About this Manual
The Manual includes instrucons for using and managing the Product. Pictures, charts, images and all other informaon hereinaer are for descripon and explanaon only. The informaon contained in the Manual is subject to change,
without noce, due to firmware updates or other reasons. Please find the latest version of this Manual at the Hikvision website (hps://www.hikvision.com/).
Please use this Manual with the guidance and assistance of professionals trained in supporng the Product.
and other Hikvision's trademarks and logos are the properes of Hikvision in various jurisdicons. Other trademarks and logos menoned are the properes of their respecve owners.
Disclaimer
TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, THIS MANUAL AND THE PRODUCT DESCRIBED, WITH ITS HARDWARE, SOFTWARE AND FIRMWARE, ARE PROVIDED “AS IS” AND “WITH ALL FAULTS AND ERRORS”. HIKVISION MAKES
NO WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION, MERCHANTABILITY, SATISFACTORY QUALITY, OR FITNESS FOR A PARTICULAR PURPOSE. THE USE OF THE PRODUCT BY YOU IS AT YOUR OWN RISK. IN NO EVENT WILL
HIKVISION BE LIABLE TO YOU FOR ANY SPECIAL, CONSEQUENTIAL, INCIDENTAL, OR INDIRECT DAMAGES, INCLUDING, AMONG OTHERS, DAMAGES FOR LOSS OF BUSINESS PROFITS, BUSINESS INTERRUPTION, OR LOSS OF DATA, CORRUPTION OF
SYSTEMS, OR LOSS OF DOCUMENTATION, WHETHER BASED ON BREACH OF CONTRACT, TORT (INCLUDING NEGLIGENCE), PRODUCT LIABILITY, OR OTHERWISE, IN CONNECTION WITH THE USE OF THE PRODUCT, EVEN IF HIKVISION HAS BEEN
ADVISED OF THE POSSIBILITY OF SUCH DAMAGES OR LOSS.
YOU ACKNOWLEDGE THAT THE NATURE OF INTERNET PROVIDES FOR INHERENT SECURITY RISKS, AND HIKVISION SHALL NOT TAKE ANY RESPONSIBILITIES FOR ABNORMAL OPERATION, PRIVACY LEAKAGE OR OTHER DAMAGES RESULTING FROM
CYBER-ATTACK, HACKER ATTACK, VIRUS INSPECTION, OR OTHER INTERNET SECURITY RISKS; HOWEVER, HIKVISION WILL PROVIDE TIMELY TECHNICAL SUPPORT IF REQUIRED.
YOU AGREE TO USE THIS PRODUCT IN COMPLIANCE WITH ALL APPLICABLE LAWS, AND YOU ARE SOLELY RESPONSIBLE FOR ENSURING THAT YOUR USE CONFORMS TO THE APPLICABLE LAW. ESPECIALLY, YOU ARE RESPONSIBLE, FOR USING THIS
PRODUCT IN A MANNER THAT DOES NOT INFRINGE ON THE RIGHTS OF THIRD PARTIES, INCLUDING WITHOUT LIMITATION, RIGHTS OF PUBLICITY, INTELLECTUAL PROPERTY RIGHTS, OR DATA PROTECTION AND OTHER PRIVACY RIGHTS. YOU
SHALL NOT USE THIS PRODUCT FOR ANY PROHIBITED END-USES, INCLUDING THE DEVELOPMENT OR PRODUCTION OF WEAPONS OF MASS DESTRUCTION, THE DEVELOPMENT OR PRODUCTION OF CHEMICAL OR BIOLOGICAL WEAPONS, ANY
ACTIVITIES IN THE CONTEXT RELATED TO ANY NUCLEAR EXPLOSIVE OR UNSAFE NUCLEAR FUEL-CYCLE, OR IN SUPPORT OF HUMAN RIGHTS ABUSES.
IN THE EVENT OF ANY CONFLICTS BETWEEN THIS MANUAL AND THE APPLICABLE LAW, THE LATER PREVAILS.
1Introducon
Appearance
2
3Indicaon
This product and - if applicable - the supplied accessories too are
marked with "CE" and comply therefore with the applicable harmonized
European standards listed under the EMC Direcve 2014/30/EU, the RE
Direcve 2014/53/EU, the RoHS Direcve 2011/65/EU.
replacement of a baery with an incorrect type that can defeat a safeguard (for example, in the case of some lithium
baery types);
– disposal of a baery into fire or a hot oven, or mechanically crushing or cung of a baery, that can result in an
explosion;
– leaving a baery in an extremely high temperature surrounding environment that can
result in an explosion or the leakage of flammable liquid or gas; and
– a baery subjected to extremely low air pressure that may result in an explosion or the leakage of flammable liquid
or gas
Fault
Fire Alarm
Relay Control
Disarm
Away Arm
Stay Arm
Panic Alarm
Medical Alarm
Armed/Disarmed
Enrollment/Signal Strength
Enrollment
With Fault
LED Indicaon Descripon
Buzzer Descripon
Armed
Disarmed
Arming Failed
Disarming Failed
Operaon completed: Beep twice
Operaon failed: Beep three mes
Solid orange for 3 s and then off
Solid blue for 5 s
Green flashes 2 mes
Blue turns Off
Green turns Off
Tampering Alarm
No Alarm
Event Alarm
Note: Event Alarm Priority > Tampering Alarm Priority
Solid red
Off
Flashing red
OffNo Fault
Signal Strength
Find Me
Power On
Back Light
-If the keypad is not enrolled to the control panel, the back light is off.
-It turns off when there is no key operaon for more than 10 s.
Alarm
Tamper Switch
Power Switch
Serial Port
Solid green for 3 s: Strong
Solid orange for 3 s: Medium
Solid red for 3 s: Weak
Flashing red for 3 s: Disconnected
Flashing red and green: Enrolling
Green flashes 7 mes: Enrolled
Solid green for 1 s: Powered on
Flashing green for 20 s: Operang
-The back light is on by default, you can set the On/Off schedule on
the
web client of the control panel. Refer to the user manual of control
2012/19/EU (WEEE direcve): Products marked with this symbol
cannot be disposed of as unsorted municipal waste in the European
Union. For proper recycling, return this product to your local supplier
upon the purchase of equivalent new equipment, or dispose of it at
designated collecon points. For more informaon see:
www.recyclethis.info
2006/66/EC (baery direcve): This product contains a baery that cannot be disposed of as unsorted municipal
waste in the European Union. See the product documentaon for specific baery informaon. The baery is marked
with this symbol, which may include leering to indicate cadmium (Cd), lead (Pb), or mercury (Hg). For proper
recycling, return the baery to your supplier or to a designated collecon point. For more informaon see:www.recy-
clethis.info
1
CAUTION
RISK OF EXPLOSION IF BATTERY
IS REPLACED BY AN INCORRECT
TYPE.
REPLACEMENT OF A BATTERY
WITH AN INCORRECT TYPE THAT
CAN DEFEAT A SAFEGUARD.
CAUTION
CHEMICAL BURNING DANGER
DO NOT SWALLOW THE
BATTERY
KEEP NEW AND USED
BATTERIES AWAY FROM THE
CHILDREN.
IF YOU THINK BATTERIES MIGHT
HAVE BEEN SWALLOWED OR
PLACED INSIDE ANY PART OF
THE BODY, SEEK IMMEDIATE
MEDICAL ATTENTION.
CAUTION
DISPOSE OF USED BATTERIES
ACCORDING TO THE INSTRUC-
TIONS AND LOCAL REGULATION.
EN 50131-1:2006+A2:2017
EN 50131-3:2009
EN 50131-5-3:2017
Security Grade(SG) 2
Environmental Class(EC) II

4Enrollment
5Installaon
2. Aach the front panel onto the rear panel.
Note: The addional force shall be equal to three mes the weight of the equipment but not less than 50N. The equipment
and its associated mounng means shall remain secure during the installaon. Aer the installaon, the equipment, including
any associated mounng plate, shall not be damaged.
1. Secure the rear panel on the wall with
four supplied screws.
3. Tighten the screw on the
boom to complete the
Enroll the Peripheral Locally
Enroll the Peripheral with QR Code or Serial No.
1. In the APP, tap the "Enrollment Mode" buon on the control panel page to make the control panel enter the enroll-
ment status.
2. Push the power switch of the peripheral to on, and it will be automacally enrolled to the control panel.
1. In the APP, tap the icon "+"and scan the QR code or enter the serial No. on the peripheral.
2. Push the power switch of the peripheral to on, and it will be automacally enrolled to the control panel.
1. Remove the screw on the boom of the keypad.
2. Disassemble the keypad and remove the rear panel.
3. Power on the security control panel.
4. Log in the Hik-Connect APP and tap the icon "+" . Scan the QR code or input the control panel serial No. to add the
control panel.
5. Enroll the peripheral locally, with OR code, or with serial No..
Note: for re-enrollment, you need to hold the tamper buon while powering the peripheral on simultaneously.
Remove the screw on the boom of the keypad.
Disassemble the keypad and remove the rear panel. Scan the QR code on the rear panel of the keypad. Push the power switch to ON.
Check signal strength and select installaon place
Enter the signal checking mode by operang on the control panel.
Signal LED turns green for 3 s: Strong.
Signal LED turns orange for 3 s: Medium.
Signal LED turns red for 3 s: Weak.
Signal LED flashes red for 3 s: Disconnected.
2
CAUTION
IF THE BATTERY COMPARTMENT
DOES NOT CLOSE SECURETLY,
STOP USING THE PRODUCT AND
KEEP IT AWAY FROM CHILDREN.

7Specificaon
Command
6
The keypad command is shown as follows.
The keypad technical specificaon is shown as follows.
EventsCodesNotes
Away arming for all areas:
User password +Away
Away arming for specified area:
User password +# +Area
No.(1,2.3.4.5.6.7.8.9.010.011.012....)
+away
-The keypad does not display area No. greater than 9.
-If the area No. is greater than 9, enter "0XX"for the No.."0"indicates
tens digits, and "XX"indicates the actual area No.
-If the selected area is not related to the keypad,the back light of “0” will
Stay arming for all areas:
User password +Stay
Stay arming for specified area:
User password +# +Area
No.(1,2.3.4.5.6.7.8.9.010.011.012....)
+Stay
-The keypad does not display area No. greater than 9.
-If the area No. is greater than 9, enter "0XX"for the No.."0"indicates
tens digits, and "XX"indicates the actual area No.
-If the selected area is not related to the keypad,the back light of “0” will
flashes three mes.
Disarming for all areas:
User password +Disarm
Disarming for specified area:
User password +# +Area
No.(1,2.3.4.5.6.7.8.9.010.011.012....)
+Disarm
-The keypad does not display area No. greater than 9.
-If the area No. is greater than 9, enter "0XX"for the No.."0"indicates
tens digits, and "XX"indicates the actual area No.
-If the selected area is not related to the keypad,the back light of “0” will
flashes three mes.
Clear alarm User Password+Hold Disarm
Fire Hold "1/Fire Alarm" for 3 s The Buzzer will beepthree mes for failure operaon.
PA Hold "2/Panic Alarm" for 3 s The Buzzer will beepthree mes for failure operaon.
Medical Hold "3/Medical"for 3 s The Buzzer will beepthree mes for failure operaon.
Duress (Duress Code)+disarmYou can set the duress code on the web client ofthe control panel. Refer to
the user manual ofcontrol panel for details.
Output
User Password+Output+relay
No.(1,2.3.4.5.6.7.8.9.010.011.012....)+
#
-If the relay No. is greater than 9, enter "0XX" for the No.."0"indicates tens
digits, and "XX"indicates the actual relay No.
-A successful command execuon implement an operaon "Off" or "On".
Away arm
Stay arm
Disarm
3
Speed 42Kbps
Frequency 868.0MHz
Method 2GFSK
Distance 1200m(open area)
Transmion power 13 dbm
Tamper switch 1, front and rear panel tamper-proof
Wireless module For wireless communicaon
Power switch Power on/off
Buzzer 1
Indicator
4: fault (orange), enrollment/signal (red/green),
arming(red/green/blue), and alarm(red)
Backlight white
Number key 10:0 to 9
Funcon key
5: *, #, stay arming, away arming, disarming, and
Humidity 10
%
to 90
%
Temperature ﹣10℃to +55℃
Color White/Black
Dimension(W xH xD)140 x86x22 mm,
Installaon Installaon Screw mounng
Power Supply Power Supply
1.5VDC, four AA baterries, standby me more
than two years
Weight
Weight without
baeries
151 g, and 23 g each baery
Operaon
Environment
Appearance
Wireless Keypad
RF
Interface
Display
Key

8Operaon
Keypad Status
Operaon Interval
Keypad Lock
Sleep Status
Working Status
Enrollment Status
Free Status
The keypad will enter the sleep status
while meeng the following condions:
No RF data transmission
No key operaon for more than 10 s
No keypad tampering alarm
No polling
No beeping
No LED indicaon
The keypad will enter the sleep status while
meeng the following condions:
RF data transmission
key operaon
keypad tampering alarm
polling
Beeping
LED indicaon
While the keypad is enrolled to a control
panel, it enters the enrollment status.
Only if the keypad is enrolled, the key
operaon and status indicaon take
effects.
There is no area related to the keypad.
The key and back light do not works.
The interval between the operaons (successful or failed) should be more than 3 s.
The connuous operaon of the key should be in 10 s.
The Key pad will be locked aer 3 to 5 failure authencaon aempts.You can set the lock me on the web client of
the control panel
Arming Process
Pre-delay
Indicaon:
The arming LED turns flashing blue
Fault Checking
Indicaon:
The arming LED turns flashing orange
Exit Delay
Indicaon:
Arming LED turns flashing blue, and the buzzer indicates exit delay.
Arm Directly
Press the Arm key to arm the device.
Indicaon:
Armed: arming LED solid blue for 5 s. Buzzer beeps twice.
Arming failed: Buzzer beeps three me.
Disarm
Press the Disarm key to disarm the device.
Indicaon:
Armed: Buzzer beeps twice.
Arming failed: Buzzer beeps three me.
No Instant Operaon
The count down is finished.
Indicaon:
Armed: arming LED solid blue for 5 s. Buzzer beeps twice.
Arming failed: Buzzer beeps three me.
Confirm the operaon by press the Arm key
4
Other HIK VISION Keypad manuals

HIK VISION
HIK VISION DS-KDM9403-FKP User manual

HIK VISION
HIK VISION DS-PK1-LRT-HWB User manual

HIK VISION
HIK VISION Pyronix MX-SERIES User manual

HIK VISION
HIK VISION DS-PK1-LRT-HWE User manual

HIK VISION
HIK VISION DS-PK1-E-WE User manual

HIK VISION
HIK VISION DS-PK00-LCD series User manual

HIK VISION
HIK VISION DS-PK1-E-WB User manual

HIK VISION
HIK VISION DS-PK-L Series User manual

HIK VISION
HIK VISION DS-PK1-LT-WE Series User manual

HIK VISION
HIK VISION DS-PK1-E-WB User manual