Halveon T-Stream MU User manual

MU
The Halveon T•Stream MU could monitoring both
temperature & humidity without installing any
software, end-user could quickly acquire detailed
data reports in both PDF and CSV format.
OPERATING INSTRUCTION
EASY HANDLING
1
and ready to use:
press the START button
to enable Halveon
T•Stream™ MU.
2Insert enabled
Halveon T•Stream™
MU in the delivery.
3Stop logger by
pushing the red button
for 5 seconds (Red led
4Insert the logger
into the USBport and
wait for the data to be
downloaded (Green
light will blinking
and data are ready
PDF & CSV
REPORT
START STOP
START STOP
START STOP
M18007978
M18007978
S/N unique
on double stickers
SIDE
Working statusInformation data
DISPLAY
TEMPERATURE
HUMIDITY
START STOP
Protection
Display
Start/Stop button Led indicator
USB
Connector
FRONT
REAL
DIMENSIONS

MU OPERATING
INSTRUCTIONS
OPERATING INSTRUCTIONS AND INDICATORS
IINSPECTING THE LOGGER
Single press any button or to wake the
device, “READY” means logger is OK for a start.
The battery indicates the power of the logger.
Full power, easy using.
Low power, not suggest using,
be aware the device may possibly stop during
monitoring.
Empty power, cannot be started.
II START THE LOGGER
Device programmed a
start-delay:
Press and hold “START/
STOP” button for more
than 4 secs until the
“CLOCK” icon
appears then release the button within 2 secs, once see the clock
record, and the LCD will turn to “REC.” automatically.
Device not programmed a start-delay:
If the logger doesn’t programme a
“start-delay”, the LCD will show “REC.”
directly, which means start successfully
and is recording now.
III MAKE AND VIEW IN TRANSIT
T•Stream MU loggers provide an option that user could double press
“VIEW/MARK ” button to mark an event at any time during the logger
recording period; the mark will show in the report, the number beside
the indicates the times that has marked, the maximum mark is 8
times.
This optional function mostly used for some important events or urgent
matters happen.
Single-press “VIEW/MARK” button to check the time has been recording
and the MIN / MAX / AVG / MKT temperature and humidity since
The example shows: the logger has been recording 10 days 20hrs
30mins.
IV STOP THE LOGGER
Press and hold “START/STOP” button for more than 4secs until the
“CLOCK” icon appears , then release the button within 2secs to stop,
then LCD will show “STOP” which indicates stop successfully.
Note: if the logger is not stopped manually, the device will continue to
record the data until it is plugged into a USB port on a PC or until the
programmed trip length is reached.
VGET THE REPORTS
Connect the unit to PC, and the LCD will show the progress % of
up automatically with data reports. Also via an OTG line user could
acquire the reports through an Android Smartphone.
VI T•STREAM MU SOFTWARE
HI: Start-delay means a period that device is starting/working but
not recording after delay passed the device will start recording
both means start successfully.
HI: To Start or Stop the device: when hold and press the START/STOP
the action. If continue pressing, the clock will disappear shortly
afterwards which means cancel the action.
T•Stream MU
MU Software Temp/Hum (Multi-Use) V2.4
DEVICE INFORMATION TEMP ALARM
HUMIDITY ALARM
DEVICE STATUS
OTHER FUNCTIONS
TRIP INFORMATION OPERATE
Submit
Notice: device status OK!
Languages Help
Alarm Type: Single
Alarm Delay: 5 Min
Alarm Low: 2 °C
Alarm High: 8 °C
Forbid Manual Stop:
Restart:
Auto Cong:
Hardware Check:
Device Connect:
240 characters maximum, currently characters remaining: 149
S/N: H85080467
Temp. Type: °C °F
Start. Type: Auto
Start. Type: Delay
Start. Delay: 1 Min
Timing: 2019/3/26 12:10:48
Time Zone: UTC+8 2019/3/26 16:18:05
Log Interval: 10 Min
Log Cycle: 30 Min
Points: 4320
Alarm Type: Cumula
Alarm Delay: 5 Min
Alarm Low: 30.0 %
Alarm High: 70.0 %

halveon sagl
via Valdani 1 • CH-6830 Chiasso (Switzerland[email protected] • www.halveon.ch
MU OPERATING
INSTRUCTIONS
VI-1 DEVICE EXAMINATIONS
“T•Stream Software” innovative inspecting function could effectively
Software icon to enter and then connect the device to your computer,
the software will automatically examine the device including battery
power, hardware, and connection status.
VI-2 DEVICE CONFIGURATION
Device information area , each unit has a unique serial number, and
press button to start.
: after the delay period passed, the device will start recording
: the logger will auto-start on a given time.
: the logger will auto-start recording once meet the
selected range.
Select a temperature and humidity range, alarm type and delay time
for the alarm settings.
VI-3 OTHER FUNCTIONS
Type any information in area 5, the info will be presented
on the generated reports. The info could be: customer,
location, order number, etc.
After selected, user cannot stop the device
manually only by connecting the device to a PC and
To restart is the same as start operation.
Note: the orginal data will be formatted once restart,
please acquire the reports before restarting.
just plug in and out, which no need any more operations.
VII TECHNICAL SPECIFICATION
MODEL
T•Stream MU
TYPE
Multi-use
SENSOR
NTC
RANGE
ACCURACY
RESOLUTION
0,1
CAPACITY
BATTERY
3.6v Li
BATTERY LIFE
2-3 years or longer
CALIBRATION
Factory Calibration and NIST CNAS
CERTIFICATION
WARRANTY
1 year
SIZE
106x51x18mm
WEIGHT
65g
WATER-PROOF
IP54
CONNECTION
USB 2.0
SOFTWARE
T•Stream Software
VIII IMPORTANT NOTES
USAGE
temperature before using.
measurement range.
regulations.
BATTERY
tempearture and may lead to destruction of the battery and may cause
injuries.
SECURITY NOTE
LIABILITY
The manufacturer shall not be held liable:
a. If the device was used beyond the manufacturer’s given limitations
b. For any claims due to the imporper storage and use of the deivce
c. For any problems with the cooling unit
d. For the bad quality of the monitored goods, if any.
e. For incorrect readings if the device was used with activated low battery
sign.
ATTENTION: the
T•Stream MU
loggers monitor temperature and humidity
exposure and not the product quality. Its purpose is to signal if product
quality evaluation/testing is required.
HI: Temp & Humidity Alarm is not when temperature exceeds theselected
range will alert in the way of sounding, but to indicates on the LCD
screen and the reports. If no need then un-select the function then
HI: Sometimes due to an aging of PC USB port, or not connect USB port
entirely will lead to a missing. If this happens, please double check
the PC USB port or try another port.

START 5s
STOP 5S
180 Days
Hi: +50°C / +122°F
Lo: -20°C / -4°F
Start Delay: O
WARNING!
Temperature Sensitive Shipment
IN
TO START:
Push the button 5 seconds
The GREEN LED ashes 3 times = ACTIVE
Status LED Flashing
Working Green 1x/30s
Over Red 1x/30s
Under Blue 1x/30s
EXP: (MM/YY)
IN
•Eager to monitor your cold chain and have an answer
at a glance? Then Halveon T•Stream™ IN is the answer to
your request, as it continuously monitors all relevant data.
•The Halveon T•Stream™ IN indicators are specially
developed to monitor the cold chain
in the pharmaceutical logistics.
•As a pre-programmed device the indicator
Halveon T•Stream™ IN can be instantly used to monitor
your temperature sensitive shipments.
•Upon receipt the 3 LED‘s at the front side of the electronic
indicator gives you a fast and clear status of the condition
of your goods.
OPERATING INSTRUCTIONS
1Push Start/Stop button for 5 sec and notice GREEN
LED
2Attach the started
Halveon T•Stream™ IN
to your shipment.
3Push Start/Stop button for 5 sec and notice RED LED
Check the status after receiving the goods.
OK
UNDER Low threshold activated
OVER High threshold activated
OPERATING INDICATIONS
START/STOP
STATUS ACTION LED CONFIRMATION
Start Indicator OK LED•••
Stop Indicator ALERT LED•••
STATUS REQUEST BY PUSHING BUTTON 1 TIME
STATUS ACTION LED CONFIRMATION
Not started OK LEDALERT LED
••
Recording-OK OK LED•
Recording-Low Alarm BLUE LED•
Recording-High Alarm ALERT LED •
Recording-High and
Low Alarm BLUE LED ALERT LED
••
Stopped-OK OK LED ••
Stopped-Low Alarm BLUE LED ••
Stopped-High Alarm ALERT LED ••
Stopped-High and
Low Alarm BLUE LED ALERT LED
••
USING NOTES
1Take care of Expiry date 2Don’t hold the indicator too long in your
3Only for disposable use
OPERATING INSTRUCTION
EASY HANDLING
1Press the START
button to enable
Halveon T•Stream™ IN.
2Insert enabled
Halveon T•Stream™ IN
in the delivery.
3Remove the device
from the delivery, press
STOP to disable it.
4Check the status
of the led after
receiving the goods.
halveon sagl
via Valdani 1 • CH-6830 Chiasso (Switzerland[email protected] • www.halveon.ch
START 5s
STOP 5S
180 Days
Hi: +50°C / +122°F
Lo: -20°C / -4°F
Start Delay: O
WARNING!
Temperature Sensitive Shipment
IN
START 5s
STOP 5S
180 Days
Hi: +50°C / +122°F
Lo: -20°C / -4°F
Start Delay: O
WARNING!
Temperature Sensitive Shipment
IN
START 5s
STOP 5S
180 Days
Hi: +50°C / +122°F
Lo: -20°C / -4°F
Start Delay: O
WARNING!
Temperature Sensitive Shipment
IN
START 5s
STOP 5S
180 Days
Hi: +50°C / +122°F
Lo: -20°C / -4°F
Start Delay: O
WARNING!
Temperature Sensitive Shipment
IN
Led indicators
Start/Stop button
Expiry Date
Glue Spot
Instructions
Barcode label
Other Halveon Measuring Instrument manuals
Popular Measuring Instrument manuals by other brands

Precision Digital Corporation
Precision Digital Corporation PROVU Series instruction manual

METREL
METREL MD 9273 instruction manual

Sigineer Power
Sigineer Power MH-M80 Installation and operation manual

Nivetec
Nivetec Micronics U1000-HM user manual

PT
PT W80158 owner's manual

Tektronix
Tektronix TAP3500 instruction manual

ADInstruments
ADInstruments AD1000 user manual

Spirax Sarco
Spirax Sarco MTI10 Insertion Installation and maintenance instructions

Thingy
Thingy AQ quick start guide

Keysight
Keysight 778D Operating and service manual

Endress+Hauser
Endress+Hauser StamoSens CNM 750 operating instructions

GEONiN
GEONiN DM-100 manual