HID R10-H User manual

Installation Guide
pivCLASS®
Reader
GOVERNMENT SOLUTIONS for Physical Access
PLT-01134 A.2
R10-H, RP10-H, R15-H, RP15-H,
R30-H, RP30-H, R40-H, RP40-H,
RK40-H, RPK40-H, RKCL40-P,
RPKCL40-P, RKCLB40-P,
RPKCLB40-P

INSTALLATION GUIDE2© 2012 - 2014 HID Global Corporation/ASSA ABLOY AB. All rights reserved.
PLT-01134 A.2
pivCLASS R10-H, RP10-H, R15-H, RP15-H, R30-H, RP30-H, R40-H, RP40-H, RK40-H,
RPK40-H, RKCL40-P, RPKCL40-P, RKCLB40-P, RPKCLB40-P
Parts List
Specifications
pivCLASS Protocol
UL Reference Number Deciphering
x1Reader Colors: K = Black, G = Gray
x2 Wiring: N = Pigtail, T = Terminal
x3 Communications: N = No Module,
R = RS-485 (OSDP)
1 - Reader and base plate assembly
1 - Installation guide
2 - Terminal connector - terminal readers only
RKCL40, RPKCL40, RKCLB40, and RPKCLB40
4 - M3.5 mm x 12 mm phillips machine screw
4 - #6-32 x .375” phillips self-tapping machine screw
4 - #6 x 1.5” phillips sheet metal screw
3 - #6-32 x .4375” spanner security screw, anti-tamper (Black)
3 - #6-32 x .4375 phillips security screw (Black)
1 - Mounting Gasket
R10, RP10, R15, RP15, R30, RP30, R40, RK40, RP40, and RPK40
2 - M3.5 mm x 12 mm phillips machine screw
3 - #6-32 x .375” phillips self-tapping machine screw
2 - #6 x 1.5” phillips sheet metal screw
1 - #6-32 x .375” spanner security screw, anti-tamper
1 - Mounting gasket - (Optional)
Recommended
• Cable, 6 conductor, 22 or 24 AWG [65 mm or 51 mm]
(Belden 3108A or equivalent) - RS-485 + power
• Cable, 6 to 9 conductor, 22 or 24 AWG [65 mm or 51 mm]
(Alpha 1296C or equivalent) - Wiegand + power
• DC power supply
• Metal or plastic double-gang junction box - RPKCL40 / RPKCL40 /
RKCLB40 / RPKCLB40
• Metal or plastic single-gang junction box - R10 / RP10 / R15 / RP15 / R30 /
RP30 / R40 / RP40 / RK40 / RPK40
• Reader spacer when using metal junction boxes - see HID HTOG.
• Security tool (for spanner security screw, anti-tamper) HID 04-0001-03
PRODUCT BASE PART NUMBER INPUT VOLTAGE (VDC)
CURRENT
OPERATING TEMPERATURE CABLE LENGTH UL REF NUMBER
Standby
AVG1
Maximum
AVG2PEAK3
R10-H 900NHR
12VDC
60mA
100mA
200mA
-30° to 150° F
(-35° to 65° C)
RS-485 = 500 ft - 22 AWG
(152 m)
300 ft - 24 AWG
(91 m)
R10Ex1x2x3
RP10-H 900PHR 75mA RP10Ex1x2x3
R15-H 910NHR 60mA R15Ex1x2x3
RP15-H 910PHR 75mA RP15Ex1x2x3
R30-H 930PHR 65mA
110mA
R30Ex1x2x3
RP30-H 930PHR 85mA RP30Ex1x2x3
R40-H 920NHR 65mA R40Ex1x2x3
RP40-H 920PHR 85mA RP40Ex1x2x3
RK40-H 921NHR 85mA
125mA 220mA
RK40Ex1x2x3
RPK40-H 921PHR 95mA RPK40Ex1x2x3
RKCL40-P 923NPR 150mA 185mA 250mA
-4° to 149° F
(-20° to 65° C)
RKCL40Ex1x2x3
RPKCL40-P 923PPR RPKCL40Ex1x2x3
RKCLB40-P 924NPR
165mA 215mA 275mA
RKCLB40Ex1x2x3
RPKCLB40-P 924PPR RPKCLB40Ex1x2x3
PRODUCT BASE PART NUMBER INPUT VOLTAGE (VDC)
CURRENT1
OPERATING TEMPERATURE CABLE LENGTH5UL REF NUMBER
Standby
AVG2
Maximum
AVG3PEAK4
R10-H 900N
5-16VDC
12VDC for RS-485
60mA
100mA
200mA
-30° to 150° F
(-35° to 65° C)
Communication Lines
Wiegand = 500 ft - 22 AWG
(152 m)
300 ft - 24 AWG
(91 m)
RS-485 = 4000 ft - 24 AWG
(1,219 m)
R10Ex1x2x3
RP10-H 900P 75mA RP10Ex1x2x3
R15-H 910N 60mA R15Ex1x2x3
RP15-H 910P 75mA RP15Ex1x2x3
R30-H 930N 65mA
110mA
R30Ex1x2x3
RP30-H 930P 85mA RP30Ex1x2x3
R40-H 920N 65mA R40Ex1x2x3
RP40-H 920P 85mA RP40Ex1x2x3
RK40-H 921N 85mA
125mA 220mA
RK40Ex1x2x3
RPK40-H 921P 95mA RPK40Ex1x2x3
RKCL40-P 923N
12VDC
150mA 185mA 250mA
-4° to 149° F
(-20° to 65° C)
Wiegand and RS-485
500 ft - 22 AWG (152 m)
300 ft - 24 AWG (91 m)
RKCL40Ex1x2x3
RPKCL40-P 923P RPKCL40Ex1x2x3
RKCLB40-P 924N
165mA 215mA 275mA
RKCLB40Ex1x2x3
RPKCLB40-P 924P RPKCLB40Ex1x2x3
Wiegand and OSDP Protocol
1 StandbyAVG-RMScurrentdrawwithoutacardintheRFeld.
2Maximum AVG - RMS current draw during continuous PIV card reads. Not evaluated by UL.
3Peak - highest instantaneous current draw during RF communication.
UL Reference Number Deciphering
x1Reader Colors: K = Black, G = Gray
x2 Wiring: N = Pigtail, T = Terminal
x3 Communications: N = No Module, R = RS-485
1 Communication protocols other than Wiegand or Clock
& Data require an additional hardware module which
increases current by 30 mA.
2 StandbyAVG-RMScurrentdrawwithoutacardintheRFeld.
3 Maximum AVG - RMS current draw during continuous PIV card reads. Not
evaluated by UL.
4 Peak - highest instantaneous current draw during RF communication.
5 Wiegand Cable Lengths:
100 ft (30.5 m) 22 AWG @ 5 - 6.4VDC
500 ft (152 m) 22 AWG @ 6.5 - 16VDC

INSTALLATION GUIDE 3
© 2012 - 2014 HID Global Corporation/ASSA ABLOY AB. All rights reserved.
pivCLASS
PLT-01134 A.2 R10-H, RP10-H, R15-H, RP15-H, R30-H, RP30-H, R40-H, RP40-H,
RPK40-H, RKCL40-P, RPKCL40-P, RKCLB40-P, RPKCLB40-P
Mounting
1Attach Backplate and Mounting Gasket to Junction Box.
Reverse Conguration Flipping the
backplate allows for placing the Contact
reader on left and the Keypad reader on right.
Contactless Models
Contact Models
Mounting holes for US double-gang
electrical boxes.
Junction box not included.
Mounting holes for US single-gang
electrical boxes.
Install gasket for RK40 and RPK40
models.

INSTALLATION GUIDE4© 2012 - 2014 HID Global Corporation/ASSA ABLOY AB. All rights reserved.
PLT-01134 A.2
pivCLASS R10-H, RP10-H, R15-H, RP15-H, R30-H, RP30-H, R40-H, RP40-H, RK40-H,
RPK40-H, RKCL40-P, RPKCL40-P, RKCLB40-P, RPKCLB40-P
Wiring
2
ATTENTION
Observe precautions for handling
ELECTROSTATIC SENSITIVE DEVICES
Pigtail Terminal Description Pigtail Terminal Description
Yellow P1-1 Beeper Input Red / Green P2-7 GPIO1 (RS232-T / RS485-FDX/HDX-A) See Note 1
Orange P1-2 LED Input (GRN) Tan P2-6 GPIO2 (RS232-R / RS485-FDX/HDX-B) See Note 1
Black P1-3 Ground (RTN) Violet P2-5 Open Collector Output / Tamper See Note 2
Red P1-4 +VDC White P2-4 Wiegand Data 1 / Clock See Note 3
Drain P1-5 Unused Green P2-3 Wiegand Data 0 / Data See Note 3
Brown P1-6 LED Input (RED) Pink P2-2 GPIO3 (RS485-FDX-Z) See Note 1
Blue P1-7 Hold Input Gray P2-1 GPIO4 (RS485-FDX-Y) See Note 1
Notes
1RS-485 applicable for pivCLASS readers.
2Tamper Output - When activated, output synchronizes to ground (default).
3 Dependentuponreaderconguration.SeetheHTOGforWiegandandClock-in-Datacongurations.
P1
P2
Beeper
GRN LED
GND
+VDC
DRAIN
RED
HOLD
GPIO1
GP102
OC/TMPR
DATA1/CLK
DATA2/DATA
GPIO3
GPIO4
Beeper
GRN LED
GND
+VDC
DRAIN
RED
HOLD
GPIO1
GP102
OC/TMPR
DATA1/CLK
DATA2/DATA
GPIO3
GPIO4
Terminal ReaderPigtail Reader
18 in
(0.46 m)
BEEP (YEL)
GRN LED (ORN)
GND (BLK)
+VDC (RED)
DRAIN (BARE)
RED LED (BRN)
HOLD (BLU)
GPIO1(RED/GRN)
GPIO2 (TAN)
OC/TMPR (VIO)
DATA1 (WHT)
DATA2 (GRN)
GPIO3 (PINK)
GPIO4 (GRAY)
(Terminal block and module
position varies)
(Module position varies)
Note: Previous iCLASS readers had
reversed RS-485 wiring ( P2-7 &
P2-6 - A & B). When upgrading to
a pivCLASS reader, ensure proper
connectionsasdenedbelow.

INSTALLATION GUIDE 5
© 2012 - 2014 HID Global Corporation/ASSA ABLOY AB. All rights reserved.
pivCLASS
PLT-01134 A.2 R10-H, RP10-H, R15-H, RP15-H, R30-H, RP30-H, R40-H, RP40-H,
RPK40-H, RKCL40-P, RPKCL40-P, RKCLB40-P, RPKCLB40-P
Attach to Backplate
3
ab
Default: Slide Reader Assembly
towards the right to lock.
ab
Attach Reader Install Security Screw
Contactless Models
Contact Models
Reversed Conguration: Slide Reader
Assembly to the left to lock.
Contact Technical Support for wiring the
reverseconguration.
c

INSTALLATION GUIDE6© 2012 - 2014 HID Global Corporation/ASSA ABLOY AB. All rights reserved.
PLT-01134 A.2
pivCLASS R10-H, RP10-H, R15-H, RP15-H, R30-H, RP30-H, R40-H, RP40-H, RK40-H,
RPK40-H, RKCL40-P, RPKCL40-P, RKCLB40-P, RPKCLB40-P
Power & Testing
Turn on power
Test card
4
Contactless Models
Contact Models
Turn on power
Test card

INSTALLATION GUIDE 7
© 2012 - 2014 HID Global Corporation/ASSA ABLOY AB. All rights reserved.
pivCLASS
PLT-01134 A.2 R10-H, RP10-H, R15-H, RP15-H, R30-H, RP30-H, R40-H, RP40-H,
RPK40-H, RKCL40-P, RPKCL40-P, RKCLB40-P, RPKCLB40-P
Intentionally Blank

HID Global
North America: +1 949 732 2000
Toll Free: 1 800 237 7769
Europe, Middle East, Africa: +49 6123 791 0
Asia Pacific: +852 3160 9800
Latin America: +52 477 779 1492
hidglobal.com
support.hidglobal.com
© 2012 - 2014 HID Global Corporation/ASSA ABLOY AB. All rights reserved.
Check reader label for current regulatory approvals.
UL
Connect only to a Listed Access Control / Burglary power-limited power supply. These readers are intended to be used with listed (UL294) control equipment.
RKCLB40-P and RPKCLB40-P readers are suitable for indoor use. R10-H, RP10-H, R15-H, RP15-H, R30-H, RP30-H, R40-H, RP40-H, RK40-H, RPK40-H, RKCL40-P and
RPKCL40-P are suitable for outdoor use.
Evaluated for use over Wiegand and RS-485 communications.
Evaluated for use with the M2000 pivCLASS Authentication Module as well as Standard Wiegand and OSDP panels.
FCC Certification
CAUTION: Any changes or modications to this device not explicitly approved by manufacturer could void your authority to operate this equipment.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation.
HID, HID Global and pivCLASS are the trademarks or registered trademarks of HID
Global Corporation, or its licensors, in the U.S. and other countries.
PLT-01334 A.1
Patent Pending
Equipment
8T29
ACC Control READER
General Signaling
Equipment
This manual suits for next models
13
Table of contents
Other HID Gateway manuals
Popular Gateway manuals by other brands

SST Automation
SST Automation GT200-MT-DN user manual

HMS
HMS Anybus Modbus to KNX Gateway user manual

Cisco
Cisco VG248 - Gateway Software configuration guide

Eedomus
Eedomus eedomus+ Quick installation guide

ZyXEL Communications
ZyXEL Communications P-662HW-D - V3.40 Support notes

BESTip
BESTip ATA 10D user manual

Wieland
Wieland gesis KNX FLEX-ENO32B installation instructions

Cisco
Cisco SPA122 ATA Quick reference guide

Spectra
Spectra BlackPearl Nearline user guide

ZyXEL Communications
ZyXEL Communications ZyXEL ZyWALL 35 user guide

Patton electronics
Patton electronics SmartNode 4554 Getting started guide

Arris
Arris SURFboard TG862R user guide