HEIRLOOM NEXUS User manual

NEXUS
NZAust v1.
6
MW
Page
1
of
3
NEXUS
LADDER TOWEL WARMER
For
Warm
F
luffy
T
owels
Operation
Your
NEXUS
Towel Warmer uses only minimal electrical power
-
about the same as an average
light bulb. It will take approximately 20
-
30 minutes to reach maximum operating temperature.
NEXUS
Towel warmers are designed for continuous operation. NOTE: The temperature of your
towel warmer will vary with the ambient temperature of your room. A towel warmer is designed to
warm and assist the drying of towels and will normally operate at a temperatu
re that is too hot for
the warmer to be grasped for an extended time.
Locating Instructions
Detailed installation instructions are provided on the reverse side. The
NEXUS
Ladder Towel
Warmer should be fixed through the wall cladding directly to studs or o
ther suitable anchor
material.
The towel warmer should be located in compliance with the AS/NZS 3000 Standard and
should not in any circumstances be located in the direct path of a water source (tap or shower
etc).
NEXUS
towel warmers have an IP45 rating o
ffering you the greatest flexibility to safely
locate the towel warmer in bathrooms or shower rooms in
Zone 1
-
3
. All other electrical fittings
must also be compliant with the zone within which the warmer is being installed.
Electrical Installation
Please
ensure your towel warmer is installed by a registered electrician
and ensure the electrical
supply, plug & switch location, and product location will comply with your local regulations.
New Zealand electrical wiring requirements stipulate that this applia
nce must be wired by a
registered electrician in accordance with current electrical wiring r
eg
ulations. This appliance must
be fitted with an air gap phase isolation switch
which isolates the phase & neutral in accordance
with local wiring regulations
.
Thi
s product must be used in
c
onjunction with a hard wired
switch
.
For complete temp
erature control a wall mounted dimmer switch (with “off” position) is
recommended.
Concealed Wiring Kit
A concealed wiring adapter kit is
included with
this product. If you h
ave access to the wall cavity
the kit allows you to conceal the electrical flex for a more
s
treamline
d
and
v
isually appealing
installation.
Care and Cleaning
The polished
stainless steel
finish of your Towel Warmer is hard wearing and easily maintained.
C
lean
regularly
with a soft clothand non
-
abrasive cleaning agent.
Guarantee
This product is guaranteed against defects due to fault
y workmanship or materials for
5
years
from date of purchase. In the event of a defect in the product, it should be returned
with the sales
receipt to the retailer from whom it was purchased. Under the guarantee the defective article will
be repaired or replaced at Heirloom’s option
–
free of charge. Costs of disconnection,
reconnection, and freight are the responsibility of th
e owner, as is any damage arising in transit to
and from servicing.
This guarantee does not cover:
a.
Any damage to the product caused by misuse, neglect, accident, or in violation of the
manufacturer’s instructions, or
b.
Any damage, loss or injury arising as
a consequence of the use of the product.
Contact Us
We welcome your feedback on our products. You can view our full range of towel warmers on our
website and send us your comments about this product to
info@heirl
oom.co.nz
.
Heirloom
International Limited
,
P O Box
204 235
Manukau 2161
, New Zealand.
www.heirloom.co.nz

NEXUS
NZAust v1.
6
MW
Page
2
of
3
INSTALLATION OF
NEXUS
LADDER TOWEL WARMER
SPECIFICATIONS
Mounting Centre
(Approx
Width)
Rating at 24
0 Volts AC
Voltage
IP Rating
Model
W
HN
825 (7 Rungs)
570mm
90
Watts
230
-
240VAC
IP
4
5
Model
W
HN
825S (7 Rungs)
Slimline
420mm
68
Watts
230
-
240VAC
IP
4
5
Model
W
HN
510E (5 Rungs)
820
mm
8
8
Watts
230
-
240VAC
IP
4
5
This Package Contains:
1 Ladder Towel Warmer
1 x Concealed adaptor fixing barrel (optional)
Electrical Flex
4 x Mounting Screws to fix Fixing Barrel to wall
2 x Top Mounting Legs with Fixing Barrel & Grub Screw & (Separate) Fixing bolt
1 x Bottom Mounting Leg (Non Flex Leg) with Fixing Barr
el & Grub Screw
1 x Bottom Mounting Leg (Flex Leg) with Plastic Trim & Flat Fixing Bracket & Grub Screw
CAUTION:
Prior to installation please ensure the product is to your satisfaction. Once installed Heirloom cannot be responsible for
defects in the p
roduct finish. This product is not intended for use by young children or infirmed persons without supervision. Young
children should be supervised to ensure they do not play with the product. To minimize a hazard for young children, this appl
iance
should b
e installed so that the bottom rail is 600mm above
the floor.
If the supply cord is damaged it must be replaced by the
manufacturer, its service agent, or similarly qualified persons in order to avoid a hazard
.
Installation:
This towel warmer
must
be ins
talled by a registered electrician and in accordance with local and national electrical codes. We
recommend that the towel warmer be installed vertically on a flat and uniform wall, and where possible into studs or other su
itable
anchor material. If fixing
to hollow cavity walls, Toggle Anchors (not those supplied) or similar devices must be used.
Position the towel warmer so that the plug and mains power receptacle are easily accessible, with the cable entry to the towe
l
warmer NEAREST THE FLOOR. Avoid th
e supply cable coming into contact with the heated parts of the towel warmer.
DO NOT PLUG THE UNIT INTO THE POWER SUPPLY OR SWITCH THE TOWEL WARMER ON BEFORE INSTALLATION IS
COMPLETE.
1
If the towel warmer is being installed with a concealed electric flex
, read those instructions before returning to this point
as preparatory work is required before the wall cladding is installed onto the walls.
2
Identify the three different types of mounting legs per the above descriptions and attach the two top mounting le
gs to the
towel warmer with the fixing bolts (After removing the fixing barrels
& making sure the grub screw will face the floor)
3
Decide which side the electric flex is to be connected and then connect the “Non Flex” Leg to the bottom of the towel
warmer t
hat will not house the electric flex (After removing the fixing barrel
& making sure the grub screw will face the
floor
). Also before attaching the leg, make sure the cap that covers the electrical connection/wires is in place.
4
Thread the “Flex Leg” on to
the electric flex (ensuring that the leg is facing in the correct direction). On the foot that will
receive the electric flex, remove the cap from the electric flex that protrudes from the towel warmer. Plug in the electric
flex and firmly secure it by scr
ewing together
the two pieces of the connector fitting
. Fix the leg to the towel warmer
with
the
two screws provided
.
5
If the warmer is being installed without using the concealed adaptor (i.e. The electric flex is to be visible) proceed to the
next step. I
f the towel warmer is being installed with a concealed wiring fixing adaptor, proceed to that section.
6
Hold the towel warmer in position and mark around one of the top legs. Remove the towel warmer and fix the fixing
barrel to the wall.
7
Place the leg onto
the fixing barrel and, making sure that the towel warmer is level, mark the location of the remaining
top leg. Fix the fixing barrel to the wall
8
Place the towel warmer onto the two fixing barrel’s and mark the location of the two bottom legs.
9
Remove the t
owel warmer and fix the remaining fixing barrel and fixing bracket to the wall. Ensure that the metal fixing
bracket is used for the foot that contains the electric flex . (The other three feet will use the same style of fixing bracke
t)
10
Ensure the flex exi
ts the leg through the slot with the plastic edge.
11
Place the towel warmer in position and secure it to the fixing barrels using the grub screws.

NEXUS
NZAust v1.
6
MW
Page
3
of
3
Concealed Wiring Option Instructions
:
The concealed
wiring adaptor
is to
be installed
before
the wall cl
adding is in position.
1.
Ensure that the flush box that the towel warmer will be wired to is within this distance of the mounting position of the
foot of the towel warmer that has the flex. Allow for loss of flex length due to connections.
2.
Drill a
12.5
mm h
ole into the face of the stud where the towel warmer foot with the flex is to be positioned. Drill the
hole approximately 25mm deep.
3.
Identify the side of the stud facing the flush box that the towel warmer will be wired to. On that side of the stud, drill
a 25mm deep hole at right angles to this first hole so that the hole will break into the base of the first hole. Refer to
Fig1.
9.
Place a pull through line from the flush box to the
12.5
mm hole that can be picked up later once the wall cladding is i
n
place
10.
Once the wall cladding is positioned, remove some of the cladding to expose the
12.5
mm hole. Locate the pull through
and thread the adaptor
-
fixing barrel onto the pull through.
11.
Screw the adaptor
fixing barrel
into the stud. On masonry walls dril
l a 1
4
mm hole and epoxy resin the adaptor
-
fixing
barrel into position. The shoulder of the barrel should leave a gap equal to the wall cladding thickness so that when the
wall cladding is fixed the shoulder of the barrel is flush with the wall cladding. (r
efer Fig
2
)
12.
Mark a point horizontally from the centre of the adaptor at the measurement for your model (
but check the actual
measurements to your warmer as manufacturing tolerances apply)
for the other bottom fixing barrel. It is important that
the line
between these two points is level
.
13.
Screw the other fixing barrel (provided with the towel warmer) into place with the screw provided with the towel warmer.
14.
Attach the pull through to the flex and pull the flex through the stud holes
to the flush box.
15.
Position the towel warmer on the bottom two fixing barrels and mark the two top feet. (Use easy to remove pencil)
16.
Mark the centre distance for the top fixing barrels (per above) & screw the fixing barrels to the wall.
17.
Remount the towel
warmer on the four fixing barrels. Secure the foot containing the
flex with the screw provided t
hen
secure the three remaining feet with the screws provided
.
At centre measurement
for your model
This manual suits for next models
3
Table of contents
Other HEIRLOOM Bathroom Fixture manuals
Popular Bathroom Fixture manuals by other brands

Franke
Franke ANIMA ANMX500 Installation and operating instructions

Tres
Tres QUADRO 092.865.51 manual

Radaway
Radaway Korfu A Assembly instructions

Toto
Toto TX454SESMR installation manual

aquabrass
aquabrass 97019 installation guide

Hans Grohe
Hans Grohe Rainfinity 100 1jet 26866 Series Assembly instructions

Mirabelle
Mirabelle St. Martin MIRSM4RTGCP quick start guide

Symmons
Symmons Museo 532HSB Operation & maintenance manual

Franke
Franke RODAN RODX605EE Installation and operating instructions

Hans Grohe
Hans Grohe 27418 Series Instructions for use/assembly instructions

alfi
alfi AB1472 manual

Tenzo
Tenzo CTS-1317LW-CR Installation manual & users guide