- 13 -
confirmed and reported and the outdoor system will be stopped.
3.13 Special features
3.13.1 Single indoor system operation
* Enter condition: First, set the high speed airflow and 30 centigrade set temperature, then
press the dormant keys for 6 times within 7 seconds, the system will feedback with 6 rings.
* After the system enters the separate indoor system operation mode, the indoor system will
operate according to the set mode and neglect the communication signals of the outdoor system.
However, it has to send signals to the outdoor system.
* Quitting condition: This mode can be quitted after receiving the quitting signal from the remote control or
urgency system. The indoor system thus can quit the single operation
3.13.2Power-off compensation.
* Entering condition: Press dormant button 10 times within 7 second, the buzzer will ring 4
times and the present system status will be stored into the EEPROM of the indoor system.
* After entering the power cut compensation mode, the processing of the indoor system should be as the
followings:
Remote control urgency singal: operate according to the remote control and the urgent conditions, the present
status will be stored into the EEPROM of the indoor system.
* Quitting conditions: Press dormant button 10 times within 7 seconds and the buzzer will ring twic
3.13.3.Fixed frequency operation.
3.13.3.1Fixed cooling: a. under G code condition: high speed cooling, set 16 ć, press
temperature
þ-þkey and the set key at the same time. The system will enter the fixed frequency
operation after the buzzer rings twice.
b. The proceeding programs are as the follows:
Entering the fixed frequency operation, you can set the fixed strength location 1 and send the
coolng signal to the outdoor system. Meanwhile, you can fix the indoor system at high speed
mode, the location of the airflow directin board can be switched to the maximal position.
c. Quitting condition: The fixed frequency cooling can be quitted after receiving the remote
signal, and the system will enter the remote setting status.
3.13.3.2. Fixed heating: a. under G code condition: high speed heating, set 30ć, press
temperature
þ+þkey and the set key at the same time. The system will enter the fixed frequency
operation after the buzzer rings twice.
b. The proceeding programs are as the follows:
Entering the fixed frequency operation, you can set the fixed strength location 1 and send the
heating signal to the outdoor system. Meanwhile, you can fix the indoor system at high speed
mode, the location of the airflow directin board can be switched to the maximal position.
c. Quitting condition: The fixed frequency heating can be quitted after receiving the remote
signal, and the system will enter the remote setting status.
3.14ˊOther additional functions.
3.14.1 Test program
First, connect the test program terminal on the mainboard, then connect the system to the power
circuit. The test program will operate as follows.
HV series display: The buzzer rings for one timeüthe signal will be sent to outdoor system
for 0.5 secondüthe violet is sent for 0.5-- the background light turns to whiteüthe back
ground light turns to whiteüthe background light turns to whiteüthe background light is fully
lighted for 0.5 secondüLCD screen lights for 0.5 secondüthe step-in motor fully output for
0.5 secondüthen the motor doesnÿt output for 0.5 secondüthe motor fully output again for