ModelHDS-200/300
4-1. TROUBLESHOOTINGGUIDE
Productnot • Coldwellor hot wellnot • Checkplugsunder table-top
holding plugged-in on frenchfry end ofHDS-300
temperature • Productheldtoolong • Onlyholdproductfor
recommendedtimes
• Coldwellsettingturned • Turncontrolsettingto about 6
• Compressoroverheated • Cleancondensercoil
• Product not a proper • Be sure product is at proper
temperaturewhenplaced temperature
intounit
• Defectivefuseforrefrigeration • Replace15 amp fuse
unit
Refrigerationunitruns • Frostbuild-up • Defrostunit
constantly • Condensorcoildirty • Cleancondensercoil
Powerswitchon but • OpenCircuit • Plugunitin
nopowerto unit • Checkcircuitbreaker
• Check15 ampfuses
• Checkcord andplug
forlooseconnection
Notalllights • Faultylightbulbs • Replacewithnewbulb,
on perLightBulbReplacement
Section
Lightswill • Defectivefuse • Replace15 amp fuse
notturnon
PROBLEM CAUSE CORRECTION
SECTION 4. TROUBLESHOOTING
4-1 605