Healthy Climate HCWB3 User manual

INDOOR AIR QUALITY
HCWB3
Healthy Climate®
By-Pass Humidier
Bulletin No. 210543
September 2011
Supersedes May 2011
Model Number Identification
HCWB 3 - 17 A K
Unit Type
HCWB = Healthy Climate By-Pass Humidier
Nominal Capacity
12 = 12 US Gallons per day
17 = 17 US Gallons per day
Controls
(blank) = Manual Humidistat
A = Automatic Humidier Control
Installation Kit
K = Installation Kit Furnished (Canada only)
WARRANTY
All covered components - limited warranty for ve
years in residential applications, one year in non-
residential applications.
Refer to the Lennox Equipment Limited Warranty
certicate included with the unit for additional details.
APPROVALS
Units are UL listed per ANSI/UL 998 and CSA C22.2
No.104-01.
APPLICATIONS
Applicable to most forced air installations.
Installs on the supply air plenum with a by-pass
duct from the return plenum in upow and horizontal
applications. Installs on the return air plenum with
a by-pass duct from the supply plenum in downow
applications. See Typical Applications.
Provides additional humidity to the home during the
heating season to increase comfort level.
Do not install where freezing may occur.
Humidier, saddle valve and manual or automatic
humidier control (depending on model) shipped in one
package.
Sequence of Operation
Humidier will only operate when indoor blower is
operating.
When the level of moisture in the return air or living
space area drops below the set point of the humidier
control, the water solenoid valve opens, water ows
into distribution tray and weeps down through the
evaporator pad. By-pass air ows over the evaporator
pad, increasing the humidity of the air, and then back
into the return air stream. When the humidier control
is satised the water solenoid valve closes.
FEATURES
PRODUCT SPECIFICATIONS
Series
Automatic Humidier Control
(furnished with “A” Models)
Manual Humidistat
(furnished with standard Models)

HCWB3 − By-Pass Humidier / Page 2
FEATURES
Cabinet
Rugged, corrosion resistant molded plastic.
Humidier is shipped for left-hand by-pass duct
connection.
For right-hand by-pass duct connection, rotate
humidier cabinet 180º top for bottom and relocate
drain spud. See Installation Instructions for additional
details.
Built-in damper included to close off bypass duct during
summer cooling operation.
CONTROLS
Manual Humidistat - HCWB3-12 and HCWB3-17
Can be horizontally mounted on wall or duct.
Provides manual control of room relative humidity.
Wired in series with the humidier water solenoid
valve.
Adjustable setting.
Automatic Humidier Control - HCWB3-12A and
HCWB3-17A
Duct mount only.
Automatic or manual mode control. Manual Mode label
(with resistor to bypass outdoor temperature sensor)
are furnished to indicate when humidistat is installed in
Manual Mode.
Senses duct air relative humidity and outdoor
temperature. Includes outdoor temperature sensor
for use with automatic control option and resistor for
manual control setting.
Adjusts humidity setpoint to provide optimum humidity
levels within the space.
Adjustable setting.
WATER SUPPLY
Consists of supply tubing, orice, distribution tray,
cleanable/replaceable internal strainer and 24 volt
brass water solenoid valve with stainless steel seat.
Drain
1/2 in. drain tting at bottom of cabinet.
1/2 in. ID plastic tubing must be eld provided.
Unused water from the evaporator pad is drained from
the unit to help remove mineral deposits left from the
evaporative process.
Distribution Tray
Reservoir and unique polyester liner provides even
water distribution across the evaporator media pad for
optimal performance.
Tray and support frame removable for cleaning or
replacement.
Evaporator Media Pad
Provides large evaporation capacity.
Pad and support frame removable for cleaning or
replacement.
Annual pad replacement recommended.
Saddle Valve
All necessary ttings furnished as standard equipment.
Field installs in the water supply line
OPTIONAL ACCESSORIES
Healthy Climate® Digital Automatic Humidistat
Basic humidity control (on/off or proportional) and
temperature display.
Control Buttons:
• Power button
• °F/°C display
• Set button for changing
humidity setpoints.
• SLEEP button for
changing day/night
modes.
• PRG button for programming timed settings and
setting the clock.
• Up/Down buttons to change humidity setpoint and
time.
Built-in humidity sensor.
Outdoor temperature sensor furnished.
24VAC powered directly by the humidier.
LCD with alphanumeric characters and icon graphics
for Humidity and Temperature (indoor/outdoor),
Humidity Mode, Sleep Mode, Auto Mode, Lock Mode,
Program Timer On.
Large LCD display shows humidity (or temperature)
setpoint while the small display shows temperature (or
time) setpoint.
Built-in clock (with backup) for automatic humidity
control. Two time settings per day.
Error code display.
Lock mode indicates a parameter has been set.
Dimension (H x W x D): 3-3/8 x 5-1/2 x 1-3/8 in.

HCWB3 − By-Pass Humidier / Page 3
OPTIONAL ACCESSORIES (continued)
Healthy Climate® Water Conductivity Test Kit
A conductivity meter is recommended for testing the
water.
Measures total
dissolved solids
(TDS) and
temperature.
Automatic
Temperature
Compensation (ATC).
Water-resistant housing
Measurement Range: 0-5000 ppm
Digital Calibration (Push button)
Auto-off function, data-hold function and low-battery
indicator.
Display: large and easy-to-read LCD screen includes
simultaneous temperature reading.
Factory-calibrated with a 342 ppm NaCl solution. The
meter can be recalibrated with digital calibration using
the Push buttons, rather than a screwdriver.
Includes cap and CR2032 battery.
Bypass Humidier Installation Kit
Note - Furnished as standard with “K” models for
Canada Only
Kit contains: 3 ft. of exible bypass duct (6 in. dia.),
bypass duct collar (6 in. dia.), 15 ft. of drain tubing (1/2
in. I.D.), 10 ft. of poly water supply tubing (1/4 in. O.D.)
rated for water supply line, 10 ft. 24V low voltage wire,
hose clamps (2), brass tubes (2) and ferrule plastic
tubes (2).
See Optional Accessories table for catalog number.
MAINTENANCE SUPPLIES
Replacement Media
Recommended annual replacement of media pad.
See Optional Accessories table for catalog number.
FEATURES
SPECIFICATIONS
Model No. With Manual Humidistat Control HCWB3-12 HCWB3-17
With Automatic Humidier Control HCWB3-12A HCWB3-17A
1 With Manual Humidistat Control and Installation Kit (Canada) HCWB3-12K HCWB3-17K
1 With Automatic Humidier Control and Installation Kit (Canada) HCWB3-12AK HCWB3-17AK
Capacity - 120°F plenum temperature, 0.20 in. w.c. static pressure drop 12 US gallons per day 17 US gallons per day
Water Feed Rate (gallons per hour @ 50 PSI water pressure) 3 3
Evaporator pad size - H x W x D - in. 9-1/2 x 9-5/8 x 1-11/16 13 x 10 x 1-11/16
Connections Plenum H x W - in. 9-1/2 x 9-1/2 12-3/4 x 10
By-Pass Duct - in. 6 round 6 round
Water supply 1/4 in. compression 1/4 in. compression
Drain 1/2 in. I.D. 1/2 in. I.D.
Electrical characteristics 24V-60Hz, 0.5 amp 24V-60Hz, 0.5 amp
Shipping Data - lbs. (1 package) 8 9
MAINTENANCE SUPPLIES - MUST BE ORDERED EXTRA
Replacement Media X2660 X2661
OPTIONAL ACCESSORIES - MUST BE ORDERED EXTRA
Healthy Climate® Digital Automatic Humidistat Y3760 Y3760
Healthy Climate® Water Conductivity Test Kit Y3480 Y3480
Bypass Humidier Installation Kit (Not available in Canada) Y2960 Y2960
1 Canada only.

HCWB3 − By-Pass Humidier / Page 4
DIMENSIONS - INCHES (MM)
− For upflow/horizontal applications air flow is from the humidifer to return air duct.
FRONT VIEWLEFT SIDE VIEWBACK VIEW
9-1/2 (241)
OPENING
12
(305)
1-1/2
(38)
1-3/4
(44)
A
6-1/8 (156) DIA.
BY−PASS DUCT
CONNECTION
B
OPENING
1
AIR FLOW
NOTES:
By-pass duct air flow direction is dependent on application.
− For downflow applications, air-flow is to the humidifier from the supply air duct.
1 Left hand air inlet/outlet shown. For right-hand inlet/outlet, rotate humidifier cabinet 180º top for bottom and relocate
drain to alternate location on cabinet. See Installation Instructions for additional details.
DRAIN
SOLENOID
VALVE
SUMMER / WINTER
DAMPER CONTROL
C
Model No. A B C
in. mm in. mm in. mm
HCWB3-12(A)(K) 12-7/8 327 9-1/2 241 10-1/4 260
HCWB3-17(A)(K) 15-7/8 403 12-3/4 324 10-1/2 267
TYPICAL APPLICATIONS
HUMIDIFIER
HORIZONTAL UNIT
SUPPLY
AIR
RETURN
AIR
UP−FLOW UNIT
HUMIDIFIER
RETURN
AIR
SUPPLY
AIR
DOWN−FLOW UNIT
RETURN
AIR
SUPPLY
AIR
HUMIDIFIER

HCWB3 − By-Pass Humidier / Page 5
HUMIDIFIER SIZING INFORMATION
(BASED ON VOLUME OF HOME)
Model No. Type of Home 8 Foot Ceiling 9 Foot Ceiling 10 Foot Ceiling
Home Area (sq. ft.) Home Area (sq. ft.) Home Area (sq. ft.)
HCWB3-12(A)(K)
Loose 750 666 600
Average 1500 1350 1200
Tight 3000 2700 2400
HCWB3-17(A)(K)
Loose 1000 888 800
Average 2000 1800 1600
Tight 4000 3600 3200
NOTES:
Loose Home = Two Air Change Rates per hour: Typically, loose in construction and is over 20 years old. Not very well insulated and may
have single pane windows, etc.
Average Home = One Air Change Rate per hour: Average in construction, 15 to 20 years old on average.
Tight Home = One-Half Air Change Rate per hour: Newer home with tight construction..
Also see Healthy Climate Power Humidier HCWP3 Product Specications for additional sizing conditions if needed.



NOTE - Due to Lennox’ ongoing commitment to quality, Specications, Ratings and Dimensions subject to change without notice and without incurring liability.
Improper installation, adjustment, alteration, service or maintenance can cause property damage or personal injury.
Installation and service must be performed by a qualied installer and servicing agency. ©2011 Lennox Industries, Inc.
Visit us at www.lennox.com
For the latest technical information, www.lennoxdavenet.com
Contact us at 1-800-4-LENNOX
REVISIONS
Sections Description of Change
Optional Accessories Added Healthy Climate® Digital Automatic Humidistat and Healthy Climate® Water Conductivity
Test Kit.
This manual suits for next models
8
Table of contents
Other Healthy Climate Humidifier manuals
Popular Humidifier manuals by other brands

Stadler Form
Stadler Form POSEIDON operating instructions

Trane
Trane HUMD500A Safety instructions and installation template

Hoffrichter
Hoffrichter Aquapoint operating instructions

Nordmann Engineering
Nordmann Engineering Omega Pro Series installation manual

Honeywell
Honeywell HE105 installation instructions

Holmes
Holmes HM5601 owner's guide