Cleaning and checking
9Maintenance instructions
4 Cleaning and checking
DANGER Risk of personal injury and property damage from electric shock
• Before working on the unit, ensure that the unit is dead.
• Do not operate the unit with the housing open.
CAUTION Risk of falling from unstable climbing aids
• Use only approved ladders or step stools as climbing aids.
CAUTION Risk of burns from hot surfaces
Allow the unit to cool down before maintenance.
Only carry out maintenance on a unit that has cooled down.
CAUTION Risk of injury from sharp edges
• Wear protective gloves.
NOTICE Risk of physical damage to activated charcoal filter from incom-
plete filter materials
Operate unit only with fully inserted filter materials.
INFORMATION A slight discoloration of the filter materials does not indicate the degree of soil-
ing or functional capability.
It is not an indication of poor quality.
4.1 Cleaning intervals
The cleaning intervals depend on the manner and intensity of
combisteamer use.
For average use the manufacturer recommends the following cleaning
intervals
•Condensation area under the grease filter – clean once a week
•Grease filter – clean every 4 weeks
•Filter mat (yellow) – clean or replace every 2 months
•Air filter – replace every 12 months
•Activated charcoal filter – visual inspection annually
FM05-229