Harmopool ZWMX7510-P User manual

Geassembleerddoor:
ZwembadBVBA
Industrieweg9
3190Boortmeerbeek
België
www.harmopool.eu
MicrodosPooltwinwatertreatmentonplate
ZWMX7510‐P

Tableofcontents
Introduction
............................................................................................................................3
Specifications...........................................................................................................................4
Installation...............................................................................................................................5
Installationitems.................................................................................................................5
Installationofthewatertreatmentplate...........................................................................6
Winterready........................................................................................................................8
Springstartup......................................................................................................................8
Maintenance........................................................................................................................9
Warnings..............................................................................................................................9

3
Introduction
Thismanualcontainsallthenecessaryinformationforinstallation,errormessages,
dischargeandmaintenance.Readthemanualcarefullybeforeyouopentheunit.The
manufacturerofthisproductwillnotbeheldresponsibleforinjuriesordamagetothe
productresultingfromanincorrectinstallation,dischargeorunnecessary
maintenance.Itisessentialthattheinstructionsinthismanualarealwaysfollowed
carefully.Qualifiedpersonnelmustinstallthisproduct.
○
Onlyaqualifiedinstaller,center,personnelorarecognizeddealermayrepairthis
product.
○
Maintenanceandservicemustrespecttherecommendedtimeandfrequency,as
mentionedinthemanual.
○
Onlyusetheoriginalspareparts.Failuretodosowillvoidthewarranty.
Characteristics
○
Durability
:Themostfrequentlyusedproductsarechlorine,acid(sulfuricacid)and
baseresistant.
Thesecanresistlong‐termexposuretoswimmingpoolwater(even
withsaltforsaltelectrolysis).Theseperistalticpumpsarenottobeusedwith
sulfuricacid(HCI)
○
Easy‐use
:Theunitisveryeasytouse:TurnitonandsetthepH(acid)orredoxvalue
(chlorine).
○
Lowcost
:Withcorrectusetheswimmingpoolwaterwillneverturngreen,keeping
operationalcostslow.

4
Specifications
ZWWX7510‐P
pHregulation MicrodosSpeedypH
Chlorineregulation MicrodosSpeedyChlorine
Poolconnection 50mmrubber
Flowswitchsafet
y
O
p
tional
Platemeasurements 50x50cm

5
Installation
Installationitems
Thefactoryonlyprovidestheplatewithwatertreatmentapplianceswithoutplugs.
Warning!
○ Theelectricalconfigurationshouldbeasfollows:
‐ Thechlorineandacidpumpscan’tworkifthefilterpumpisdisabled.
‐ Beingabletodisablethechlorineandacidpumpsifthefilterpumpisenabled.
○ Chemicalsshouldbeaddeddownstreamofpoolaccessoriessuchasheating,UV‐
lighting,filtersetc.
○ Combiningchlorineandacidcanresultinchlorinegas.Ensurethatthechemicalsare
placedoutsideandtheydon’tcomeincontact.
○ Itisrecommendedtosetthewatertreatmentunittobypassmode.
○ Installthewatertreatmentunitonastableplatform.
○ Alwayskeeptheunitstraight.Iftheunithasbeentiltedorplacedonitsside,the
electrodescan’tfunctioncorrectly.
○ Theunitmustbeinstalledinside.Ifyouwishtoinstallyourunitoutside,pleasecontact
yoursupplier.
○ Donotplacesulfuricacidinthedispensers(HCl)
○ Acidandchlorine(liquidchlorine)maynotbemixed.Mixingwillresultinchlorinegas.
Carefullystorethechemicalssotheydonotcomeincontact.
○
Theelectricalpartsoftheunit(thedispensers)mustbeinstalledinside.Ensurethat,
incaseofaleakage,theunitwillremainunaffected.
○ EnsurethatthechlorineandacidcontainersareplacedOUTSIDEorinawellventilated
area.

6
Installationofthewatertreatmentplate
1Connectthewatertreatmentplatetoastablewall.
2ConnecttheinletandtheoutletsothewaterpassesbythepHandredoxmeasurement
electrodes,thenpastthedispensercaps.
Ifthewaterintheunitisheadingtheoppositeway,simplyunclickthemeasurementand
dispensertubes,turnthemaroundandreclick.
Bypassconfigurationispreferred:
3Connecttheelectricalcomponentsasfollows:
‐ Thechlorineandacidpumpscan’tworkifthefilterpumpisdisabled.
‐ Beingabletodisablethechlorineandacidpumpsifthefilterpumpisenabled.

7
4PlacepHandchlorineelectrodesintheelectrodeholders.
5Startthefilterpump
6Verifythattheinstallationisnotleaking
7CalibratepHandredoxelectrodes,consulttheStandardautomaticpH‐dosagemanuals
(onlypHmin)‐ZWMX2140andtheStandardautomaticchlorinedosage‐ZWMX2152.
Ifyouhavenobypassconfiguration,youshouldplacetworubbercapsZFPX4640inthe
electrodeholderstopreventwaterfromsprayingoutduringconfiguration.
8Configurethesetpointsfortheinstallation.PHwillbesetto7.4andredoxat700mV.
Aftertheprimarystartup,measurethepHandchlorinelevelswithacolormethod.Change
thesetpointforredoxifnecessary(lowerifchlorinelevelsaretoohigh,increaseif
chlorinelevelsaretoolow).Consultthefollowingmanuals:StandardautomaticpH‐
dosage(onlypHmin)‐ZWMX2140andStandardautomaticchlorinedosage‐ZWMX2152.
9PlacethechlorineandpHsuctioncapsinthecorrectchlorineandacidtubes.Avoid
lettingthecapsinktothebottomofthetube.Thisway,theentiretubeofchlorineoracid
won’tgetpumpedintothepoolincaseofanerror.
10Starttheinstallationbyenablingtheelectricityforthepumpandthedosageappliance.

8
Winterready
Warning!Failuretoprotectyourproductagainstthewintercanresultindamageandthe
warrantydoesnotcoverthis.
Inareaswithalotoffrost,makesuretoprotectthepump,filteranddosageapplication
fromfreezing.
Itisrecommendedtostoretheappliancesinawarmanddryarea.
Theelectrodesmustbestoredfrost‐free,inKClliquid.
Depvc‐tubesmustbedried.
Thewhitedosinghoseinthedosingdevicemustbereplacedpreventivelyeveryyear.In
theeventofhosebreakage,thechemicalsflowintothedosingpumpwiththeriskof
irreparabledamagetothedosingpump.
Ingeneralthereare5mechanismsthroughwhichthedosingtubecanbreak:
A.Thetubeisattheendofitslife(withchemicalcompatibility)after500/600hoursof
performance
B.Determinationofincompatibleproductswiththe"Santoprene"materialofthetube(PH
regulationwithHCI)
C.Increaseofchemicals.Bottlewithclingandacidonthepumps/pumpsmountedonthe
verticalbus.
D.Backflowblocksofthepumporinjectionblockedbylimestone(moreoftenin
calcareouswaters.
E.Emptydosingvessel,asaresultofwhichtheperistalticpumpkeepsrunningandthe
500/600hoursofrunningtimecanbereachedveryquickly.
Springstartup
Ifyourunitwasprotectedagainstthewinter,usethefollowingstepspriortorestarting
yourproductforspring:
1. Recalibratetheelectrodes
2. Verifythatthecheckvalvesinthedosagenippleisn’tstuck.
3. Verifythattherearen’tanyleakswhentheunitisunderpressureandwhenthe
dosagepumpsareon.

9
Maintenanceandinspection
Maintenance
o RegularlyverifythefunctionalityoftheelectrodesandthesettingsbymeasuringpH
andchlorinelevelswithanalternativemethod(colormeasurement)Ifnecessary,
adjustthesettings.
o Regularlyverifythetubeinsideoftheperistalticpump.Immediatelyreplacethistubeif
thereisanyleakagepresent.Itisrecommendedtoreplacehistubeona2‐yearbasis.
o Regularlycheckthenozzlesforleaks.Immediatelyreplaceiftheyleak.
o Regularlycheckthenozzlesforblockage.Immediatelyreplaceiftheyleak.
o Checkthepowersupplyandcableconnectionfrequently.Ifthepumpstarts
functioningabnormally,disableitandcallatechnician.
Warnings
○ Incorrectinstallationcancauseachemicalorelectricalrisk,whichcanresultinserious
injuries.
○ Nevermixacidwithliquidchlorine.
○ Keeptheunitandchemicalsoutofthereachofchildren.Alwayswearsafetygloves
andglasseswhenconfiguringtheunit.
○ DONOTATTEMPTtoadjustthedosageapparatusinternally.
○ Ifyou’reunfamiliarwithswimmingpoolfiltersanddosageapparatus:
Donotattempttoadjustanythingwithoutconsultingyoursupplieroratechnician.
Readtheentireguidethoroughlybeforeadjustingthedosageapparatus.
Note:Disablethecurrentpriortorepairsormaintenance.
Table of contents
Other Harmopool Swimming Pool Filter manuals
Popular Swimming Pool Filter manuals by other brands

Innovative Water Care
Innovative Water Care Pulsar Precision 30 System Operation and installation manual

RADLEY
RADLEY 5044-794 user guide

Bestway
Bestway AQUAFEED owner's manual

Zodiac
Zodiac TRi PRO Module Instructions for installation and use

Zodiac
Zodiac eXO Manual addendum

Aseko