Hirschmann OpEdge-8D User manual

Installation OpEdge-8D
Release
01
10/2022
Technical support
https://hirschmann-support.belden.com
User Manual
Installation
Industrial Edge Gateway
OpEdge-8D

2022-10-07 Installation OpEdge-8D
Release
01
10/2022
The naming of copyrighted trademarks in this manual, even when not specially indicated, should
not be taken to mean that these names may be considered as free in the sense of the trademark
and tradename protection law and hence that they may be freely used by anyone.
© 2022 Hirschmann Automation and Control GmbH
Manuals and software are protected by copyright. All rights reserved. The copying, reproduction,
translation, conversion into any electronic medium or machine scannable form is not permitted,
either in whole or in part. An exception is the preparation of a backup copy of the software for
your own use.
The performance features described here are binding only if they have been expressly agreed
when the contract was made. This document was produced by Hirschmann Automation and
Control GmbH according to the best of the company's knowledge. Hirschmann reserves the right
to change the contents of this document without prior notice. Hirschmann can give no guarantee
in respect of the correctness or accuracy of the information in this document.
Hirschmann can accept no responsibility for damages, resulting from the use of the network
components or the associated operating software. In addition, we refer to the conditions of use
specified in the license contract.
You can get the latest version of this manual on the Internet at:
https://www.doc.hirschmann.com
Hirschmann Automation and Control GmbH
Stuttgarter Str. 45-51
72654 Neckartenzlingen
Germany

Installation OpEdge-8D
Release
01
10/2022 3
Contents
Important information 5
Safety instructions 7
About this manual 13
Key 14
1 Description 15
1.1 General device description 15
1.2 Device views 16
1.2.1 Front view 16
1.2.2 Right side view 17
1.2.3 Left side view 18
1.3 Power supply 18
1.4 Ethernet ports 18
1.4.1 10/100/1000 Mbit/s twisted pair port 19
1.4.2 1000 Mbit/s F/O port 19
1.4.3 Pin assignments 19
1.5 Display elements 20
1.5.1 Device status 20
1.5.2 Port status 20
1.6 Management interfaces 21
1.6.1 DB9 port 21
1.6.2 USB interface 21
1.7 Input/output interfaces 22
1.7.1 Signal contact 22
2 Installation 23
2.1 Checking the package contents 23
2.2 Installing and grounding the device 23
2.2.1 Installing the device onto the DIN rail 23
2.2.2 Grounding the device 24
2.3 Installing an SFP transceiver (optional) 25

4Installation OpEdge-8D
Release
01
10/2022
2.4 Connecting the terminal blocks 25
2.4.1 Connecting the power supply and signal lines 26
2.5 Operating the device 27
2.6 Connecting data cables 27
2.6.1 Twisted Pair ports 27
2.6.2 1000 Mbit/s F/O port (optional) 28
2.7 Filling out the inscription label 28
2.8 Making basic settings 28
2.8.1 First Login (Password) 28
3 Monitoring the ambient air temperature 30
4 Maintenance and service 31
5Disassembly 32
5.1 Removing the device 32
5.2 Removing an SFP transceiver (optional) 33
6 Technical data 34
6.1 General technical data 34
6.2 Signal contact 34
6.3 Power consumption/power output 35
6.4 Dimension drawings 35
6.5 EMC and immunity 36
6.6 Network range 37
7 Scope of delivery 40
8 Accessories 41
9 Underlying technical standards 42
A Further support 43

Installation OpEdge-8D
Release
01
10/2022 5
Important information
Note: Read these instructions carefully, and familiarize yourself with the
device before trying to install, operate, or maintain it. The following notes may
appear throughout this documentation or on the device. These notes warn of
potential hazards or call attention to information that clarifies or simplifies a
procedure.
Symbol explanation
This is a general warning symbol. This symbol alerts you to
potential personal injury hazards. Observe all safety notes that
follow this symbol to avoid possible injury or death.
If this symbol is displayed in addition to a safety instruction of the
type “Danger” or “Warning”, it means that there is a danger of
electric shock and failure to observe the instructions will
inevitably result in injury.
This symbol indicates the danger of hot surfaces on the device.
In connection with safety instructions, non-observance of the
instructions will inevitably result in injuries.
DANGER
DANGER draws attention to an immediately dangerous situation, which will
inevitably result in a serious or fatal accident if not observed.
WARNING
WARNING indicates a potentially hazardous situation which, if not avoided,
could result in death or serious injury.
CAUTION
CAUTION indicates a possible danger which, if not avoided, may result in
minor injuries.

6Installation OpEdge-8D
Release
01
10/2022
NOTICE
NOTICE provides information about procedures that do not involve the risk
of injury.

Installation OpEdge-8D
Release
01
10/2022 7
Safety instructions
General safety instructions
You operate this device with electricity. Improper usage of the device
entails the risk of physical injury or significant property damage. The
proper and safe operation of this device depends on proper handling
during transportation, proper storage and installation, and careful
operation and maintenance procedures.
Before connecting any cable, read this document, and the safety
instructions and warnings.
Operate the device with undamaged components exclusively.
The device is free of any service components. In case of a damaged
or malfunctioning the device, turn off the supply voltage and return the
device to Hirschmann for inspection.
Certified usage
Use the product only for the application cases described in the
Hirschmann product information, including this manual.
Operate the product only according to the technical specifications.
See “Technical data” on page 34.
Connect to the product only components suitable for the requirements
of the specific application case.
Installation site requirements
Install the device in a fire enclosure according to EN 62368-1.
Install this device only in a switch cabinet or in an operating site with
restricted access, to which maintenance staff have exclusive access.
WARNING
UNCONTROLLED MACHINE ACTIONS
To avoid uncontrolled machine actions caused by data loss, configure all
the data transmission devices individually.
Before you start any machine which is controlled via data transmission, be
sure to complete the configuration of all data transmission devices.
Failure to follow these instructions can result in death, serious injury,
or equipment damage.

8Installation OpEdge-8D
Release
01
10/2022
Strain relief
Note: If the strain relief is insufficient, there is a potential risk of torsion,
contact problems and creeping interruptions.
Relieve the connection points of cables and lines from mechanical
stress.
Design strain reliefs in such a way that they help prevent any
mechanical damage to cables, wires or conductors caused by external
influences or their own weight.
To help prevent damage to device connections, connectors and
cables, follow the instructions for proper installation in accordance with
DIN VDE 0100-520:2013-06, sections 522.6, 522.7 and 522.13.
Device casing
Only technicians authorized by the manufacturer are permitted to open
the casing.
Never insert pointed objects (narrow screwdrivers, wires, etc.) into the
device or into the connection terminals for electric conductors. Do not
touch the connection terminals.
Keep the ventilation slits free to ensure good air circulation.
Install the device in the vertical position.
At ambient temperatures > +60 °C (+140 °F):
The surfaces of the device housing may become hot. Avoid touching
the device while it is operating.
Qualification requirements for personnel
Only allow qualified personnel to work on the device.
Qualified personnel have the following characteristics:
Qualified personnel are properly trained. Training as well as practical
knowledge and experience make up their qualifications. This is the
prerequisite for grounding and labeling circuits, devices, and systems
in accordance with current standards in safety technology.
Qualified personnel are aware of the dangers that exist in their work.
Qualified personnel are familiar with appropriate measures against
these hazards in order to reduce the risk for themselves and others.
Qualified personnel receive training on a regular basis.
National and international safety regulations
Verify that the electrical installation meets local or nationally applicable
safety regulations.

Installation OpEdge-8D
Release
01
10/2022 9
Grounding the device
Grounding the device is by means of a separate ground connection on the
device.
Ground the device before connecting any other cables.
Disconnect the grounding only after disconnecting all other cables.
Shielding ground
The overall shield of a connected shielded twisted pair cable is connected
to the ground connector on the front panel as a conductor.
Beware of possible short circuits when connecting a cable section with
conductive shielding braiding.
Requirements for connecting electrical wires
Before connecting the electrical wires, always verify that the
requirements listed are complied with.
All of the following requirements are complied with:
The electrical wires are voltage-free.
The cables used are permitted for the temperature range of the application case.
The voltage connected complies with the requirements for a safety extra-low voltage
(SELV) according to IEC 60950-1 or ES1 according to IEC/EN 62368-1.
Table 1: General requirements for connecting electrical wires
All of the following requirements are complied with:
The voltage connected complies with the requirements for a safety extra-low voltage
(SELV) according to IEC 60950-1 or ES1 according to IEC/EN 62368-1.
The connected voltage is limited by a current limitation device or a fuse.
Observe the electrical threshold values for the signal contact.
See “Technical data” on page 34.
The cross-section of the ground conductor is the same size as or bigger than the cross-
section of the power supply cables.
Table 2: Requirements for connecting the signal contact
All of the following requirements are complied with:
The supply voltage corresponds to the voltage specified on the type plate of the device.
The power supply complies with the requirements as per NEC Class 2.
The power supply conforms to overvoltage category I or II.
The power supply has an easily accessible disconnecting device (for example, a switch or
a plug). This disconnecting device is clearly identified. So in the case of an emergency, it
is clear which disconnecting device belongs to which power supply cable.
The cross-section of the ground conductor is the same size as or bigger than the cross-
section of the power supply cables.
Relevant for North America:
The power cords are suitable for ambient air temperatures of at least +75 °C (+167 °F). The
power cord wires are made of copper.
Table 3: Requirements for connecting the supply voltage

10 Installation OpEdge-8D
Release
01
10/2022
Supply voltage
The supply voltage is connected to the device casing through protective
elements exclusively.
CE marking
The labeled devices comply with the regulations contained in the following
European directive(s):
2011/65/EU and 2015/863/EU (RoHS)
Directive of the European Parliament and of the Council on the
restriction of the use of certain hazardous substances in electrical and
electronic equipment.
2014/30/EU (EMC)
Directive of the European Parliament and of the Council on the
harmonisation of the laws of the Member States relating to
electromagnetic compatibility.
In accordance with the above-named EU directive(s), the EU conformity
declaration will be at the disposal of the relevant authorities at the
following address:
Hirschmann Automation and Control GmbH
Stuttgarter Str. 45-51
72654 Neckartenzlingen
Germany
You find the EU conformity declaration as PDF file for downloading on the
Internet at: https://www.doc.hirschmann.com/certificates.html
The product can be used in the industrial sector.
Interference immunity: EN 61000-6-2
Emitted interference: EN 55032
Reliability: IEC/EN 62368-1
You find more information on technical standards here:
See “Technical data” on page 34.
The assembly guidelines provided in these instructions must be strictly
adhered to in order to observe the EMC threshold values.
Warning! This is a class A device. This device can cause interference in
living areas, and in this case the operator may be required to take
appropriate measures.

Installation OpEdge-8D
Release
01
10/2022 11
UKCA marking
The labeled devices comply with the following UK regulations:
S.I. 2012 No. 3032
Restriction of the Use of Certain Hazardous Substances in Electrical
and Electronical Equipment Regulations
S.I. 2016 No. 1091
Electromagnetic Compatibility Regulations 2016
The UKCA conformity declaration will be available to the relevant
authorities at the following address:
Belden UK Ltd.
1 The Technology Centre, Station Road
Framlingham, IP13 9EZ, United Kingdom
You find the UKCA conformity declaration as PDF file for downloading on
the Internet at: https://www.doc.hirschmann.com/certificates.html
The product can be used in the industrial sector.
Interference immunity: EN 61000-6-2
Emitted interference: EN 55032
Reliability: IEC/EN 62368-1
You find more information on technical standards here:
See “Technical data” on page 34.
The assembly guidelines provided in these instructions must be strictly
adhered to in order to observe the EMC threshold values.
Warning! This is a class A device. This device can cause interference in
living areas, and in this case the operator may be required to take
appropriate measures.
LED or laser components
LED or LASER components according to IEC 60825-1 (2014):
CLASS 1 LASER PRODUCT
CLASS 1 LED PRODUCT

12 Installation OpEdge-8D
Release
01
10/2022
FCC note
Supplier's Declaration of Conformity
47 CFR § 2.1077 Compliance Information
OpEdge-8D
U.S. Contact Information
Belden – St. Louis
1 N. Brentwood Blvd. 15th Floor
St. Louis, Missouri 63105, United States
Phone: 314.854.8000
This device complies with part 15 of the FCC Rules. Operation is subject
to the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
Note: This equipment has been tested and found to comply with the limits
for a Class A digital device, pursuant to part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential area is likely
to cause harmful interference in which case the user will be required to
correct the interference at his own expense.
Recycling note
After usage, this device must be disposed of properly as electronic waste,
in accordance with the current disposal regulations of your county, state,
and country.

Installation OpEdge-8D
Release
01
10/2022 13
About this manual
The “Installation” user manual contains a device description, safety
instructions, a description of the display, and the other information that you
need to install the device.
The manual is available for download on the Internet: https://
www.doc.hirschmann.com

14 Installation OpEdge-8D
Release
01
10/2022
Key
The symbols used in this manual have the following meanings:
Listing
Work step
Subheading

Installation OpEdge-8D
Release
01
10/2022 15
1 Description
1.1 General device description
The OpEdge-8D devices are designed for the special requirements of
industrial automation. They meet the relevant industry standards, provide
very high operational reliability, even under extreme conditions, and also
long-term reliability and flexibility.
Key Features:
A fanless industrial grade Edge appliance
Flexible LAN: 5 × GE with 1 pair bypass Gen 3 and 2 × SFP
Supports wall mount kit and DIN rail kit
The devices allow you to set up switched and routed industrial Ethernet
networks according to IEEE 802.3.
The devices provide you with a large range of functions, which the manuals
for the operating software inform you about. You will find these manuals in
the form of PDF files for downloading on the Internet on the Hirschmann
product pages (https://www.doc.hirschmann.com).
The Hirschmann network components help you ensure continuous
communication across all levels of the company.

16 Installation OpEdge-8D
Release
01
10/2022
1.2 Device views
1.2.1 Front view
1 LED display element
2 2 × USB interface
3 5 × Gigabit Ethernet ports (RJ45) for 10/100/1000 Mbit/s Twisted pair connections
4 COM port (DB9 port)
5 COM port (DB9 port)
6 2 × SFP ports for 1000 Mbit/s fiber optic connections
1
2
3
4
5
6

Installation OpEdge-8D
Release
01
10/2022 17
1.2.2 Right side view
1 6-pin terminal block connection
2 Grounding screw
1
2

18 Installation OpEdge-8D
Release
01
10/2022
1.2.3 Left side view
1.3 Power supply
A 6-pin, screwable terminal block is available for the redundant supply to the
device.
For further information: See “Connecting the power supply and signal lines”
on page 26.
1.4 Ethernet ports
You can connect end devices and other segments to the device ports using
twisted pair cables or optical fibers (F/O).
You find information on pin assignments for making patch cables here:
See “Pin assignments” on page 19.
1 Reset buttona
a. The reset button has no functionality in the current release.
1

Installation OpEdge-8D
Release
01
10/2022 19
1.4.1 10/100/1000 Mbit/s twisted pair port
This port is an RJ45 socket.
The 10/100/1000 Mbit/s twisted pair port offers you the ability to connect
network components according to the IEEE 802.3 10BASE-T/100BASE-TX/
1000BASE-TX standard.
This port supports:
Autonegotiation
Autopolarity
Autocrossing (if autonegotiation is activated)
1000 Mbit/s half-duplex mode, 1000 Mbit/s full duplex mode
100 Mbit/s half-duplex mode, 100 Mbit/s full duplex mode
10 Mbit/s half-duplex mode, 10 Mbit/s full duplex mode
Delivery state: Autonegotiation activated
The socket housing is electrically connected with the front panel.
1.4.2 1000 Mbit/s F/O port
This port is an SFP slot.
The 1000 Mbit/s F/O port offers you the ability to connect network
components according to the IEEE 802.3 1000BASE-SX/1000BASE-LX
standard.
This port supports:
Full duplex mode
1.4.3 Pin assignments
RJ45 Pin 10/100 Mbit/s 1000 Mbit/s
MDI mode
1 TX+ BI_DA+
2TX−BI_DA−
3 RX+ BI_DB+
4— BI_DC+
5— BI_DC−
6RX−BI_DB−
7— BI_DD+
8— BI_DD−
MDI-X mode
1 RX+ BI_DB+
2RX−BI_DB−
3 TX+ BI_DA+
4— BI_DD+
5— BI_DD−
6TX−BI_DA−
7— BI_DC+
8— BI_DC−
1
2
3
4
5
6
7
8

20 Installation OpEdge-8D
Release
01
10/2022
1.5 Display elements
1.5.1 Device status
1.5.2 Port status
LED Display Color Activity Meaning
POWER Supply voltage — None Supply voltage is too low.
Green Lights up The supply voltage is on.
STA Device status — None Device is powered off.
Green Lights up Device is not reporting any device status
alarms.
Red Lights up Device is reporting a device status alarm.
HDD Hard disk activity — None No data access activity
Yellow Flashing Data access activity
LED Display Color Activity Meaning
1 ... 4
7
Link status
(LED on the left)
— None No link is established.
Yellow Lights up Link has been established.
Flashing The connection is active.
Speed
(LED on the right)
— None Operating as a 10-Mbit/s connection
Green Lights up Operating as a Gigabit connection
Yellow Lights up Operating as a 100-Mbit/s connection
(1000 Mbit/s)
5 ... 6 Link status — None No link is established.
Yellow Lights up Link has been established.
Flashing The connection is active.
COM TX activity
(LED on the left)
— None No data activity
Yellow Lights up Device is transmitting data
RX activity
(LED on the right)
— None No data activity
Yellow Lights up Device is receiving data
POWER
STA
HDD
1
3
5
2
4
76
COM2 COM1