1/3
SETTING OF SPEED METER (EG-N2N)
AND INSTRUCTION MANUAL
(1)ARRANGEMENT OF SW1 DIP SWITCH AND SHORT CHIP:
“LOCK ON”SWITCH﹐WHEN IT WAS
SWITCHED“ON”﹐IT CAN BE SET H. L. ONLY
(2)DESCRIPTION OF CODE (IT WILL DISPLAY IN
FOLLOWING SEQUENCE AT THE FACE BOARD):
BASIC RATIO VALUE。
HSETTING OF HIGH LIMIT AL2。
LSETTING OF LOW LIMITAL1。
BASIC TIME BASE OF VALTAGE﹐CURRENT﹐FREQUENCY﹐
IT HAS BEEN SET BEFORE SHIPMENT(EACH UNIT ID IS
1ms)
UACCELERATING TIME BASE OF SPEED SETTER(EACH
INCREMENT IS UNIT 1ms)﹐WHEN SET “0”﹐IT IS 0.5ms.
DECELERATING TIME BASE OF SPEED SETTER(EACH
DECREMENT UNIT IS 1ms)﹐WHEN SET “0”﹐IT IS 0.5ms.
PSHIFTING OF DECIMAL POINT(0~4 DIFFERENT SETTING):
0ALL INTEGERS﹐NO DECIMAL。
1DECIMAL POINT IN ZERO INTEGER。
2FOLLOWING DECIMAL POINT HAVE ONE INTEGER。