GW Instek ASR-6000 Series User manual

Multi-phase Programmable AC/DC
Power Source
ASR-6000 Series
USER MANUAL
ISO-9001 CERTIFIED MANUFACTURER

This manual contains proprietary information, which is protected by
copyright. All rights are reserved. No part of this manual may be
photocopied, reproduced or translated to another language without
prior written consent of Good Will company.
The information in this manual was correct at the time of printing.
However, Good Will continues to improve products and reserves the
rights to change specification, equipment, and maintenance
procedures at any time without notice.
Good Will Instrument Co., Ltd.
No. 7-1, Jhongsing Rd., Tucheng Dist., New Taipei City 236, Taiwan.

Table of Contents
3
Table of Contents
SAFETY INSTRUCTIONS .................................................. 5
GETTING STARTED.......................................................... 9
ASR-6000 Series Overview ..................................... 10
Appearance ........................................................... 17
Theory of Operation .............................................. 27
OPERATION .................................................................. 38
Set Up ................................................................... 40
Menu Tree ............................................................. 75
Basic Operation..................................................... 79
Advanced Settings ............................................... 120
EXTERNAL CONTROL ...................................................151
External I/O Connector........................................ 152
External Signal Input Function............................. 153
MISCELLANEOUS .........................................................159
T peak, hold ........................................................ 160
Phase Mode......................................................... 162
Peak CLR ............................................................. 164
Power ON............................................................ 166
Buzzer ................................................................. 168
Remote Sense...................................................... 169
V Response.......................................................... 171
Output Relay ....................................................... 172
THD Format ........................................................ 173
External Control................................................... 175
V Unit .................................................................. 176
Set Change Phase ................................................ 177
Monitor Output 1 and 2 ...................................... 178

ASR-6000 Series User Manual
4
Monitor Output Amplitude .................................. 180
Trigger Out Width ................................................ 181
Trigger Out Source .............................................. 184
Re-lock ................................................................ 186
Data Average Count ............................................. 188
Data Update Rate ................................................ 189
TEST MODE FUNCTION ...............................................190
Sequence Mode ................................................... 191
Simulate Mode .................................................... 209
COMMUNICATION INTERFACE ....................................221
Interface Configuration........................................ 222
FAQ..............................................................................243
APPENDIX ....................................................................244
Firmware Update ................................................. 244
Factory Default Settings....................................... 246
Error Messages & Messages ................................ 250
Specifications ...................................................... 255
Information of Name Order ................................. 266
ASR-6000 Dimensions ......................................... 267
Declaration of Conformity ................................... 268
Maintenance & Regular Inspection ...................... 269
INDEX ..........................................................................271

SAFETY INSTRUCTIONS
5
SAFETY INSTRUCTIONS
This chapter contains important safety
instructions that you must follow during
operation and storage. Read the following before
any operation to ensure your safety and to keep
the instrument in the best possible condition.
Safety Symbols
These safety symbols may appear in this manual or on the
instrument.
WARNING
Warning: Identifies conditions or practices that
could result in injury or loss of life.
CAUTION
Caution: Identifies conditions or practices that
could result in damage to the ASR-6000 or to other
properties.
DANGER High Voltage
Attention Refer to the Manual
Protective Conductor Terminal
Earth (ground) Terminal

ASR-6000 Series User Manual
6
Do not dispose electronic equipment as unsorted
municipal waste. Please use a separate collection
facility or contact the supplier from which this
instrument was purchased.
Safety Guidelines
General
Guideline
CAUTION
Do not place any heavy object on the ASR-6000.
Avoid severe impact or rough handling that
leads to damaging the ASR-6000.
Do not discharge static electricity to the ASR-
6000.
Use only mating connectors, not bare wires, for
the terminals.
Do not block the cooling fan opening.
Do not disassemble the ASR-6000 unless you are
qualified.
If the equipment is used in a manner not
specified by the manufacturer, the protection
provided by the equipment may be impaired.
Due to the fact that ASR-6000 unit weights greater
than 18kg, please resort to the standard kit GRA-
451-E for transport or remove the unit by at least
two persons in case of danger occurred.

SAFETY INSTRUCTIONS
7
Power Supply
WARNING
AC Input voltage range:
200 Vac to 240 Vac ±10 %
phase voltage (Delta: L-L, Y: L-N)
Frequency: 47 ~ 63 Hz
To avoid electrical shock connect the protective
grounding conductor of the AC power cord to
an earth ground.
The power switch that is included in the
instrument is not considered a disconnecting
device.
The permanently connected power input is used
as the disconnecting device and shall remain
readily operable.
a. A switch or circuit-breaker must be included
in the installation
b. It must be suitably located and easily reached
c. It must be marked as the disconnecting
device for the equipment.
d. It shall be located near the equipment
Do not position the equipment so that it is
difficult to operate the disconnecting device.
Ask for professional technician for installation.
It requires 200Vac input condition and the
maximum input current [30A (ASR-6450), 40A
(ASR-6600)], which conforms to cord diameter
by local regulations.
Breaker, of which the specification is required to
larger than 30A (ASR-6450), 40A (ASR-6600)
individually, should be in the near proximity of unit.
The ASR-6000 model shall be employed in rack-
based applications and it shall not be connected
to external cord directly. In addition, installation
shall be done by a qualified person in
accordance with local regulations. The ASR-6000
model is not to be used in standalone scenario.

ASR-6000 Series User Manual
8
Cleaning the ASR-
6000
Disconnect the circuit-breaker or permanently
connected power input before cleaning.
Use a soft cloth dampened in a solution of mild
detergent and water. Do not spray any liquid.
Do not use chemicals containing harsh material
such as benzene, toluene, xylene, and acetone.
Operation
Environment
Location: Indoor, no direct sunlight, dust free,
almost non-conductive pollution (Note below)
Relative Humidity: 20%~ 80%, no condensation
Altitude: < 2000m
Temperature: 0°C to 40°C
(Pollution Degree) EN 61010-1:2010 specifies the pollution degrees
and their requirements as follows. The ASR-6000 falls under degree 2.
Pollution refers to “addition of foreign matter, solid, liquid, or
gaseous (ionized gases), that may produce a reduction of dielectric
strength or surface resistivity”.
Pollution degree 1: No pollution or only dry, non-conductive
pollution occurs. The pollution has no influence.
Pollution degree 2: Normally only non-conductive pollution
occurs. Occasionally, however, a temporary conductivity caused
by condensation must be expected.
Pollution degree 3: Conductive pollution occurs, or dry, non-
conductive pollution occurs which becomes conductive due to
condensation which is expected. In such conditions, equipment
is normally protected against exposure to direct sunlight,
precipitation, and full wind pressure, but neither temperature
nor humidity is controlled.
Storage
environment
Location: Indoor
Temperature: -10°C to 70°C
Relative Humidity: ≤90%, no condensation
Disposal
Do not dispose this instrument as unsorted
municipal waste. Please use a separate collection
facility or contact the supplier from which this
instrument was purchased. Please make sure
discarded electrical waste is properly recycled to
reduce environmental impact.

GETTING STARTED
9
GETTING STARTED
This chapter describes the ASR-6000 power
supply in a nutshell, including its main features
and front / rear panel introduction.
ASR-6000 series
ASR-6000 Series Overview ..................................... 10
Series lineup ...................................................................................... 10
Operating Area .................................................................................11
Main Features ................................................................................... 13
Accessories........................................................................................15
Appearance ........................................................... 17
Front Panel........................................................................................17
Rear Panel.......................................................................................... 22
Status Bar Icons ............................................................................... 25
Theory of Operation .............................................. 27
Description of ASR-6000 System .................................................27
Glossary .............................................................................................28
Alarms................................................................................................32
Grounding for 1P2W Output........................................................ 35
Considerations.................................................................................. 36

ASR-6000 Series User Manual
10
ASR-6000 Series Overview
Series lineup
The ASR-6000 series consists of 2 models, the ASR-6450 and ASR-
6600, differing in capacity. Note that throughout the user manual,
the term “ASR-6000” refers to any of the models, unless stated
otherwise.
1P Output Condition
Model Name
Power Rating
Max. Output Current
Max. Output Voltage
ASR-6450
4500 VA
45 / 22.5 A
350 Vrms / 500 Vdc
ASR-6600
6000 VA
60 / 30 A
350 Vrms / 500 Vdc
1P3W Output Condition
Model Name
Power Rating
Max. Output Current
Max. Output Voltage
ASR-6450
3000 VA
15 / 7.5 A
700 Vrms / 1000 Vdc
ASR-6600
4000 VA
20 / 10 A
700 Vrms / 1000 Vdc
3P Output Condition (Pre phase)
Model Name
Power Rating
Max. Output Current
Max. Output Voltage
ASR-6450
1500 VA
15 / 7.5 A
350 Vrms / 500 Vdc
ASR-6600
2000 VA
20 / 10 A
350 Vrms / 500 Vdc

GETTING STARTED
11
Operating Area

ASR-6000 Series User Manual
12

GETTING STARTED
13
Main Features
Performance
Maximum phase voltage is 350 Vrms, line
voltage is 700 Vrms
Maximum DC output voltage is 1000 Vdc
Maximum output frequency is 2000 Hz
Adjustable Voltage rising time
DC full capacity output ability
Output voltage total harmonic distortion is less
than 0.3% at 50 and 60 Hz
Maximum crest factor reached 4 times
Features
Include sine, square, triangle, arbitrary and DC
output waveforms
Variable voltage, frequency and current limiter
100 steps Harmonic voltage and current analysis
ability
Supported three phase unbalanced output mode
Sequence, simulate and preset memory
functions
AC line frequency synchronized output
USB memory save and recall
Remote sense compensator
Supported 1P, 1P3W and 3P output phase
External control I/O and signal input
applications
Voltage and current monitor output
Voltage control amplifier output
PC software, web control and data log functions

ASR-6000 Series User Manual
14
Interface
Built-in LAN, USB host, USB device and RS232
interface
Optional GPIB, DeviceNet and CAN BUS
interface

GETTING STARTED
15
Accessories
Before using the ASR-6000 power source unit, check the package
contents to make sure all the standard accessories are included.
Standard
Accessories
Part number
Description
Quick Start Guide
82GW1SAFE0M*1
Safety guide
62SR-6K0SC401
Input terminal cover
62SR-6K0SC301
Output terminal cover
62SR-6K0CP101
Copper plate for delta
connection input (Mark 1)
62SR-6K0CP201
Copper plate for single phase
and Y connection input (Mark 2)
62SR-6K0CP301
Copper plate for delta
connection input (Mark 3)
62SR-6K0CP401
Copper plate for 1P output (Mark 4)
GRA-451-E
Rack mount adapter (EIA)
GTL-246
USB cable (USB 2.0 Type A - Type
B cable, approx. 1.2M)
Optional
Accessories
Part number
Description
GRA-451-J
Rack mount adapter (JIS)
GPW-008
Power Cord SJT 10AWG/3C, 3m
Max Length, 105oC, RV5-5*3P,
RV5-5*3P UL TYPE
GPW-009
Power Cord H05VV-F
2.5mm2/3C, 3m Max Length,
105oC, RVS3-5*3P, RVS3-5*3P
VDE TYPE

ASR-6000 Series User Manual
16
GPW-010
Power Cord VCTF 2.0mm2/3C,
3m Max Length, 105oC, RVS2-
5*3P, RVS2-5*3P PSE TYPE
GPW-011
Power Cord SJT 10AWG/5C, 3m
Max Length, 105oC, RV5-5*5P,
RV5-5*5P UL TYPE
GPW-012
Power Cord H05VV-F
2.5mm2/5C, 3m Max Length,
105oC, RVS3-5*5P, RVS3-5*5P
VDE TYPE
GPW-013
Power Cord VCTF 2.0mm2/5C,
3m Max Length, 105oC, , RVS2-
5*5P, RVS2-5*5P PSE TYPE
GPW-014
Power Cord SJT 10AWG/4C, 3m
Max Length, 105oC, RV5-5*4P,
RV5-5*4P UL TYPE
GPW-015
Power Cord H05VV-F
2.5mm2/4C, 3m Max Length,
105oC, RVS3-5*4P, RVS3-5*4P
VDE TYPE
GPW-016
Power Cord VCTF 2.0mm2/4C,
3m Max Length, 105oC, , RVS2-
5*4P, RVS2-5*4P PSE TYPE
GTL-232
RS232C cable, approx. 2M
GTL-248
GPIB cable, approx. 2M
ASR-003
GPIB interface card
ASR-004
DeviceNet interface card
ASR-005
CAN BUS interface card
ASR-006
External parallel cable
Note
GPW-008, 009, 010 are for single phase input only.
GPW-011, 012, 013 are for Y connection input only.
GPW-014, 015, 016 are for Delta connection input only.

GETTING STARTED
17
Appearance
Front Panel
F 1
F 2
F 3
F 4
F 5
F 6
F 7
F 8
Programmable AC/DC Power Source
6450
-
ASR
0Lock
Unlock
1
Wave
23
456
78 9
V F I rms
Menu Test Preset
Enter
Cancel
Shift
Range
Off Phase ALM CLR
On Phase IPK CLR
V-Limit F-Limit IPK-Limit
Hardcopy
: Long Push
Output
/
Local
Mode
Phase
1 2 3 4 5 6 7 8
A
9
B
C
D
E
F
GHIJK
Item Index
Description
1
Power switch button
2
USB interface connector (A Type)
3
LCD screen
4
Function keys (blue zone)
5
Menu key
6
Test key
7
Preset key
8
Scroll wheel
9
Range key/Output mode key
A
Arrow keys
B
Output key
C
Shift key

ASR-6000 Series User Manual
18
D
Cancel key
E
Enter key
F
Irms/IPK-Limit button
G
Lock/Unlock button
H
F/F-Limit button
I
V/V-Limit button
J
Numerical Keypad with additional “Shift + key”
shortcut functions (green zone)
K
Air inlet
Item
Description
Power Switch
Turn on the mains power
USB A Port
The USB port is used for data transfers
and upgrading software. Also, it is
available for screenshot hardcopy.
It supports FAT32 format with maximum 32G storage.
LCD Screen
Displays the setting and measured
values or menu system
Function Keys
Assigned to the functions displayed on
the right side of the screen.

GETTING STARTED
19
Menu Key
Enters the Main menu or goes back to
one of the display modes.
Test Key
Puts the instrument into the Sequence
and Simulation control mode.
Preset Key
Puts the instrument into Preset mode.
Arrow Keys
The arrow keys are used to select the digit
power of a value that is being edited.
Range Key
Switches between the 100V, 200V and
AUTO ranges
Output Mode
+
Selects between the AC+DC-INT, AC-
INT, DC-INT, AC+DC-EXT, AC-EXT,
AC+DC-ADD, AC-ADD, AC+DC-Sync,
AC-Sync and AC-VCA modes.
Scroll Wheel
Used to navigate menu items or for
increment/decrement values one step at
a time.
Output Key
Turns the output on or off.
Shift Key
Turns on the shift state, which enables
shortcut operations with an icon
indicated on the top status bar. The shift
state, which allows continuous shortcut
operations, is kept until another press
on shift key again.
When performing shortcut operations, press
shift key followed by another shortcut function
key. Do Not press both shift key and shortcut
function key simultaneously.
Cancel Key
Used to cancel function setting menus
or dialogs.

ASR-6000 Series User Manual
20
Enter Key
Confirms selections and settings.
Irms
Used for setting the maximum output
current.
IPK-Limit
+
Used to set the peak output current limit
value.
Lock/Unlock Key
Used to lock or unlock the front panel
keys except output key. Simply press to
lock, whilst long press to unlock.
F
Used for setting the output frequency
(DC mode N/A).
F-Limit
+
Used for setting the output frequency
limit value (DC mode N/A).
V
Used for setting the output voltage.
V-Limit
+
Used for setting the output voltage limit
value.
Keypad
Used to input power of a value directly.
The key is used to input decimal /
plus or minus.
Other manuals for ASR-6000 Series
1
This manual suits for next models
2
Table of contents
Other GW Instek AC Power Distribution manuals

GW Instek
GW Instek APS-1102 User manual

GW Instek
GW Instek APS-7100 Owner's manual

GW Instek
GW Instek APS-7000 Series User manual

GW Instek
GW Instek APS-1102A User manual

GW Instek
GW Instek ASR-6000 Series User manual

GW Instek
GW Instek APS-7051 User manual

GW Instek
GW Instek ASR-2000 Series Owner's manual

GW Instek
GW Instek APS-7100 Owner's manual

GW Instek
GW Instek APS-7050E User manual