heatwell TR8100V User manual

TR8100V Thermos tat Instructions
ver 1.0
LCD symbols
See overleaf for further setting up information
Setting the clock and day of the week
This thermostat is fitted with a real time clock. It is essential that the clock time and day are set accurately if you require your programmed events
1) Touch the time display and the time will start flashing.Use the up and down arrows to set the time.By holding the arrow down the time will change faster.
2) Press to move to the Day setting and use the up and down arrows to get to the correct day.
3) Press to store and exit.
to start on time. To set follow the steps below:
Page1
The buttons are locked
Heating is turned on
Automatic mode,
Manual mode
executes the programmed schedules
The floor sensor is not being read by the thermostat
Err
Temporary temperature override
Frost protection activated
AUTO
Override
Symbol SymbolEvent Event
Program number
Economy temperature
Comfort temperature
Configuration Menu
To enter into the setting menu please follow the steps below:
Step 3, Use the up and down arrows to adjust the sensor selection which is Menu 01(Air sensing;Air and Floor, or Floor only)
Step 4, Press to move to the next Menu and once you have all the menu options set,
Setp 5, Press to accept and store.
Step 1, Turn the thermostat off by pressing ;
Step 2, Press , you will then see menu 01.
POWER
NEXT
NEXT
DONE
DONE
MENU
This thermostat is a combination model which allows you
to choose 3 different modes.
A mode = Air Sensing Only(Has built in sensor)
AF mode = Air & Floor sensing(
Floor probe must be installed)
F mode = Floor Sensing(Floor probe must be installed)
Menu #
01 Mode/Sensor selection
Switching Differential
Air Temp Calibration
Floor Temp Calibration
Temperature Readout
(AF mode only)
Maximum Floor Temp
( AF mode only)
Temperature Format
Clock Format
24 (default), 12- hour or 24-hour clock format
02
03
04
05
06
07
08
09
10
Feature Explanation Adjustment
1
°C, 2°C....10°C ( 1°C by default)
-1
°C
= decrease 1
°C
, 1
°C
= increase 1
°C
...
-1
°C
= decrease 1
°C
, 1
°C
= increase 1
°C
...
A= to show air temperature, F=to show floor temperature,
A--F = to show both in 5 second intervals
20
°C~
40
°C
(40
°C
by default)
C or F
A, AF, F
(press up & down buttons to adjust)
The number of degrees difference before switching.
The default is 1°C which means the thermostat will switch
the
heating on 0.5°C below the set temperature and will turn
it off 0.5°C above the set temperature.With a 2°C differential
the heating will switch on 1°C below the set temperature
and will switch off 1°C above the set temperature.
This is to recalibrate the air temperature if required.
This is to recalibrate the floor temperature if required.
This gives you the option to show the Air Temperature,
Floor Temperature or to show both Air & Floor at intervals.
This is to protect the floor surface.
This alows the temperautre to be set to show °C or °F.
You can select the clock to show in either 12 or 24 hour time
5+2 / 7 Day Mode
This allows you to program either 5 days at once, then the
2 days of the weekend separately, or a full 7 days at the
same time or 7 days separately
Frost Protection on= activated, off= deactivated
01 = 5+2 day programmable
02 = 7 day programmable
This is to avoid your room temperature going below 5
°C

Setting the Program Schedules
This thermostat has the ability to program each individual day of the week separately, or program 7 days of the week at once. You can also program weekdays
Set to the time you would like to wake to and the temperature you want during the morning, until you left for the day.
Press and the day display will start flashing. (If your thermostat is set to 5+2 day programmable mode, the programming will skip to step3)
Use to adjust the day of the week you want to start programming or to the day you wish to edit an existing event / program.
(Press to select all 7 days of the week, and to cancel press again.)
Press
Use and to adjust the time you wish the Program 1 event to commence for the selected day/days.
Press and the temperature will start flashing.
Use and to set the desired temperature to be maintained during Program 1.
Press and the LCD screen will show Program 2 with the time display flashing, this signifies that the second daily event is now ready to be programmed.
Repeat steps 4,5,6 to set the remaining programs/events, then press to store and exit.
Hint: During setting programs, press will clear a program entry and thermostat will maintain the temperature setpoint of the last executed program
Above are default program schedules, to make changes, follow easy steps as below.
Set to the time you leave home and the temperature you wish your home to maintain while you are away at work perhaps.
Set to the time you return home at end of the day and the temperature you want during evening until bed time.
Set to the time you sleep and the temperature you want overnight(usually a comfortable and energy saving temperature).
07:00
1
2
3
4
22 °C
16:30 22 °C
09:30 16 °C
22:30
1.
2.
3.
4.
5.
6.
7.
16 °C
WAKE
Program Start Time Setpoint Explanation
LEAVE
RETURN
SLEEP
the LCD screen will show Program 1( ) and the time will be flashing.
Page 2
This product should be installed by
a qualified electrician.
Installation and Wiring
Carefully separate the front half of the thermostat from the back plate by placing a small
flat head terminal driver into the slots on the bottom face of the thermostat.
Carefully unplug the ribbon connector which is plugged in to th
e front half of the thermostat.
Place the thermostat front half somewhere safe. Terminate the t
hermostat as shown in
the
diagrams below.
Screw the thermostat back plate on to the flush box
Re-connect the thermostat ribbon cable and clip the two halves together.
LL
LOAD (16A)
FEED
(230VAC)
Floor Sensor
NN
Thermostat Instructions
ver 1.0
until the beginning of the next program.
NEXT
NEXT
NEXT
DONE
DONE
DELETE
SCHEDULE
ALL DAYS ALL DAYS
Temporary Temperature Override
Touch the temperature display, and it will start to flash. Use up or down
buttons to adjust. Press to accept, and you will see “Override”
above the temperature display. Thermostat will maintain the new set
Lock the Keypad
To lock the keypad, press and hold the top left corner of
display for 5 seconds,
you will see a lock symbol . To unlock, repeat the steps above and the
Reset to Factory Setting
With thermostat turned off,
press and hold OFF for
5 seconds until you can
DONE
RUN
SCHEDULE
see -- : -- on LCD.
temperature until the next programmed event(comfort level). To cancel
the override setting, press
Auto / Manual Mode
Holiday Function
MODE
HOLIDAY
Press to select Auto/Manual mode. In Manual mode( ), the
thermostat maintains
a constant set temperature manually set by the user.
In Auto mode, the thermostat executes the preprogrammed schedules.
Press , enter the duration of your holiday by or .
Press . To cancel a Holiday,reduce the holiday period to 00 days.
The Holiday function reduces the temperature in your room to the frost protection
temperature. The thermostat will maintain this temperature for the duration of the
holiday and will then automatically return to the program mode on your return.
(5 days) to one schedule and then weekends (2 days) to a different schedule. See the Menu information for details on how to set this up.(refer to Menu 10)
lock symbol will disappear.
TR8100V
Table of contents
Other heatwell Thermostat manuals