HK Instruments PS Series User manual

Copyright HK Instruments 2018 www.hkinstruments. Installaon version 6.0 2018
INSTALLATION
INSTRUCTIONS
DIFFERENTIAL PRESSURE SWITCHES
PS Series
• READ THESE INSTRUCTIONS CAREFULLY BEFORE
ATTEMPTING TO INSTALL, OPERATE OR SERVICE THIS
DEVICE.
• Failuretoobservesafetyinformaonandcomplywith
instruconscanresultinPERSONALINJURY,DEATHAND/OR
PROPERTY DAMAGE.
• Toavoidelectricalshockordamagetoequipment,disconnect
powerbeforeinstallingorservicinganduseonlywiringwith
insulaonratedforfulldeviceoperangvoltage.
• Toavoidpotenalreand/orexplosiondonotuseinpotenally
ammableorexplosiveatmospheres.
• Retaintheseinstruconsforfuturereference.
• Thisproduct,wheninstalled,willbepartofanengineered
systemwhosespecicaonsandperformancecharacteriscs
arenotdesignedorcontrolledbyHKInstruments.Review
applicaonsandnaonalandlocalcodestoassurethatthe
installaonwillbefunconalandsafe.Useonlyexperiencedand
knowledgeabletechnicianstoinstallthisdevice.
SPECIFICATIONS
Thank you for choosing an HK Instruments PS series dierenal
pressureswitch.ThePSseriesisintendedforuseincommercialen-
vironments.Itisdesignedwitheldselectablesetpointadjustment
tomeetyourapplicaonrequirements.
ThePSseriesdierenalpressureswitchesiscomprisedofPS300
with range from 30...300 Pa, PS500 with range from 30...500
Pa, PS600 with range from 40...600 Pa, PS1500 with range from
100...1500PaandPS4500withrangefrom500...4500Pa.
PSseriesdevicesarecommonlyusedinHVAC/Rsystemsfor:
•fan,blowerandltermonitoring
•pressureandowmonitoring
•valveanddampermonitoring
SPECIFICATIONS
Performance
Accuracy (at applied pressure)
Atlowlimit(Typical):
PS200:±5Pa
PS300:±5Pa
PS500:±5Pa
PS600:±5Pa
PS1500:±20Pa
PS4500:±100Pa
Athighlimit(Typical):
PS200:±20Pa
PS300:±30Pa
PS500:±30Pa
PS600:±50Pa
PS1500:±50Pa
PS4500:±200Pa
Switching dierenal:
PS200:20Pa
PS300:20Pa
PS500:20Pa
PS600:30Pa
PS1500:80Pa
PS4500:250Pa
Overpressure:
Proofpressure:25kPa
Burstpressure:50kPa
Technical Specicaons
Media compability:
Dryairornon-aggressivegases
Measuring units:
Pa
Measurement range:
PS200:20-200Pa
PS300:30-300Pa
PS500:30-500Pa
PS600:40-600Pa
PS1500:100-1500Pa
PS4500:500-4500Pa
Environment:
Operangtemperature:-20...60°C
Storagetemperature:-20...85°C
Humidity:0to95%rH,noncondensing
Physical
Dimensions:
Case:105x73x63mm
Weight:
150g
Mounng:
2each4.3mmscrewholes,onesloed
Materials:
Case:ABS
Cover:PC
Membrane:Silicone
Ductconnectors:ABS
Tubing:PVC
Protecon standard:
IP54
Electrical connecons:
3screwterminals
Wire:12–24AWG(0.2–1.5mm2)
Cable entry:
Strainrelief:M16
Knockout:16mm
Pressure ngs:
Maleø5.0mm
Electrical
Input:
24–250VAC
Output:
NO/NCcircuit
Electrical rang, resisve load:
3A/250VAC(PS200:0.1A/250VAC)
Electrical rang, inducve load:
2A/250VAC(PS200:-)
Conformance
MeetsrequirementsforCEmarking:
RoHSDirecve2011/65/EU
LVDDirecve2014/35/EU
WEEEDirecve2012/19/EU
INTRODUCTION WARNING
APPLICATIONS
COMPANY WITH
MANAGEMENT SYSTEM
CERTIFIED BY DNV GL
= ISO 9001 = ISO 14001 =
RoHS 2
2011/65/EU
Copyright HK Instruments 2018 www.hkinstruments. Installaon version 6.0 2018
INSTALLATION
Figure 1a - Surface mounng
1)Mountthedeviceinthedesiredlocaon(seestep1).
2)Openthelid.
3)Selectthedesiredswitchingpointbyturningtheseleconwheel.
4)Routethecablesthroughthestrainreliefandconnectthecables
properlytotheterminalblock(seestep2).
5)Closethelid.
WARNING!Applypoweronlyaerthedeviceisproperlywired.
SCHEMATICS
5
0
200
300
400
2
F
D
I
Y
P
F
E
T
500
P
S
:
0
100
30
a
P
0
NO NC COM
2 3 1
2 3 1
DIMENSIONAL DRAWINGS
IP 54
0
P
a
30
100
0
:
S
P
500
T
E
F
P
Y
I
D
F
2
400
300
200
0
5
105.0
92.0
16.0
4.0
55.0
73.0
63.0
STEP 1: MOUNTING THE DEVICE
Mounngposion:
To be installed in vercal posion, either the pressure inlets or the
electrical cable downwards. Select a locaon that provides as much
proteconfromwatersprays(e.g.rain)aspossible.
Figure 1b - Mounng orientaon
5
0
200
300
400
2
F
D
I
Y
P
F
E
T
500
P
S
:
0
100
30
a
P
0
YES YES
NO
5
0
200
300
400
2
F
D
I
Y
P
F
E
T
500
P
S
:
0
100
30
a
P
0
5
0
200
300
400
2
F
D
I
Y
P
F
E
T
500
P
S
:
0
100
30
a
P
0
5
0
200
300
400
2
F
D
I
Y
P
F
E
T
500
P
S
:
0
100
30
a
P
0
NO
5
0
200
300
400
2
F
D
I
Y
P
F
E
T
500
P
S
:
0
100
30
a
P
0
Copyright HK Instruments 2018 www.hkinstruments. Installaon version 6.0 2018
STEP 2: WIRING DIAGRAMS
Thesellerisobligatedtoprovideawarrantyofveyearsforthedeliv-
eredgoodsregardingmaterialandmanufacturing.Thewarrantyperiod
isconsideredtostartonthedeliverydateoftheproduct.Ifadefect
inrawmaterialsora produconawisfound,thesellerisobligated,
whentheproductissenttothesellerwithoutdelayorbeforeexpira-
onofthewarranty,toamendthemistakeathis/herdiscreoneither
by repairing the defecve product or by delivering free of charge to
thebuyeranewawlessproductandsendingittothebuyer.Delivery
costsfortherepairunderwarrantywillbepaidbythebuyerandthe
return costs by the seller. The warranty does not comprise damages
causedbyaccident,lightning,oodorothernaturalphenomenon,nor-
malwearandtear,improperorcarelesshandling,abnormaluse,over-
loading,improperstorage,incorrectcareorreconstrucon,orchanges
and installaonworknot donebytheseller.Theseleconof materi-
alsfordevicespronetocorrosionisthebuyer’sresponsibility,unless
otherwise is legally agreed upon. Should the manufacturer alter the
structureofthedevice,thesellerisnotobligatedtomakecomparable
changestodevicesalreadypurchased.Appealingforwarrantyrequires
thatthebuyerhascorrectlyfullledhis/herduesarisenfromthede-
liveryandstatedinthecontract.Thesellerwillgiveanewwarrantyfor
goodsthathavebeenreplacedorrepairedwithinthewarranty,how-
everonlytotheexpiraonoftheoriginalproduct’swarrantyme.The
warrantyincludestherepairofadefecvepartordevice,orifneeded,
anewpartordevice,butnotinstallaonorexchangecosts.Underno
circumstanceisthesellerliablefordamagescompensaonforindirect
damage.
WARRANTY POLICY
ForCEcompliance,aproperlygroundedshieldingcableisrequired.
1)Unscrewthestrainreliefandroutethecable.
2)ConnectthewiresasshowninFigure2.
3)Tightenthestrainrelief.
Figure 2 - Wiring diagram
NO
23 1
NC COM
P
RECYCLING/DISPOSAL
The parts le over from installaon should be
recycled according to your local instrucons.
Decommissioned devices should be taken to a
recyclingsitethatspecializesinelectronicwaste.

This manual suits for next models

5

Other HK Instruments Switch manuals

HK Instruments DPI Series User manual

HK Instruments

HK Instruments DPI Series User manual

HK Instruments PS Series User manual

HK Instruments

HK Instruments PS Series User manual

HK Instruments PS Series User manual

HK Instruments

HK Instruments PS Series User manual

HK Instruments DPI Series User manual

HK Instruments

HK Instruments DPI Series User manual

Popular Switch manuals by other brands

Cisco Nexus 9000 Series Configuration guide

Cisco

Cisco Nexus 9000 Series Configuration guide

Bosscom Powerlink Switch Airplay user manual

Bosscom

Bosscom Powerlink Switch Airplay user manual

Allied Telesis AT-8000S/24POE datasheet

Allied Telesis

Allied Telesis AT-8000S/24POE datasheet

Cisco WS-X6066-SLB-APC - Content Switching Module Installation note

Cisco

Cisco WS-X6066-SLB-APC - Content Switching Module Installation note

BD Sensors DM 200 Mounting instructions

BD Sensors

BD Sensors DM 200 Mounting instructions

DeviceWell HDS7106 user manual

DeviceWell

DeviceWell HDS7106 user manual

LEGRAND Pro 21 7756 21 instruction manual

LEGRAND

LEGRAND Pro 21 7756 21 instruction manual

HP A3600-24 v2 Disassembly instructions

HP

HP A3600-24 v2 Disassembly instructions

Kenco KUSO Installation & operation instructions

Kenco

Kenco KUSO Installation & operation instructions

TRENDnet TEG-S2620i user guide

TRENDnet

TRENDnet TEG-S2620i user guide

schmersal AZM300B-I2-ST-SD2P-DU Instructions for operation

schmersal

schmersal AZM300B-I2-ST-SD2P-DU Instructions for operation

KTI Networks KS-124 user guide

KTI Networks

KTI Networks KS-124 user guide

Intermatic EMDS installation guide

Intermatic

Intermatic EMDS installation guide

ATEN CL5808 Specifications

ATEN

ATEN CL5808 Specifications

ADLINK Technology CSA-7400 quick start guide

ADLINK Technology

ADLINK Technology CSA-7400 quick start guide

Rockwell Automation Allen-Bradley Guard master MC2 Product information

Rockwell Automation

Rockwell Automation Allen-Bradley Guard master MC2 Product information

NETGEAR ProSafe GS116v2 installation guide

NETGEAR

NETGEAR ProSafe GS116v2 installation guide

technetix AIMA-OPSW Product user manual

technetix

technetix AIMA-OPSW Product user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.