HID Corporation ThinLine II 5395B User manual

____________________________________________________________________________________________
HID Corporation 9292 Jeronimo Road Irvine, CA 92618-1905 USA TEL (949) 598-1600 (800) 237-7769 FAX (949) 598-1690 Web
page, E-mail - www.prox.com ThinLine II Reader Installation Manual 5395-901 REV B 1of 5
Installation Manual - 5395-901 Rev B
ThinLine II Reader - 5395B
Проектирование. Монтаж. Продажа. - http://vskd.ru

____________________________________________________________________________________________
HID Corporation 9292 Jeronimo Road Irvine, CA 92618-1905 USA TEL (949) 598-1600 (800) 237-7769 FAX (949) 598-1690 Web
page, E-mail - www.prox.com ThinLine II Reader Installation Manual 5395-901 REV B 2of 5
ThinLine II Reader Installation Manual - System Overview
The ThinLine II Reader is a self contained proximity Reader frequently used in Access Control Systems.
The antenna and all associated electronics are assembled in a polycarbonate housing. The Reader
contains a micro-controller unit that controls an RF field that is generated at 125kHz. The Reader has a
sensitive receiver circuit that detects ID card data and passes it along to the micro-controller for
decoding. The Reader output is configured in the "Wiegand" style electrical interface. The Reader has a
single Bicolor LED that will emit red, green or amber colors. Installation of the ThinLine II Reader
consists of mounting the Reader and connecting the cable to the Host via the Pigtail cable.
Operation
Access Cards are to be presented to the front of the Reader. The LED is red when ready to read an ID
card. The LED turns green when the card is read and a message is transmitted to the Host computer or
interface panel. When the system is ready for another card, the LED returns to red. The is LED is
flashed green and the Beeper is activated for 250 milliseconds when they are controlled by the internal
micro-controller. The operation of the LED and beeper is often controlled by the Host panel. If Host
controlled, the operation will deviate from Host to Host. The ThinLine II may be configured in the dual
LED control line that allows individual control of both the red and green colors of the LED.
Parts List Quantity
1) ThinLine II 1 (included)
2) #6-32 x 1" self tapping, Type T or 23 2 (included)
3) This Installation Sheet 1 (included)
4) Wire Splice 9 (installer supplied)
5) Grommet 1 Recommended (installer supplied)
6) DC Power Supply - +4.75 to 16VDC, 50mA 1 (installer supplied)
7) Cable, 5 conductor , 22 AWG Up to 500ft. (installer supplied) Alpha 1295C
Installation Procedure
1. Determine an appropriate mounting position for the Reader. Drill two 7/64th (.109) Inch holes for
mounting the Reader to the surface. Drill a 3/8 to 1.0 Inch hole for the cable. If mounted on metal,
place a grommet around the edge of the hole. Route the interface cable from the Reader and/or
power supply to the Host. Check all electrical codes for proper cable installation.
2. The ThinLine II is available with either a 15” Pigtail or a 2 meter Pigtail, as shown in the
configurable options/ordering information, below. To make the cable connection, prepare the new
cable by cutting the cable jacket back 1-1/4” and strip the wires ¼”. Splice the cable and the pigtail
together and seal the splice if the ThinLine II will be an outdoor unit. Trim and cover all conductors
that are not used.
3. Connect the Reader and Host together according to the wiring diagram (below) and the Host
installation guide. The legend for wiring is color coded (according to the "Wiegand Standard") for
the recommended cable, but marking the wires will make future maintenance easier. The color of
the legend on the back label is the color of the respective wire.
4. After wiring the Reader and power supply, the Reader is ready to be tested. Power up the Reader
and the LED and Beeper will flash and beep 3 times in a sequence of two short delays and one
long delay. This indicates that the micro-controller unit is working properly. Present an ID card to
the Reader and the LED should momentarily turn green, indicating a read of the card. If the
Reader LED is controlled by the Host refer to the Host description of the LED operation.
5. Mount the Reader with the provided screws when mounting onto spacers or junction boxes. On
other materials use the appropriate fastener.
Проектирование. Монтаж. Продажа. - http://vskd.ru

____________________________________________________________________________________________
HID Corporation 9292 Jeronimo Road Irvine, CA 92618-1905 USA TEL (949) 598-1600 (800) 237-7769 FAX (949) 598-1690 Web
page, E-mail - www.prox.com ThinLine II Reader Installation Manual 5395-901 REV B 3of 5
Dimension Diagrams, front and side views
3.00
4.663.32
2 PLCS, .155 X .215
SLOT, .312 X .31
DEEP COUNTERBORE
.50
TOLERANCES: .XX +/- .03"
.XXX +/- .010"
Back views
+
that may cause undesired operation.
FCC ID: JQ6536X
ELECTRICAL RATING: 5-12VDC/50mA
ACCESS CONTROL SYSTEM UNIT
REFER TO OPERATORS MANUAL
interference recieved, including interference
following two conditions: (1) This device
FCC rules. Operation is subject to the
may not cause harmful interference, and
This device complies with part 15 of the
(2) This device must accept any
LISTED ACCESSORY.
5395-901.
R
8T29
GREEN LED (ORANGE)
5-12 VDC (RED)
GROUND (BLACK)
DATA0/DATA (GREEN)
DATA1/CLOCK (WHITE)
SHIELD GROUND (DRAIN)
RED LED (BROWN)
BEEPER (YELLOW)
HOLD (BLUE)
CARD PRESENT (VIOLET)
U.S. PATENT NO. 4,730,188
1996 HID CORPORATION
C
ThinLine II
HID CORPORATION
R
+
R
ThinLine II
U.S. PATENT NO. 4,730,188
1996 HID CORPORATION
C
HID CORPORATION
ACCESS CONTROL SYSTEM UNIT
REFER TO OPERATORS MANUAL
ELECTRICAL RATING: 5-12VDC/50mA
8T29
LISTED
R
5395-901.
ACCESSORY.
FCC ID: JQ6536X
that may cause undesired operation.
following two conditions: (1) This device
FCC rules. Operation is subject to the
(2) This device must accept any
interference recieved, including interference
may not cause harmful interference, and
This device complies with part 15 of the
SHIELD GROUND (DRAIN)
BEEPER (YELLOW)
GREEN LED (ORANGE)
RED LED (BROWN)
CARD PRESENT (VIOLET)
5-12 VDC (RED)
GROUND (BLACK)
DATA0/DATA (GREEN)
DATA1/CLOCK (WHITE)
HOLD (BLUE)
1.68
Проектирование. Монтаж. Продажа. - http://vskd.ru

____________________________________________________________________________________________
HID Corporation 9292 Jeronimo Road Irvine, CA 92618-1905 USA TEL (949) 598-1600 (800) 237-7769 FAX (949) 598-1690 Web
page, E-mail - www.prox.com ThinLine II Reader Installation Manual 5395-901 REV B 4of 5
Wire Connections
12345678910
+DC Ground Data0/
Data Data1/
Clock Shield
Ground Green
LED Red
LED Beeper Hold Card
Present
Red Black Green White Drain Orange Brown Yellow Blue ---
+DC, Ground, Shield Ground, Data0 and Data1 are required for Wiegand Operation
+DC, Ground, Shield Ground, Data, Clock, and Card Present are required for Clock and Data Operation.
All others (Green LED, Red LED, Beeper and Hold are optional.
Notes: 1) When using a separate power supply for the ThinLineII, the power supply and Host should have
a common ground (voltage reference). 2) If the Host is controlling the beeper, Hold, or the LEDs are
configured for the dual LED mode, additional conductors will be required. The recommended cables are
Alpha 1295C, 1296C, 1297C, 1298C and 1299C that are five, six, seven, eight and nine conductors
respectively. Larger wire gauges are acceptable. The wire is to be stranded with an overall shield, either
foil or braided. 3) The Cable shield should be connected to the Shield Ground on Reader TB1- 5, and left
floating at the Panel or power supply end of the cable. This configuration is the best for shielding the
reader cable from external interference and reducing the likelihood of the Reader causing interference.
Product Configuration/Ordering Options
539X BXXXX - XXXX YCustomer Custom Artwork or Firmware Number - 1 through 9, A
through Z
Customer Custom Number
Configuration Options - (00 standard)
Standard Hardware Options - P = Pigtail, T = Terminal strip,
*Other
Color - B = Beige, W = White, K = Black
Current Revision Letter - changes for upgrades
Model Number 5395 = ThinLine II Wiegand,
5368 = ThinLine II Clock and Data
ØStandard Wiegand Part Number = 5395WN00 is a ThinLine II, White, Potted and 10
conductor, 15” Pigtail.
ØStandard Clock and Data Part Number = 5398WN00 is a ThinLine II, White, Potted and 10
conductor, 15” Pigtail.
Product Specifications
Read Distance
ØOverall Operating Limits (12VDC - minimum) 4.00 inches (10.2 cm)
ØNon-Metallic Mounting (12VDC - typical) 5.0 inches (12.7 cm)
ØMounted on Metal (12VDC - typical) 5.0 inches (12.7 cm)
ØOverall Operating Limits (5VDC - minimum) 2.5 inches (6.3 cm)
ØNon-Metallic Mounting (5VDC - typical) 3.0 inches (7.6 cm)
ØMounted on Metal (5VDC - typical) 3.0 inches (7.6 cm)
Проектирование. Монтаж. Продажа. - http://vskd.ru

____________________________________________________________________________________________
HID Corporation 9292 Jeronimo Road Irvine, CA 92618-1905 USA TEL (949) 598-1600 (800) 237-7769 FAX (949) 598-1690 Web
page, E-mail - www.prox.com ThinLine II Reader Installation Manual 5395-901 REV B 5of 5
Regulatory Requirements (applied for)
ØUnderwriters Laboratories listing under UL 294 Access Control Unit Accessory
ØUK and Germany National Type Approvals
ØCE Mark - See letter of Conformance
ØFCC certification
Environmental Characteristics
ØDesigned for listing under UL 294 “Standard for Access Control System Units”
ØIndoor and Outdoor UL Listed
ØOperating Temperature Range -30oC to 65oC (-22oF to 150oF)
ØStorage Temperature Range -40oC to 85oC (-40oF to 185oF)
ØOperating Humidity Range 5% to 95% non-condensing
ØOperating Vibration Limit .04 g2/Hz 20-2000Hz
ØOperating Shock Limit 30g, 11mS, Half Sine
ØPotting Material UL Recognized Filled Polyurethane
ØEnclosure Material UL Recognized Lexan Polycarbonate
ØPotted Weight 5.6oz (157gms)
Power Requirements
ØPower supply Linear type recommended
ØOperating Voltage Range 4.75VDC -16.0VDC
ØAbsolute Maximum (DC+ non-operating) 18.0VDC
ØMaximum Average Current 5V/12V 40mA/50mA
ØTransient Protection (all terminals) 8,000 volts
ØReverse Voltage Protection YES
ØInput Voltage (maximum data-0/1 lines) 16.0VDC
ØInput Voltage (maximum interface lines) 16.0VDC
Operating Parameters
ØExcitation Frequency 125KHz
ØDuty Cycle (alternate power level rate) 20% @ 60mS period
ØRead and Report Speed (26 bit Wiegand Card) 175mS
ØMaximum Cable Distance to Host 500 feet (152 meters)
ØLED Type Bi-colored Red/Green
ØLED Operation (host control of red/green) <.5V on LED control line
ØBeeper Operation (host control) <.5V on beeper line
ØLED Control (default) internal/single
ØBeeper Control (default) beeper enabled
ØAnti-Pass Back Delay (default) 1 second
ØWiegand Data Pulse Widths (default) 40uS
ØWiegand Data Interval (default) 2mS
ØClock Bit time (default) 1.5mS
ØClock/Strobe Pulse width (default) 500uS
ØCard Present Valid (default) Data Frame plus 1mS
NOTES: THE ABOVE ARE RECOMMENDED INSTALLATION PROCEDURES. ALL LOCAL,
STATE AND NATIONAL ELECTRICAL CODES TAKE PRECEDENCE.
Проектирование. Монтаж. Продажа. - http://vskd.ru
Popular Card Reader manuals by other brands

Kingston Technology
Kingston Technology MobileLite Wireless user manual

ACS
ACS ACR1281U-C1 Dualboost 2 Product information

Sony
Sony Felica RC-S360/S specification

Quatech
Quatech 940-0161-100 user manual

TouchStar
TouchStar PP1-RX2 Installation and maintenance guide

Infinite Peripherals
Infinite Peripherals INFINEA BLUEPAD quick start guide