Hafler PH60B User manual

PH60B
User Guide
Phono Stage
Haer is a division of Radial Engineering Ltd.
1588 Kebet Way, Port Coquitlam
BC, Canada V3C 5M5
(604) 942-1001 info@haer.com
www.haer.com


Table of Contents Page
Features ..............................................................................1-2
Overview ................................................................................ 3
Set the Load ........................................................................... 4
Connect ...............................................................................5-6
Adjusting the Gain .................................................................. 7
Using ...................................................................................... 8
Warranty .................................................................Back Cover
Thank you for purchasing the Haer PH60B™ phono stage,
one of the best sounding and most versatile phono preamps
ever made. The PH60B will boost the signal from your turn-
table and apply the necessary RIAA curve, allowing you to
connect to a HIFI playback system, a pro audio console input
or a recording interface.
Before making any connections, make sure your audio system
is turned off. This will help avoid loud turn-on and connection
transients that can damage more sensitive components such
as tweeters.
The Haer PH60B is designed for a turntable that is equipped
with a moving coil (MC) cartridge, allowing for high quality
playback over balanced or unbalanced outputs. If your turn-
table is equipped with a moving magnet (MM) cartridge, please
consider purchasing the PH50B, which is specically designed
for these types of cartridges.
PH60B PHONO STAGE
USER GUIDE

Hafler
LOW CUT POWER
R
PH60B
LIFT
CE
15VDC · 400mA
GROUND
LEFT RIGHTBALANCED
Hafler is a division of Radial Engineering Ltd.
OUTPUT
LEFT RIGHT
INPUT
LEFT RIGHT
PH60B PHONO PREAMP
FOR MOVING COIL
HaflerR
Hafler
LOW CUT POWER
R
PH60B
LIFT
CE
15VDC · 400mA
GROUND
LEFT RIGHTBALANCED
Hafler is a division of Radial Engineering Ltd.
OUTPUT
LEFT RIGHT
INPUT
LEFT RIGHT
PH60B PHONO PREAMP
FOR MOVING COIL
HaflerR
PH60B PHONO STAGE
Haer
1
FEATURES
1. LOW CUT: Activates the high-pass lter to control low frequencies
2. LIFT: Ground lift on the XLR outputs to remove hum and buzz
3. POWER: Turns on the PH60B
13
2

Hafler
LOW CUT POWER
R
PH60B
LIFT
CE
15VDC · 400mA
GROUND
LEFT RIGHTBALANCED
Hafler is a division of Radial Engineering Ltd.
OUTPUT
LEFT RIGHT
INPUT
LEFT RIGHT
PH60B PHONO PREAMP
FOR MOVING COIL
HaflerR
Hafler
LOW CUT POWER
R
PH60B
LIFT
CE
15VDC · 400mA
GROUND
LEFT RIGHTBALANCED
Hafler is a division of Radial Engineering Ltd.
OUTPUT
LEFT RIGHT
INPUT
LEFT RIGHT
PH60B PHONO PREAMP
FOR MOVING COIL
HaflerR
PH60B PHONO STAGE
Haer
2
9
4
5
6 7 8
4. CABLE CLAMP: Secures the power supply cable
5. 15VDC: external power supply connection
6. BALANCED OUTPUTS: XLR outputs connect to a recording inter-
face or balanced HIFI system inputs
7. UNBALANCED OUTPUTS: RCA output to feed the receiver
8. GROUND LUG: For turntable to eliminate hum and buzz
9. INPUT: RCA input to connect your turntable to the PH60B

PH60B PHONO STAGE
Haer
3
MAGNET
COIL
STYLUS
The Haer PH60B is a combination pre-preamp and RIAA preamp that
both increases the level to accommodate the moving coil, adds in the
RIAA equalization curve and then boosts the signal so that it can be used
by a typical high delity receiver.
ABOUT THE RIAA EQUALIZATION CURVE
The Recording Institute Association of America (RIAA) gured out that in
order to reproduce a vinyl recording effectively, the high frequencies have
to be exaggerated. Upon playback, the reverse lter must then be applied
– resulting in a at and natural sound.
Moving coil cartridges produce a much
lower output than a moving magnet. In
order to bring their gain up to a useable
level, between 60 and 70dB of gain
is required. This in fact is extremely
difcult to do without introducing noise
or artefact. This is why moving coil
preamps are more expensive.
10 Hz
Preamp
Playback
Record
100 Hz 1 kHz 10 kHz
-20
-10
0
+10
+20
-60 dB -10 dB
Receiver Amp
Moving Coil PH60B
OVERVIEW

PH60B PHONO STAGE
Haer
4
SETTING LOAD FOR YOUR CARTRIDGE
The Haer PH60B is set up to accommodate various types of moving
coil cartridges. This is accomplished with a series of internal jumpers
that can be set for 25Ω, 50Ω and 100Ω plus a custom setting should this
be needed.
The PH60B comes factory set at 100Ω as this will accommodate about
90% of the cartridges used today. Your phono cartridge manufacturer
will suggest the appropriate load for its cartridge for optimal performance
– which should be found in the cartridge’s manual or web site. If your
cartridge requires a different load, simply take the cover off the PH60B
using a standard Phillips screwdriver and a HEX 5/64", carefully pull the
jumper from the 100Ω position and push it back on to the 25Ω or 50Ω
position to suit. Setting the load correctly will assure the most accurate
frequency response.
Some cartridge manufacturers may suggest a unique (specic) load to
optimize their cartridge’s performance. To address this, a fourth ‘custom’
position in the jumper section of the PCB allows a resistor to be soldered
in to suit. Simply have your dealer contact the Haer service depart-
ment with the required load and we will calculate the proper resistor. Your
dealer’s service department can then insert the part at a nominal cost to
accommodate your needs.
25 ohms
50 ohms
100 ohms
CUSTOM
25 ohms
50 ohms
100 ohms
CUSTOM

PH60B PHONO STAGE
Haer
5
CE
15VDC · 400mA
GROUND
LEFT RIGHTBALANCED
Hafler is a division of Radial Engineering Ltd.
OUTPUT
LEFT RIGHT
INPUT
LEFT RIGHT
PH60B PHONO PREAMP
FOR MOVING COIL
HaflerR
L R
AUX
AUX
BD/DVD
TUNER
CD
Turn off your system and connect the output from your turntable to
your PH60B. Make sure you use high quality coaxial cables with proper
shielding to minimize noise. It is also very important that you ensure the
ground connection from the turntable is properly and securely fastened
to your PH60B.
Using the Unbalanced Outputs
If you are connecting to a HIFI receiver use the RCA outputs on the
PH50B into a pair of line level inputs on the receiver. Do not use inputs
labeled ‘phono’ as these will apply the RIAA equalization curve a sec-
ond time, resulting in distortion and a loss of high frequencies.
Turntable
Receiver
CONNECT

PH60B PHONO STAGE
Haer
6
CE
15VDC · 400mA
GROUND
LEFT RIGHTBALANCED
Hafler is a division of Radial Engineering Ltd.
OUTPUT
LEFT RIGHT
INPUT
LEFT RIGHT
PH60B PHONO PREAMP
FOR MOVING COIL
HaflerR
L R
AUX
AUX
BD/DVD
TUNER
CD
INPUT
Using the Balanced Outputs
The balanced XLR outputs on the PH60B allow you to connect to de-
vices with balanced inputs, including some home stereo receivers, and
pro audio equipment such as recording interfaces or mixing consoles.
This allows you to set up a turntable for playback in a home theater or
recording studio, or to convert your vinyl collection to a digital format
using recording software. Ensure that you are connecting to inputs that
are set for line-level operation. Once connected, should you encounter
buzz or hum from ground loops, simply engage the LIFT switch on the
front of the PH60B to lift the audio ground on the XLR outputs. The bal-
anced outputs on the PH60B can be set between two different outputs
levels using an internal push-switch. The default setting is +4dB with
the switch in the ‘out’ position, and -10dB with the switch pushed in.
Turntable
Receiver

PH60B PHONO STAGE
Haer
7
The balanced outputs on the PH60B can be set between two different
output levels using an internal push-switch. The default setting is +4dB
with the switch in the ‘out’ position, and -10dB with the switch pushed
in. To access the switch follow the instructions on pg.4 and remove the
necessary screws to open the PH60B.
Most consumer audio devices are set to operate at a -10dB line level,
while pro audio equipment such as mixing consoles and recording in-
terfaces will be set to accept a higher output +4dB level. Check with the
manufacturer of your receiving device to determine whether it operates
at -10 or +4dB.
ADJUSTING THE GAIN
OUT position
+4dB
IN position
-10dB

PH60B PHONO STAGE
Haer
Hafler
LOW CUT POWER
R
PH60B
LIFT
CE
15VDC · 400mA
GROUND
LEFT RIGHTBALANCED
Hafler is a division of Radial Engineering Ltd.
OUTPUT
LEFT RIGHT
INPUT
LEFT RIGHT
PH60B PHONO PREAMP
FOR MOVING COIL
HaflerR
Hafler
LOW CUT POWER
R
PH60B
LIFT
CE
15VDC · 400mA
GROUND
LEFT RIGHTBALANCED
Hafler is a division of Radial Engineering Ltd.
OUTPUT
LEFT RIGHT
INPUT
LEFT RIGHT
PH60B PHONO PREAMP
FOR MOVING COIL
HaflerR
8
USING
The PH60B is equipped with a switchable high-pass lter that can be
activated to eliminate excessive low frequency rumble. This can occur
when listening to music at higher levels. If you encounter rumble, simply
activate the lter. This handy function can also be used to reduce low
frequency transmission to other rooms. Bass energy is much more pow-
erful than mids and highs. Cutting the bass enables you to increase the
volume without causing others as much discomfort.
A cable clamp next to the power jack can be employed to prevent ac-
cidental disconnection. Loosen the clamp, pass the power cable through
and re-tighten.
Gain
Frequency
You are now ready to enjoy 50 years of tradition of building the very
nest audio products for the most demanding high delity enthusiasts.
Hafler
LOW CUT POWER
R
PH60B
LIFT
CE
15VDC · 400mA
GROUND
LEFT RIGHTBALANCED
Hafler is a division of Radial Engineering Ltd.
OUTPUT
LEFT RIGHT
INPUT
LEFT RIGHT
PH60B PHONO PREAMP
FOR MOVING COIL
HaflerR
Hafler
LOW CUT POWER
R
PH60B
LIFT
CE
15VDC · 400mA
GROUND
LEFT RIGHTBALANCED
Hafler is a division of Radial Engineering Ltd.
OUTPUT
LEFT RIGHT
INPUT
LEFT RIGHT
PH60B PHONO PREAMP
FOR MOVING COIL
HaflerR

THREE YEAR TRANSFERABLE LIMITED WARRANTY
HAFLER (A division of Radial Engineering Ltd.) (“Haer”) warrants this product to be free from defects
in material and workmanship and will remedy any such defects free of charge according to the terms
of this warranty. Haer will repair or replace (at its option) any defective component(s) of this product
(excluding nish and wear and tear on components under normal use) for a period of three (3) years
from the original date of purchase. In the event that a particular product is no longer available, Haer
reserves the right to replace the product with a similar product of equal or greater value. In the unlikely
event that a defect is uncovered, please call 604-942-1001 or email service@haer.com to obtain a RA
number (Return Authorization number) before the 3 year warranty period expires. The product must be
returned prepaid in the original shipping container (or equivalent) to Haer or to an authorized Haer
repair centre and you must assume the risk of loss or damage. A copy of the original invoice showing
date of purchase and the dealer name must accompany any request for work to be performed under
this limited and transferable warranty. This warranty shall not apply if the product has been damaged
due to abuse, misuse, misapplication, accident or as a result of service or modication by any other
than an authorized Haer repair center.
THERE ARE NO EXPRESSED WARRANTIES OTHER THAN THOSE ON THE FACE HEREOF
AND DESCRIBED ABOVE. NO WARRANTIES WHETHER EXPRESSED OR IMPLIED, INCLUDING
BUT NOT LIMITED TO, ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR
A PARTICULAR PURPOSE SHALL EXTEND BEYOND THE RESPECTIVE WARRANTY PERIOD
DESCRIBED ABOVE OF THREE YEARS. HAFLER SHALL NOT BE RESPONSIBLE OR LIABLE
FOR ANY SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSS ARISING FROM
THE USE OF THIS PRODUCT. THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS, AND
YOU MAY ALSO HAVE OTHER RIGHTS, WHICH MAY VARY DEPENDING ON WHERE YOU LIVE
AND WHERE THE PRODUCT WAS PURCHASED.
www.haer.com
Haer PH60B™ User Guide - Part #: R870 1312 00 / 08-2017 / V1
Copyright 2017 Haer All rights reserved.
Specications and appearance subject to change without notice.
Table of contents
Other Hafler Amplifier manuals

Hafler
Hafler P505 Owner's manual

Hafler
Hafler 1600 User manual

Hafler
Hafler trans-nova P1000 User manual

Hafler
Hafler T3 User manual

Hafler
Hafler 9303 Owner's manual

Hafler
Hafler JF2000 User manual

Hafler
Hafler 6000 Owner's manual

Hafler
Hafler 9130 series User manual

Hafler
Hafler HA15 User manual

Hafler
Hafler DH-200 Installation instructions

Hafler
Hafler P3100 User manual

Hafler
Hafler CI-1255e User manual

Hafler
Hafler HA75 User manual

Hafler
Hafler 2 Series User manual

Hafler
Hafler XL-600 User manual

Hafler
Hafler trans-nova 9505 User manual

Hafler
Hafler PRO5000 Owner's manual

Hafler
Hafler TRANSNOVA P1500 User manual

Hafler
Hafler GX2800 User manual

Hafler
Hafler TransNova P3000 User manual