3. Secure the End Cap with the 4 to 6 (black) sheet metal screws (FIG. 2).
4. Replace the (silver) pivot screw in the center of the End Cap.
Mount the HPX into the Mounting Surface
Caution: Do not use a high-powered torque screw driver. Over-tightening these screws
can damage the product.
Note: For detailed instructions on installing the HPX base assembly, refer to the HPX-
600/900/1200/1800 and HydraPort Touch (7”/10”) Installation Guides (available
online at www.amx.com).
1. Carefully insert the HPX base into the cutout in the mounting surface.
2. Tighten the four mounting screws (FIG. 6) located inside and at each end of the
HPX base assembly, to rotate the retaining tabs (FIG. 7) into locking position
under the mounting surface.
3. Feed the excess cable up through the mounting collar and insert the cable
cartridge hook into the mounting collar cutout.
4. Push the cable cartridge trigger up onto the mounting collar tongue until it
latches (opposite of FIG. 4).
5. Use the Push button to retract the cable into the cartridge.
6. Attach the display ends of the cables as necessary.
7. Use cable ties to secure cable bundles as necessary.
Note: Use of an extension cable on the display end of this cable can be achieved
using the AMX DP-HDMI Adapter and HDMI Extender (FG558-21) to ensure optimal
performance. See “DP-HDMI Adapter” on page 2.
Existing Installations
For existing HPX installations, the HPX Base Assembly must be removed from the table
surface before the Retractable Cable Modules can be installed:
1. Cut/remove any cable ties that would restrict the removal of the HPX Base Assembly.
2. Loosen the four mounting screws located inside and at each end of the HPX base
assembly (FIG. 6), to rotate the retaining tabs from under the mounting surface.
Note: When the cover of the HPX base is open, only two of these screws are visible.
To access the other two screws, tip the cover over to the opposite open position.
3. Once the retaining tabs have been rotated out from under the mounting surface,
the HPX assembly can be lifted away from the mounting surface.
FIG. 7 provides a cutaway view of the End Cap, showing the retaining tabs
highlighted in both the loose position and the tightened (secure) position.
4. Return to the installation section at the bottom left column of page 1 to continue
with installing the RCM into the HPX Base assembly.
Mounting Dimensions
FIG. 8 provides dimensions for the retractable cable module, when installed in an HPX
base assembly:
MyTurn™ Source Selector Button
The HPA-MYT-TX MyTurn™ Source Selector Button
(FG554-21) clips into the specially designed groove
built into the end of a MyTurn ready cable. Users
press to send the content on their device to the
display. When pressed, the button transmits a signal
to a receiver (FG554-23) that plugs directly into an
AMX switching device such as a Solecis SDX, Enova
DVX, or NX Series Controller.
MyTurn Source Selector Buttons are illuminated briefly when that specific device is
selected, making it easy to determine whose content is being shown on the display at
any given time. Refer to the HPA-MYT-TX documentation for further details
Replacing HPX-AV102-MDP-R
Removal of the HPX Base assembly
is not required to replace this RCM:
1. Detach the cable cartridge
from the mounting collar.
2. From the top of the mounting
collar, press a small flat blade
screwdriver into the notch on
the split side of the pop out
panel and pop it out of place.
3. Slip the cable out through the slot in the mounting collar panel.
4. Replace with new RCM in reverse order ensuring the cable is not twisted and the
pop out panel split is oriented towards the notch in the collar.
DP-HDMI Adapter
The DP-HDMI adapter (FIG. 11) is included
with the HPX-AV102-DP-R DisplayPort
4K60 Module with Retractable MyTurn
Ready Cable. Plug it into the end of the
DisplayPort cable to connect to
HDMI ports
on some displays or the AMX HDMI Extender
(
FG558-21
).
Additional Documentation
Refer to the Products > Architectural Connectivity catalog page on www.amx.com
(Dealer Site) for additional product documentation.
FIG. 6 HPX BASE ASSEMBLY (SHOWN MOUNTED) - MOUNTING SCREWS LOCATIONS
FIG. 7 HPX BASE ASSEMBLY (SHOWN MOUNTED) - MOUNTING SCREWS LOCATIONS
Retaining tab
(to secure the unit)
shown tightened
Retaining tab
(to remove the unit)
shown loosened
FIG. 8 RCM MODULE (INSTALLED IN AN HPX BASE) - DETAILED DIMENSIONS
5 ft Cable Pigtail
HPX Base Assembly Top
Mounting Surface Top
Removable RCM
cable cartridge
mounted to
(285.3 mm)
11.2 inches
(200.6 mm)
7.9 inches
Removable RCM
mounting collar
mounted to HPX
Base
mounting collar
Mounting Collar
Pop-out panel
Slip cable through
slot in panel
Notch in collar
FIG. 9 MYTURN SOURCE SELECTOR
FIG. 10 RCM MOUNTING COLLAR POP-OUT PANEL
FIG. 11 DP-HDMI ADAPTER