Vent Congurations:
To reduce probability of reverse drafting during shut-
down conditions, Hearth & Home Technologies strongly
recommends:
• Installingthepelletventwithaminimumverticalrunof
vefeet,preferablyterminatingabovetheroofline.
• Installingtheoutsideairintakeatleastfourfeetbelowthe
venttermination.
Topreventsootdamagetoexteriorwallsofthehouseand
topreventre-entryofsootorashintothehouse:
• Maintainspeciedclearancestowindows,doors,andair
inlets,includingairconditioners.
• Ventsshouldnotbeplacedbelowventilatedsofts.Run
theventabovetheroof.
• Avoidventingintoalcovelocations.
• Ventsshould not terminate under overhangs,decks or
ontocoveredporches.
• Maintain minimum clearance of 12 inches from the
ventterminationtotheexteriorwall.Ifyouseedeposits
developing on the wall, you may need to extend this
distancetoaccommodateyourinstallationconditions.
Hearth & Home Technologies assumes no responsibility
for, nor does the warranty extend to, smoke damage
caused by reverse drafting of pellet appliances under
shut-down or power failure conditions.
WARNING! DO NOT CONNECT THIS UNIT TO ANY AIR
DISTRIBUTION DUCT OR SYSTEM.
Ifarearexituecongurationisused,withorwithoutoutside
air, make sure the ue pipe termination clearances are
followedasperNFPA211.
Vent Pipe
Besure to use approved pelletvent pipe wall andceiling
pass-throughttingstogothroughcombustiblewallsand
ceilings.Besuretouseastartingcollartoattachtheventing
systemtothestove.Thestartingcollarmustbesecuredto
theuestubwithatleastthreescrews,andsealedwithhigh
tempsiliconecaulking.
4” stainless steel ex vent piping is only allowed for use
inmasonryreplacesandchimneysorfactorybuiltwood-
burningreplaceswithclassAmetalchimneys.
Pellet venting pipe (also known as Type PL vent) is
constructedoftwolayerswithairspacebetweenthelayers.
Thisairspaceactsasaninsulatorandreducestheoutside
surfacetemperature to allow a clearance to combustibles
of only 1 inch. The sections of pipe lock together to form
anairtightsealinmostcases;however,insomecasesa
perfect seal is not achieved. For this reason and the fact
thattheAccentra52iPelletInsertoperateswithapositive
ventpressure,wespecifythatthejointsalsobesealedwith
silicone.
Wherepassingthroughanexteriorwallorroof,besuretouse
theappropriatepass-throughdeviceprovidinganadequate
vaporbarrier.Ventingmanufacturersgenerallyprovidethese
pas-throughdevices.
Venting Termination Requirements
1. Termination must exhaust above air inlet elevation.
It is recommended that at least 60 inches (1524mm)
of vertical pipe be installed when appliance is vented
directly through a wall. This will create a natural draft,
whichwillhelppreventthepossibilityofsmokeorodor
ventingintothehomeduringapoweroutage.Itwillalso
keep exhaust from causing a nuisance or hazard by
exposing people or shrubs to high temperatures. The
safest and preferred venting method is to extend the
ventverticallythroughtheroof.
2. Distance from doors and operable windows, gravity or
ventilationairinletsintobuilding:
a. Notlessthan48inches(1219mm)below;
b. Notlessthan48inches(1219mm)horizontallyfrom;
c. Notlessthan12inches(305mm)above.
3. Distancefrompermanentlyclosedwindows:
a. Notlessthan12inches(305mm)below,horizontally
fromorabove.
4. Distance between bottom of termination and grade
should be 12 inches (305mm) minimum. This is
conditionaluponplantsinthearea,andnatureofgrade
surface.Thegradesurfacemustbeanon-combustible
material(i.e.,rock,dirt).Thegradesurfacemustnotbe
lawn.Distancebetweenbottomofterminationandpublic
walkwayshouldbe84inches(2134mm)minimum.
5. Distance to combustible materials must be 24 inches
(610mm) minimum. This includes adjacent buildings,
fences,protrudingpartsofthestructure,roofoverhang,
plantsandshrubs,etc.
6. TerminationCapLocation(HomeElectricalService)
• Side-to-side clearance is to be the same as minimum
clearancetovinylinsidecorners.
• Clearanceofaterminationcapbelowelectricalservice
shallbethesameasminimumclearancetovinylsofts.
• Clearanceofaterminationcapaboveelectricalservice
willbe12inches(305mm)minimum.
• Location of the vent termination must not obstruct or
interferewithaccesstotheelectricalservice.
For Canada Only: This Fireplace Insert must be
installed with a continuous chimney liner of 4”
diameter extending from the replace insert to the top
of the chimney. The chimney liner must conform to the
Class 3 requirements of CAN/ULC-S635, Standard for
Lining Systems for Existing Masonry or Factory-Built
Chimneys and Vents, or CAN/ULC-S640, Standard for
Lining Systems for New Masonry Chimneys.