SPECIFICATIONSSPECIFICATIONS
SPECIFICATIONSSPECIFICATIONS
SPECIFICATIONS
Instruction Manual
www.hannainst.com
DearCustomer,
Thank you for choosing a Hanna Product. Please read the
instructions carefully before using the chemical test kit. It
will provide you with the necessary information for correct
use of the kit.
Remove the chemical test kit from the packing material and
examine it carefully to make sure that no damage has
occurred during shipping. If there is any noticeable dam-
age, notify your Dealer or the nearest Hanna office
immediately.
Each kit is supplied with:
• HI 3859A-0 Glycol Yes/No Reagent, 1 bottle (125
mL);
• HI3859B-0GlycolYes/NoReagent, packets(25pcs);
• HI3859C-0 GlycolYes/NoReagent, packets (25pcs);
• HI 3859 Glycol Standard 0.025%, 1 bottle with
dropper (25 mL);
• 1 plastic pipette (3mL), for HI 3859A-0 Reagent;
• 25 plastic pipettes (1 mL);
• 2 glass vials (10 mL) with cap;
• 1 brush.
Note: Any damaged or defective item must be returned
in its original packing materials.
HI 3859
Glycol Yes/No
Test Kit
ISTR3859 12/99 PRINTED IN ITALY
SIGNIFICANCE AND USESIGNIFICANCE AND USE
SIGNIFICANCE AND USESIGNIFICANCE AND USE
SIGNIFICANCE AND USE
CHEMICAL REACTIONCHEMICAL REACTION
CHEMICAL REACTIONCHEMICAL REACTION
CHEMICAL REACTION
Ethylene glycol and other 1,2 glycols are determined by a
two step reaction:
Step 1: glycol is oxidized to two carbonyl groups under
acidicconditions;
Step 2: the carbonyl groups react with the indicator in
the HI 3859C-0 reagent powder packet to give a
coloredsolution.
Ethylene glycol is widely used as a coolant and antifreeze.
Its presence in motor oils is an indication of a perforated
engine block or of a leakage in the cooling systems. The
Hanna Glycol test kit can be used for water as well as oil
samplesto determine traces of ethyleneglycoland other 1,2
glycols above 30 ppm. For better results test samples from
used motor oil: samples from new oils can give erroneous
positive results. Never test oils from hot engines. Use the HI
3859 Glycol Standard 0.025% included in the Kit to easily
recognize a positive result in the form of an intense purple
color.
Note:Note:
Note:Note:
Note: mg/L is equivalent to ppm (parts per million).
SPECIFICATIONSSPECIFICATIONS
SPECIFICATIONSSPECIFICATIONS
SPECIFICATIONS
Range The test detects traces of glycol
above 30 ppm
Analysis Method Visual/Appearance of color
Sample Size 0.5 mL
Number of Tests 25
CaseDimensions 235x175x115 mm (9.2x6.9x4.5")
Shipping Weight 380 g (13.4 oz.)
READ THE ENTIRE INSTRUCTIONS BEFORE USING THE KIT
Note: to learn how to recognize the pres-
ence of glycol you can use the HI
3859 Glycol Standard 0.025%.
Procedure: add 10 drops of HI 3859
Glycol Standard 0.025% to 0.5 mL
of your sample and follow the in-
structions below: an intense purple
colorwilldevelop.
• Unscrew the cap of the glass vial
and fill it with 5 mL of HI 3859A-0
reagent to the mark using the 3
mL plastic pipette. Add 0.5 mL of
your sample using the 1 mL plastic
pipette.
• Add the content of one packet of HI 3859B-0 reagent,
replace the cap and mix until any solid element is
totallydissolved.
• Wait for 20-25 minutes or place the vial in hot tap
water for 5 minutes.
• Carefully unscrew the vial and add one packet of HI
3859C-0 reagent; replace the cap and mix well until
the reagent is completely dissolved.
• Wait for 75 minutes at room temperature or place the
INSTRUCTIONSINSTRUCTIONS
INSTRUCTIONSINSTRUCTIONS
INSTRUCTIONS
REFERENCESREFERENCES
REFERENCESREFERENCES
REFERENCES
"Advanced Organic Chemistry", J.March, 4th ed. Wiley
Interscience.
HEALTH AND SAFETYHEALTH AND SAFETY
HEALTH AND SAFETYHEALTH AND SAFETY
HEALTH AND SAFETY
The chemicals contained in this test kit may be hazardous if
improperly handled. Read Health and Safety Data Sheets
before performing the test.
vial in hot tap water for 20 minutes.
• Detect the presence/absence of glycol in your sample by
the color developed:
ppmofglycol Color
0-30 yellow-brown
30-75 light purple
more than 75 dark purple
Note:always wait for the final color to be developed. Colors
can turn from
yellow to colorless to light purple (for low range
glycol)
orange to grey/green to dark purple (for high range
glycol)
Note: before performing a new test, rinse thoroughly the
vial under water and clean it by means of the brush
with some soap.
Warning: HI 3859B-0 and HI 3859C-0 reagents can be
disposed as ordinary refuse. HI 3859A-0 reagent
and the content of the vial after use are generally
classified as special wastes. Arrange disposal with a
Chemical Disposal company or contact your Local
Authorities for advice.

Other Hanna Instruments Chemical Test manuals

Hanna Instruments HI 3826 User manual

Hanna Instruments

Hanna Instruments HI 3826 User manual

Hanna Instruments HI 38061 User manual

Hanna Instruments

Hanna Instruments HI 38061 User manual

Hanna Instruments HI 3824 User manual

Hanna Instruments

Hanna Instruments HI 3824 User manual

Hanna Instruments HI 38051 User manual

Hanna Instruments

Hanna Instruments HI 38051 User manual

Hanna Instruments HI 3810 User manual

Hanna Instruments

Hanna Instruments HI 3810 User manual

Hanna Instruments HI 3833 User manual

Hanna Instruments

Hanna Instruments HI 3833 User manual

Hanna Instruments HI 3854 User manual

Hanna Instruments

Hanna Instruments HI 3854 User manual

Hanna Instruments HI 3880 User manual

Hanna Instruments

Hanna Instruments HI 3880 User manual

Hanna Instruments HI 3856 User manual

Hanna Instruments

Hanna Instruments HI 3856 User manual

Hanna Instruments HI 3849 User manual

Hanna Instruments

Hanna Instruments HI 3849 User manual

Hanna Instruments HI 3851 User manual

Hanna Instruments

Hanna Instruments HI 3851 User manual

Hanna Instruments HI 38013 User manual

Hanna Instruments

Hanna Instruments HI 38013 User manual

Hanna Instruments HI 38016 User manual

Hanna Instruments

Hanna Instruments HI 38016 User manual

Hanna Instruments HI 93754C-25 HR User manual

Hanna Instruments

Hanna Instruments HI 93754C-25 HR User manual

Hanna Instruments HI 38001 User manual

Hanna Instruments

Hanna Instruments HI 38001 User manual

Hanna Instruments HI 98103 User manual

Hanna Instruments

Hanna Instruments HI 98103 User manual

Hanna Instruments HI 3820 User manual

Hanna Instruments

Hanna Instruments HI 3820 User manual

Hanna Instruments HI 3832 User manual

Hanna Instruments

Hanna Instruments HI 3832 User manual

Hanna Instruments HI 38042 User manual

Hanna Instruments

Hanna Instruments HI 38042 User manual

Hanna Instruments HI 3879 User manual

Hanna Instruments

Hanna Instruments HI 3879 User manual

Hanna Instruments HI764 User manual

Hanna Instruments

Hanna Instruments HI764 User manual

Hanna Instruments HI 3873 User manual

Hanna Instruments

Hanna Instruments HI 3873 User manual

Hanna Instruments HI 38073 User manual

Hanna Instruments

Hanna Instruments HI 38073 User manual

Hanna Instruments HI 755 User manual

Hanna Instruments

Hanna Instruments HI 755 User manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.