Area
(APS-003 Option )
Voltage (V)
Current (A)
0
5
10
0
15
20
100 200 300 400 500 600
120 155 240 310 480 600
16.8
12.9
8.4
6.45
4.2
3.33
155V Range 310V Range 600V Range
APS-7200 Output Operating Area
(APS-003 Option )

GETTING STARTED
11
Voltage (V)
Current (A)
0
5
10
0
15
20
25
100 200 300 400 500 600
120 155 240 310 480 600
25.2
19.4
12.6
9.7
6.3
5.0
155V Range 310V Range 600V Range
APS-7300 Output Operating Area
(APS-003 Option )
Main Features
Performance
Low output ripple and noise
Excellent and feature-rich measurement
capacity
Standard maximum output voltage is 310Vrms
Maximum output voltage and frequency of
600Vrms(APS-003 Option)/1000Hz(APS-004
Option)

APS-7000 Series User Manual
12
Features
OCP, OPP and OTP protection
Variable voltage, frequency and current limiter
Sequence and simulation function
Large 4.3 inch TFT panel
Globally adjustable power inlet not restricted by
the power supply environment
USB interface is equipped as standard with the
ability to save and recall setup files.
Only 88mm (2U) case height (APS-7050 and
APS-7100 models only).
Interface
Standard:
Ethernet port
USB host
USB CDC (APS-7200 and APS-7300 models
only)
Optional:
GPIB
RS-232 / USB CDC (APS-7050 and APS-7100
models only)
RS-232 (APS-7200 and APS-7300 models only)
Accessories
Standard
Accessories
Part number
Description
CD ROM
User manual,
programming manual
82GW1SAFE0M*1
Safety guide
Region dependent
Type I Power cord
(APS-7050)
Region dependent
Type II Power cord
(APS-7100)

GETTING STARTED
13
Region dependent
Type III Power cord
(APS-7200, APS-7300)
62PS-7K0SC701 x1
5302-01613001 x1
Mains terminal cover set
(APS-7050)
62PS-7K0SC401 x1
5302-01613001 x2
Mains terminal cover set
(APS-7100)
GTL-123
Test leads: 1x red, 1x black
Optional
Capacity
Part number
Description
APS-003
Output Voltage Capacity:
0 ~ 600Vrms
APS-004
Output Frequency Capacity:
45 ~ 1000Hz
Optional
Accessories
Part number
Description
GRA-423
APS-7050 and APS-7100
rack mount kit
GRA-429
APS-7200 rack mount kit
GRA-430
APS-7300 rack mount kit
APS-001
GPIB interface card
APS-002
RS-232 / USB CDC
interface card (APS-7050
and APS-7100 only)
APS-007
RS-232 interface card (APS-
7200 and APS-7300 only)
GPW-004
Power Cord 8mm2/3C, 3m
Max Length, 105°C,
RNYBS8-6*3P, RNYB8-
8*3P
Download
Name
Description
gw_aps.inf
USB driver

APS-7000 Series User Manual
14
Appearance
Front Panel
APS-7050, APS-7100
APS-7050 AC Power Source Display
Programmable
F 1
F 2
F 3
F 4
Output
: Long Push
Menu Test Preset
V
Local
Off Phase
On Phase
0
1
4
7
2
5
8
3
6
9
V-Limit F-Limit IPK-Limit
F I rms
Cancel
Shift
Range
Enter
Lock
ALM CLR
IPK CLR
Unlock
Surge / Dip
Ramp
TriggerARB
USB A port
Power
switch
Front voltage
output socket
Menu, Test,
Preset keys
LCD
display
Function keys
Display
mode key
Arrow keys,
Scroll wheel
Voltage, Frequency,
Current setting and limit
Keypad
Range, Shift, Cancel,
Enter, Lock keys
Output key
APS-7200 APS-7300
Caster
Adjuster
foot
Caster

GETTING STARTED
15
Item
Description
Power Switch
Turns on the mains power.
Front Voltage
Output Socket
Neutral
GND
Line
Output voltage
terminal using a
regional universal
plug. There is a Euro
and a Universal
regional plug.
CAUTION
Maximum allowable output voltage
and current are 250Vrms and
15Arms.
For voltages exceeding 250Vrms or
current over 15Arms, please use the
rear output terminal.
Universal and EURO region plugs
socket must be factory installed.
USB A Port
The USB port is used for data
transfers and upgrading software.
LCD Screen
Displays the measured values or
menu system.
Display Mode
Select Key
Display
Selects between Standard mode
and Simple mode.

APS-7000 Series User Manual
16
Function Keys
F 1
F2
F3
F4
Assigned to the functions
displayed on the right-hand side
of the screen.
Menu Key
Menu
Enters the Main menu or goes
back to one of the display modes.
Test Key
Test
Puts the instrument into the
Sequence, Simulation and
Program Control mode.
Preset Key
Preset
Puts the instrument into Preset
mode.
Arrow Keys
The arrow keys are used to select
the digit power of a value that is
being edited.
V
V
V-Limit
Used for setting the output
voltage.
V-Limit
(Shift + V)
Used for setting the output voltage
limit value.
F
F
F-Limit
Used for setting the output
frequency.
F-Limit
(Shift + F)
Used for setting the output
frequency limit value.
I rms
I rms
IPK-Limit
Used for setting the maximum
output current.
IPK-Limit
(Shift + I rms)
Used to set the peak output
current limit value.
Range Key
Range
Switches between the 155V, 310V
and 600V ranges (the 600V range
is an option).
Scroll Wheel
Used to navigate menu items or
for incrementing/decrementing
values one step at a time.

GETTING STARTED
17
Lock Key
Lock
Unlock
Locks the number pad to prevent
accidentally changing panel
settings.
Unlock Key
(Long press)
Disables the key lock.
Enter Key
Enter
Confirms selections / settings
Cancel Key
Cancel
Clears entries that are made in the
number entry dialog when a value
is edited using the arrow keys or
the scroll wheel.
The Cancel key can also be used to
cancel function setting menus or
dialogs.
Shift Key
Shift
Turns on the shift state, which
enables shortcut operations.
Output Key
Output
Turns the output on or off.
Number Pad
0
1
4
2
5
8
3
6
9
Lock
Unlock
7
On Phase Surge / Dip IPK CLR
Off Phase Ramp ALM CLR
ARB Trigger
Local
Used to enter values.
Local Mode
(Shift + 0)
Switches operation back to local
mode from remote mode.
ARB Mode
(Shift + 1)
Sets the ARB function.
Trigger Mode
(Shift + 2)
Sets the JI port trigger behavior on
the rear panel.
Off Phase
(Shift + 4)
Sets the off phase for the output
voltage.
RAMP
(Shift + 5)
Quick settings for Ramp control.
ALM CLR
(Shift + 6)
Clears alarms.
On Phase
(Shift + 7)
Sets the on phase for the output
voltage.

APS-7000 Series User Manual
18
Surge/Dip
(Shift + 8)
Quick settings for Surge/Dip
control.
IPK CLR
(Shift + 9)
Clears peak current hold.

GETTING STARTED
19
Rear Panel
SYNC Signal Output LAN
OUTPUT INPUT
L N N L
600Vac MAX. 115 / 230V 15%
50 / 60Hz
3.6kVA MAX.
Out On / Off
COM
J1
Trigger Out
Trigger In
115 / 230V 15%
50 / 60Hz
1.8kVA MAX.
SYNC
SER. NO. LB
L N
600Vac MAX.
Signal Output Trigger Out
Trigger In Out On / Off
COM LAN
J1
OUTPUT
Fan
GPIB
Line voltage input
GPIB
RS232
RS-232/
USB Device
Sync
Signal Output Rear panel voltage
output terminal
Remote control Ethernet port
Line voltage input
APS-7050
APS-7100
Opt. int. port

APS-7000 Series User Manual
20
Remote control
Ethernet port
Line voltage input
APS-7200
GPIB
GPI B
RS 232
RS-232
Fan
Sync
Signal Output
Rear panel voltage
output and
sensing terminals
Optional
interface
port
Circuit
breaker
(current)
USB port
This manual suits for next models
4
Table of contents
Other GW Instek AC Power Distribution manuals

GW Instek
GW Instek ASR-2000 Series Owner's manual

GW Instek
GW Instek APS-7100 Owner's manual

GW Instek
GW Instek APS-7050E User manual

GW Instek
GW Instek APS-7100 Owner's manual

GW Instek
GW Instek ASR-6000 Series User manual

GW Instek
GW Instek APS-7051 User manual

GW Instek
GW Instek APS-1102 User manual

GW Instek
GW Instek APS-1102A User manual

GW Instek
GW Instek ASR-6000 Series User manual