Model 9321/9321CE/9326/9326CE/9327/9327CE
IMPORTANT SAFETY INFORMATION
READ ALL INSTRUCTIONS BEFORE USING
11. In accordance with NEC guideline, this water heater is
designed for a continuous duty cycle of 3 hours
at 100% power output. Exceeding this rating could
damage the heater and void the warranty.
12. Provide your heater with potable, uninterrupted supply of
water at a constant minimum pressure of 35 PSI
(2.4 bar) (based on model) and maximum pressure of 150
PSI (10.3 bar).
13. Use of Water Hammer Arrestors in applications required;
neglecting to do so will damage the heater and void the
warranty.
14. This heater must be in a location where it is not subject to
freezing temperatures unless supplied with factory installed
freeze protection.
15. Properly purge air out of system before power is applied.
Recommended to purge water through system for
minimum 2 minutes at a minimum 15 gpm (57 lpm),
closing and opening drain valve 3 times to move any
lodged air before power is applied.
16. This appliance is not intended for use by persons unless
they’re certified personnel or have been given proper
instruction and supervision.
17. This appliance cannot be played with by children. Install
to prevent children from playing with or around the
appliance.
18. Cleaning and user maintenance should only be per-
formed by trained and licensed professionals.
19. Sanitation models used in a circulator system, a 30
second factory set delay program will be installed
to establish flow before power is applied. Contact Haws
for information at +1-800-766-5612 or Haws - EMEA at
P: + 41(0)34 420 60 00
20. Applications with the use of a recirculation circulator must
be installed according schematics.
21. The use of Ethylene glycol antifreeze is strictly
prohibited. Propylene Glycol is the only recom-
mended antifreeze.
06/23 Page 3 of 32
1. You must read and follow all instructions. Serious bodily
injury or death could occur if you ignore this warning.
2. All circuit breakers and/or disconnect switches servicing
the heater must be turned off when installing, uninstall-
ing, or repairing this water heater.
3. The unit must be installed by a licensed electrician and
plumber.
4. The unit must be wired in accordance with the current
version of the National Electrical Code (US), Canadian
Electric Code (Canada) or IEC International Standards.
5. This installation must comply with all national, state, and
local plumbing and electrical codes.
6. When the heater is not within sight of the electrical circuit
breakers, an additional local means of disconnec-tion of
all ungrounded conductors must be provided that is
within sight of the appliance or a circuit breaker lockout
must be used. (Ref. NEC 422.31)
7. Per UL 499, this water heater is not required to be
installed with a Temperature and Pressure relief valve
(T&P). However, local codes may vary. In case a T&P relief
valve is required, it must be installed on the outlet hot
water line heater between the heater and the isolation
valve.
8. If the Haws tankless water heater is installed in a location
where water damage could occur in the event of a leak, it
is recommended that a drip pan be installed and
connected to a suitable drain. Alternatively, an active
water leak detector and shut off valve can be installed to
turn off your water supply in the event a leak is detected.
9. If water supply has a high mineral content, a water
softening system is recommended. Damage to the water
heater resulting from scale or hard minerals will not be
covered under warranty.
10. When the heater is installed in a well water system or if
the plumbing system is prone to introducing air into the
heater, it is highly recommended that an air sep-arator be
installed in the cold water feed to the heater to avoid
possible failure of the heating element and/or heating
chamber.