NM283 - Page 4
2
2
3
1
a
a
b
d
e
f
f
c
3. Tension control device operation:
- To turn on the device (1), press the « Start » button (b). The cable tension is displayed for 5 seconds, then the device turn off.
- The device gives the tension in a range from 0 to 10000 (N) with increments of 100 (N).
- When cable set is in tension (quick tensionners red handles closed), without any user on the apparatus, if the cable tension
displayed is less than 1000 or greater than 5000, la LED (d) flashes for 10 seconds. The apparatus should not be used:
for your safety, the cable tension should be in the range of 1000 to 5000.
-IMPORTANT: The device should be assembled on cables with maximum used tension of 10000N. If capacity is
exceeded, the tensiometer displays « Overload » instead of the cable voltage measurement.
4. Supply and charging the tension control device:
- ATTENTION: The device (1) should be only charged with USB charger (4) (supplied with its cable (5)), with 5V DC
output maximum voltage and deliver a current between 1 and 2A.
- When the device (1) is on, the battery load level pictogram « » (e) displays on the right top of the screen (c). Check it
regularly before each use. The black area in this pictogram defines the remaining charge level of the battery, composed
of 20 levels (1 black level = 5% of the battery capacity).
- If the battery reaches an insufficient charge level for use, the bottom line of the screen indicates «Low battery». The device
(1) must then be recharged before any new use, via the USB port (f) located on the side of the device.
- Nota: When the device (1) is powered through its USB connector (f), the display remains active permanently.
- When the device is charging, the display (c) indicates « Charging bat. ».
- When the battery reaches its maximum charge, the display (c) indicates « Bat. charged ».
- As an indication, as part of a regular use of the device (1), it must be recharged approximatively every 6 months (depending
of using).
IV. Maintenance :
- Regular cleaning of the device will make it easier to spot any problems (distortion, play, breakage or corrosion).
- Before each use, make a through check on good condition and correct operation of safety elements: the lack of wear on
the rings (a) and quick links (2), and their locking.
- This device (1) have to be cleaned only with a dry cloth, excluding all cleanup removers which could damage it.
- Check the external appearance of the equipment (1) once a month, which must not show any visible defects (screen (c),
indicator light (d), plastic housing without cracks or other signs of damage).
- Check the proper operation of the alarm once a month, lowering the voltage of the cable on which it is mounted below
the 1000N threshold. The display (c) must indicate a clearly visible voltage value and the light alert must be activated: LED
(d) flashes for 10 seconds.
- The tension control device (1) has to be dismantled from de cable set as less yearly, to remake the « Zero setting » (see § I.)
- If the device (1) is not in use for a period of 3 months or more, charge the device before a new use until the display (c)
indicates that the load is complete (cf. § III. 4.).
Important :
- If a problem or a failure is found or suspected, do not use the equipment until it has been checked by a technician.
- Contact Gymnova with details on the top of first page, or in the «contact» section of the Gymnova website e-shop (https://
shop.gymnova.com/en/nous-contacter).