OCSUserGuide

OCSUserGuide
Content
1. SAFETY GUIDE 1
2. FEATURES 1
3. SPECIFICATIONS 2
4. QUICK START 3
POWER ON3
ZERO 4
TARE IN4
TARE OUT 5
HOLD 5
POWER OFF 6
5. USER INPUT 7
KEYS ON SCALE 7
KEYS ON REMOTE CONTROLLER 7
INPUT NUMERALS 8
6. ADVANCED OPERATION 9
SCALE’S MODE 9
WEIGHING MODE 9
GROSS/NET MODE 9
VIEW TOTAL MODE 9
IDLE MODE 10
2ND MODE 10
PASSWORD MODE 11
TOTAL 11
VIEW TOTAL 12
DELETE LAST TOTAL 12
CLEAR TOTAL 13
DISPLAY UNIT SWITCH 13
TARE SET 14
RESOLUTION SWITCH 15
BATTERY CHECK 15
SYSTEM SETUP 16
RESOLUTION 16
AUTO POWER-OFFTIMING 17
IDLE TIMING 17
DISPLAY BRIGHTNESS 17
DISPLAY FREQUENCY 18
ANTI-MOTION LEVEL 18
COMMUNICATION SETUP 18
COMMUNICATION ON/OFF 19
BAUD RATE 19
SCALEADDRESS 20
OUTPUT MODE 20
7. BATTERY 21
8. MESSAGE ILLUSTRATION 22
9. TROUBLESHOOTING 23
10. NOTES 24

OCSUserGuide
Page1of24
1. Safety Guide
Forgoodperformanceandprecisemeasurement,becarefulwithdailyoperationandmaintenance.Notethefollowing
instructions:
▫DoNOToverloadthescale.Thiswilldamagetheloadcellandvoidthewarranty.
▫DoNOTleaveloadhungonthescaleforlong.Thiswilldecreasethescale’saccuracyandshortentheloadcell’s
life.
▫Inspectshackleandhookbeforeusing.Checktheclips,pinsandscrewsregularly.
▫Checkthebatterypowerfrequently.Whenthescalerunsoutofpower,chargethebatterywithitsdedicated
chargerorreplaceitwithafullone.
▫Rotatetheloadratherthanthescaleitselfifneeded.
▫DoNOTusethescaleunderthunderorrain.
▫Hangscaleonshelfindryandwell‐ventilatedroom.DoNOTplacescaleonthegrounddirectly.
▫DoNOTattempttorepairthescaleyourself.Contactyourlocalrepresentative.
2. Features
Thisscaleisacombinationofthesoundandprovenmechanicaldesign,withtoday’smostadvancedelectronicsto
provideasuperbfeatureset.Itisversatile,reliable,accurateandeasytooperate.
▫SuperbQuality:
StrictlyinaccordancewithOIMLR76,ChineseGB/T11883‐2002nationalstandards,andEuropeanCEdirectives.
▫GreatSafety:
Aluminum‐castingcase,highfirmhookandring,dedicatedweighingloadcellforsafetyinstallation.
▫StrongReliability:
Cutting‐edgetechnology,qualityintegratedcircuitforhighperformanceandlongtimestability.
▫BroadApplicability:
Popularandapplicableinstorage,textile,metallurgyindustry,andsoforth.
▫EasyOperation:
Ultra‐redremotecontrollingdesign.Easytooperateonthescaleorindistance.
■CompleteFunction:
Divisionswitching,measurementunitconversion,automaticpowersave,automaticbatteryinspection,idlemodefor
batterysave,presetabletare,etc.

OCSUserGuide
Page 2 of 24
3. Specifications
AccuracyClassChineseGB/T11883‐2002ClassIII
EquivalenttoOIMLR76
TareRange100%F.S.
ZeroRange4%F.S.
ReadingStableTime≤10seconds
OverloadWarning100%F.S.+9e
Max.SafetyLoad125%F.S.
UltimateLoad400%F.S.
BatteryLife80hours~200hourswith6V/10Ahbattery
60hours~100hourswith6V/5Ahbattery
ScaleBattery6V/10Ahor6V/5Ahrechargeablebattery
OperatingTemp.‐10₤~+40₤
OperatingHumidity≤90%at20₤
Display1.5inch(38.1mm)ultra‐luminanceLED
1.2inch(30mm)ultra‐luminanceLED

OCSUserGuide
Page3of24
4. Quick Start
ThisQuickStartintroductionwillguideyouthroughthesebasicoperationsonthecranescale.Tomakefulluseof
thisversatilescale,pleasereferto5AdvancedOperationsection.
PowerOn
Action
ToPOWERONthescale,pressON/OFFbuttononscalefor1second.
Function
Scalegoesthroughpower‐ontest,batterycheckandinitialization.
Condition
;Power‐ontestisperformedwhendisplayflashesthefollowingcharacterstwice.Ifscale
doesn’tpassthetest,errormessagewillbeflashed.
Scale’smaximumcapacitywillbedisplayedonthescreen.Forexample,thescaleshowsits
fullcapacity,5000kg.
BatteryCheckisthenperformed.Ifbatteryworkswell,thescreenflashesbatterycharge
twice.
Pleaseflipto7Batterysectionformoreinformationaboutbatteryrecharging.
;Finally,thescreenshowsdetectionmessagewhilescaledetectsitsloadandAUTO‐ZERO
itselftoZEROstatus,whentheAUTO‐ZEROfunctionisenabled.
TolearnmoreaboutAuto‐Zerofunction,refertoAuto‐ZeroRangeinScaleConfiguration
functionfordetails.
WARNING:
Scale must work at the battery voltage ranging from 6.80V to 5.80V.
Recharge the battery when needed.
POWER ON

OCSUserGuide
Page 4 of 24
Afterscaleiscompletelypoweredup,itisreadytoweighloads.
Zero
Action
ToZEROthescale,pressZERObuttononscaleor onremotecontroller.
Function
ScalesetscurrentloadtobeZERO,asifithasnoload.
TheZEROindicatorlightson.
Theweightreadingturns“0”,(or“0.0”or“0.00”,dependingontheresolution).
Condition
;ThescalemustnotbeinHOLDmode.Otherwise,errormessage willkeep
flashing.
;Thescalemustbestable.Otherwise,errormessage willflash.
;CurrentweightreadingisinMANUAL‐ZERORANGE.Otherwise,errormessage
willflash.
TolearnmoreaboutManual‐ZeroRange,pleaserefertoScaleConfigurationfunction.
TareIn
Action
ToTAREINatareweightintoscale,pressTAREbuttononscaleor onremote
controller(whenthescaleisinGROSSMODE).
Function
Thescalestoresatareweight,andshiftstoNETMODE.Allsubsequentreadingsare
deviationsfromthetarevalue.
TheTAREindicatorlightson.
Theweightreadingturnsto“0”(or“0.0”or“0.00”,dependingontheresolution).
Condition
;ThescalemustnotbeinHOLDmode.Otherwise,errormessage willkeep
flashing.
ZERO
TARE IN

OCSUserGuide
Page5of24
;Thescalemustbestable.Otherwise,errormessage willflash.
;Currentweightreadingmustbegreaterthan0(or0.0or0.00,dependingontheresolution).
Otherwise,errormessagewillflash.
;Currentweightreadingmustbefewerthan100%scale’sMAXIMUMCAPACITY.Otherwise,
errormessagewillflash.
;Thescalemustbeingrossmode.Otherwise,thisactionwillberecognizedasTAREOUT.
TareOut
Action
ToTAREOUTthetareweightoutofscale,pressTAREbuttononscaleor onremote
controller(whenthescaleisinNETMODE).
Function
Thescaleclearsthetareweight,returnstogrossmode,anddisplaysallsubsequent
readingsinGROSSMODE.
TheTAREindicatorlightsoff.
Theweightreadingisaddedwithtareweight.
Condition
;ThescalemustnotbeinHOLDmode.Otherwise,errormessage willkeep
flashing.
;ThescalemustbeinNETMODE.Otherwise,thisactionwillberecognizedasTAREIN.
Hold
Action
ToHOLDtheweightreading,pressHOLDbuttononscaleor onremotecontroller.
Or
Tounlockcurrentreading,pressHOLDbuttononscaleoronremotecontrolleragain.
Function
TheHOLDindicatorlightson.
Allsubsequentreadingsarelockedtocurrentreading.
Or
TheHOLDindicatorlightsoff.
Theweightreadingisunlocked.
Condition
;ToHOLDthescale,itmustbestable.Otherwise,errormessage willflash.
NOTICE:
Setting or changing TARE has no effect on the ZERO setting.
NOTICE:
Tareing will reduce the apparent overloading range of the scale.
For example, if a 1000kg container is tared and the scale maximum
capacity is 5000kg, the scale will overload at a new weight of 4009kg (5000
– 1000 + additional 9 divisions).
HOLD
TARE OUT

OCSUserGuide
Page 6 of 24
PowerOff
Action
ToPOWEROFFthescale,pressON/OFFbuttononscaleor onremotecontrollerfor2
second.
Function
ScaleperformsBATTERYCHECKandcutoffitspower.
Thescreenflashesbatterychargetwice.
ThescreendisplaysPOWEROFFmessage.
Condition
ThescalemustbeinWEIGHINGMODE.Otherwise,thisactionwillreturnthescaleto
WEIGHINGMODEandthenperformPOWEROFF.
POWER OFF
NOTICE:
Scale can be unlocked at anytime in HOLD mode.

OCSUserGuide
Page7of24
5. User Input
Inthissection,youwilllearnhowtooperatethisscaleinaconvenientwayeitheronscaleorbyremotecontroller.
Detailedoperationsaredescribedinsection3QuickStartandsection6AdvancedOperation.
KeysonScale
ON/OFF ZERO TARE HOLD 2ND
PowerOffPowerOn
WeighingModePowerOff ZeroTareIn
Hold2nd
TareOut
2ndModeExitDisplay
UnitSwitch TareSetSystem
SetupPassword
PasswordExit↑→Confirm
TareSetExit↑→Confirm
SystemSetupExit↑→ConfirmSave
IdleModeWakeUpWakeUpWakeUp WakeUp WakeUp
KeysonRemoteController
Weighing
Mode
2nd
Mode
Idle
Mode Password TareSetSystem
Setup
Zero
Display
Unit
Switch
Wake
Up
↑↑↑
TareIn
TareSetWake
Up
→→→
TareOut
HoldSystem
Setup
Wake
UpConfirmConfirm Confirm
TotalResolution
Switch
Wake
Up
↓↓↓
Clear
Last
Clear
Total
Wake
Up
←←←
View
Total
Battery
Check
Wake
Up
Pricing
ModePriceSetWake
Up
Power
OffExitWake
UpExitExitExit
2nd
ModePasswordWake
Up
Save
KEYS ON REMOTE CONTROLLER
KEYS ON SCALE

OCSUserGuide
Page 8 of 24
InputNumerals
User’sinputofnumeralsarerequiredinPASSWORDMODE,SystemSetupMode,Scale
ConfigurationMode,CalibrationMode,andTareSetfunction.
Action
Toincreasethenumeral(theflashingdigit),pressZERObuttononscaleoron
remotecontroller.
Todecreasethenumeral(theflashingdigit),pressonremotecontroller.
Tomoverighttheflashingdigit,pressTAREbuttononscaleoronremotecontroller.
Tomovelefttheflashingdigit,pressonremotecontroller.
Toconfirmthenumeralsyouinput,pressHOLDbuttononscaleoronremote
controller.
INPUT NUMERALS

OCSUserGuide
Page9of24
6. Advanced Operation
Operationsinthissectionfeatureversatileandpowerfulfunctionsforcranescalemeasurement.Mostofthe
operationsareaccessibleviadedicatedremotecontroller.Someofthesettingstothescalerequirepassword.Please
contactyourlocalrepresentativesforpasswordinformation.
Scale’sMode
WeighingMode
Action
NobuttonsorkeysarerequiredtoenterWEIGHINGMODE.
Function
WEIGHINGMODEisthedefaultmodeafterthescaleisturnedon.InWEIGHINGMODE,
scaledetectsitsload,andrefreshestheweightreadingallthetime,ifthedisplayisnotHold.
Ifthescaleoverloads,thedisplaykeepsflashingthebelowerrormessage.
Gross/NetMode
Action
ToenterNETMODE,TAREorTARESETthescale
ToenterGROSSMODE,TareOutthescale.
Function
InNETMODE,theTAREindicator lightson.
InGROSSMODE,theTAREindicator lightsoff.
ThedefaultweightreadingisinGROSSMODE.
ViewTotalMode
Action
ToentertheVIEWTOTALMODE,press whenscaleisinWEIGHINGMODE.
Totogglebetweenthelow5digitsformatandthehigh5digitsformat,pressHOLDbutton
onscaleoronremotecontroller.
Function
NOTICE:
InN
ET MODE, ZERO are disabled.
VIEW TOTAL MODE
GROSS/NET MODE
WEIGHING MODE
SCALE’S MODE

OCSUserGuide
Page 10 of 24
InVIEWTOTALMODE,theweightreadingkeepsflashingtodistinguishitselffromthatin
WEIGHINGMODE.
Apparently,TOTAListhesumofhistoryweightreadings,whichcanbesogreatthatthe5
digitsscreenisnotabletodisplaycorrectly.TheTOTAListhereforedividedintotwoparts,the
low5digitsformat,andthehigh5digitsformat.
Forexample,thetotalizedweightreading“129235.0”willbedisplayed“9235.0”asitslow
5digitsformat,likebelow.
Thehigh5digitsformatof“29235.0”islikebelow.
TolearnmoreaboutViewTotal,pleaserefertoViewTotalin6AdvancedOperation
section.
IdleMode
Action
NobuttonsorkeysarerequiredtoentertheIDLEMODE.
Function
InIDLEMODE,thescreendimsitsbrightnesstosavebatterypower.Exceptforthis
power‐savingfeature,alltheoperationsarethesameasinothermodes.
TolearnhowtoconfigureIdleMode,pleaserefertoIdleTimingofSystemSetupin
6AdvancedOperationsection.
2ndMode
Action
Toenterthe2NDMODE,press2NDbuttononscaleor onremotecontroller,when
scaleisinWEIGHINGMODE.
Function
The2NDMODEisdesignedtomakefulluseofkeysonremotecontroller.Differentkey
pressingcombination,resultsindifferentfunction.
2ND MODE
NOTICE:
Any buttons on scale or keys on remote controller will wake the scale
up from its IDLE MODE, light the screen up in result.
IDLE MODE
NOTICE:
All other functions are disabled in VIEW TOTAL MODE.

OCSUserGuide
Page11of24
Toaccessthosefunctionsthatarenotprintedontheremotecontroller,youmust
additionallypressspecifiedkeytoaccessthatfunction.
In2NDMODE,thescreenkeepsflashingthebelowmessage,waitingforuser’sinputofkey
combination.
PasswordMode
Action
ToenterthePASSWORDMODE,press2NDbuttononscaleor onremotecontroller
twice.
Function
Toaccessadvancedsettings,passwordisrequired.
InPASSWORDMODE,thescreendisplaysthepasswordmessage,waitingforuser’sinputof
correctpassword.
Condition
;ThescalemustnotbeinHOLDmode.Otherwise,errormessage willkeep
flashing.
;Thepasswordmustbecorrect.Otherwise,errormessage willflashbeforethe
scaleautomaticallyreturnstoWEIGHINGMODE.
Total
Action
Toaccumulatetheweightreading,pressonremotecontroller.
Function
Currentweightreadingwillbeaccumulatedintoscale’sTOTALaccumulator.
Thescreendisplaysthebelowmessage,indicatingthatTOTALissuccessfullycalculated
andsaved.
Condition
;ThescalemustnotbeinHOLDmode.Otherwise,errormessage willkeep
flashing.
TOTAL
PASSWORD MODE

OCSUserGuide
Page12of24
;Thescalemustbestable.Otherwise,errormessage willflash.
;Currentweightreadingmustbegreaterthan0(or0.0or0.00,dependingontheresolution).
Otherwise,errormessagewillflash.
;Theweightreadingonscalemustreturn0(or0.0or0.00,dependingontheresolution)
beforenextweightreadingcanbeadded.Thisassuresthataloadonthescaleisonly
addedtotheTOTALonce.Otherwise,errormessage willflash.
ViewTotal
Action
ToviewtheTOTALinscale,press onremotecontroller.
Function
ThescaleisswitchedintoVIEWTOTALMODE.
ThescreenflashescurrentTOTAL,forexample,3205kg.
Condition
;ThescalemustnotbeinHOLDmode.Otherwise,errormessage willkeep
flashing.
;TheTOTALmustbegreaterthan0(or0.0or0.00,dependingontheresolution).Otherwise,
errormessagewillflash.
TolearnhowtooperateinViewTotalMode,pleaserefertoViewTotalModeofScale’s
Modein6AdvancedOperationsection
DeleteLastTotal
Action
Todeletethelastaccumulatedweightreading,pressonremotecontroller.
Function
Ifthelasttotaledweightwasamistake,itcanbeerasedbyDELETELASTTOTAL.This
erasesonlythelasttotaledvalue.
Thescreendisplaysthebelowmessage,indicatingthatthelastTOTALissuccessfully
deleted.
Condition
DELETE LAST TOTAL
VIEW TOTAL
NOTICE:
The accumulator always uses the displayed weight, so GROSS and
NET readings can be added into the same TOTAL.

OCSUserGuide
Page13of24
;ThescalemustnotbeinHOLDmode.Otherwise,errormessage willkeep
flashing.
;TheLastTotalmustbegreaterthan0(or0.0or0.00,dependingontheresolution)orhas
notbeendeleted.Otherwise,errormessagewillflash.
ClearTotal
Action
TocleartheoverallTotal,pressand onremotecontrollerinturn.
Function
InordertostartanewseriesofTotals,theoldTOTALcanbeerasedcompletelybyCLEAR
TOTAL.
Thescreendisplaysthebelowmessage,indicatingthattheTOTALissuccessfullyerased.
Condition
;ThescalemustnotbeinHOLDmode.Otherwise,errormessage willkeep
flashing.
DisplayUnitSwitch
Action
Tochangethescale’sDISPLAYUNIT,press2NDbuttononscaleor onremotecontroller,
andZERObuttononscaleoronremotecontrollerinturn.
Function
Thescaleswitchesto2NDMODE,andthenrecognizesZEROactionasDISPLAYUNIT
SWITCHINGaction.DISPLAYUNITSWITCHINGtogglesbetweenkg(metricsystem)andlb
(imperialsystem).
Thescreenflashestheunittochange,andreturnstoWEIGHINGMODE.
Thelbindicator lightson,afterDISPLAYUNITswitchestolb.
Thekgindicatorlightson,afterDISPLAYUNITswitchestokg.
Condition
DISPLAY UNIT SWITCH
CLEAR TOTAL

OCSUserGuide
Page14of24
;ThescalemustnotbeinHOLDmode.Otherwise,errormessage willkeep
flashing.
;ThescalemustbeinGROSSMODE.Otherwise,errormessage willflash.
PleasefliptoSystemUnitofScaleConfigurationin6AdvancedOperationsectionin
TechnicalManualformoreinformationaboutscale’smeasurementsystem.
TareSet
Action
Press2NDbuttononscaleoronremotecontroller,andTAREbuttononscaleor
onremotecontrollerinturn(whenthescaleisingrossmode),toenterTARESETfunction.
PressZEROandTAREbuttononscaleorand onremotecontrollertoinputthe
digits.
PressHOLDbuttononscaleoronremotecontrollertoconfirmtheinputvalue.
Function
Thescalestoresthetareweightthatuserinputs,andshiftstoNETMODE.Allsubsequent
readingsaredeviationsfromthetarevalue.
Thescreendisplays“00000”(or“0000.0”or“000.00”,dependingontheresolution)with
thefirst“0”flashing,waitingforuser’sinput.
Tolearnhowtoinputdigits,pleasereferto5UserInputsection.
Condition
;ThescalemustnotbeinHOLDmode.Otherwise,errormessage willkeep
flashing.
;ThescalemustbeinGROSSMODE.Otherwise,errormessage willflash.
;Theinputtareweightmustbegreaterthan0(or0.0or0.00,dependingontheresolution).
Otherwise,errormessagewillflash.
;Theinputtareweightmustbelesserthanscale’smaximumcapacity.Otherwise,error
messagewillflash.
TARE SET
NOTICE:
Tare setting will reduce the apparent overloading range of the scale.
For example, if a 1000kg is set by tare set function, and the scale
maximum capacity is 5000kg, the scale will overload at a new weight of
4009kg (5000 – 1000 + additional 9 divisions).
NOTICE:
D
ISPLAY UNIT SWITCH function only changes the unitScale does not save
this setting unless SYSTEM UNIT is changed.

OCSUserGuide
Page15of24
ResolutionSwitch
Action
Toswitchscale’sresolution,pressand onremotecontrollerinturn.
Function
Thescreenflashestheresolutiontochangeindescendingorder,like5kg,2kg,1kg
(availableoptionalresolutionrangesfrom0.01kgorlbto50kgorlb,dependingonscale’s
capacity).AfterRESOLUTIONSWITCH,newresolutiontakeseffect.
Tobalancebetweenaccuracyandmeasurementspeedinhighresolutionmode,
ANTI‐MOTIONLEVELcanbechangedtofityourmeasurementapplication.
TolearnhowtosetAnti‐MotionLevel,pleaserefertotheAnti‐MotionLevelin6
AdvancedOperationsection.
Condition
;ThescalemustnotbeinHOLDmode.Otherwise,errormessage willkeep
flashing.
BatteryCheck
BATTERY CHECK
RESOLUTION SWITCH
NOTICE:
R
ESOLUTION SWITCHING will change the apparent overloading range of
the scale. For example, if the resolution of a 3000kg scale is switched to
0.5kg, it will overload at a new weight of 3004.5kg (3000 + 9*0.5), while by
default, it overloads at a weight of 3009kg (3000 + 9*1).
NOTICE:
High resolution offers better accuracy at the cost of longer measuring
time and stricter requirement of load’s stability. Designed to meet the OIML
R76’s directive, this scale has the best (default) performance at 2000 to
3000 division.
NOTICE:
The default resolution will be restored next time when the scale is
powered on or enter System Setup Mode (no matter the setting is changed
or not). To save the changes in resolution for later, use SYSTEM SETUP
function, rather than RESOLUTION SWITCHING.
NOTICE:
Setting or changing TARE has no effect on the ZERO setting.

OCSUserGuide
Page 16 of 24
Action
Tocheckscale’sbatterypower,press and onremotecontrollerinturn.
Function
Systemchecksthebattery,andfeedbackswithbattery’sleftcharge.
Thescreenflashesthebatterychargeinvoltage,likethebelow6.42V.
Pleaseflipto7Batterysectionformoreinformationaboutbattery.
Condition
;ThescalemustnotbeinHOLDmode.Otherwise,errormessage willkeep
flashing.
SystemSetup
Action
ToenterSYSTEMSETUPMODE,press2NDandHOLDbuttononscaleor and on
remotecontrollerinturn.
Toinputdigits,pressZEROandTAREbuttononscaleorand onremote
controller.
Toconfirmthepasswordorinputvalue,pressHOLDbuttononscaleoronremote
controller.
TosaveandexitSYSTEMSETUPMODE,press2NDbuttononscalefor onremote
controller.
ToexitSYSTEMSETUPMODEwithoutsaving,pressON/OFFbuttononscaleor on
remotecontroller.
Tolearnhowtoinputdigitsorchangetheoption,pleasereferto5UserInputsection.
Function
InSYSTEMSETUPMODE,usercanchangethescale’ssystemfunctiontotheirdesiredstate,
likehigherresolution,automaticpower‐offdelay,idledelay,thescreen’sbrightness,display
frequency,andanti‐motionleveletc.
Thescreendisplaysthewelcomemessageasbelow.
Condition
;ThescalemustnotbeinHOLDmode.Otherwise,errormessage willkeep
flashing.
Resolution
SYSTEM SETUP
RESOLUTION

OCSUserGuide
Page17of24
Technically,theRESOLUTIONhereandtheRESOLUTIONSWITCHabove‐mentionedboth
refertothesamething.Theonlydifferenceisthatchangesmadeherecanbesavedforlater,
whilechangesatRESOLUTIONSWITCHonlycomeintoeffectthistime,butnotnexttimewhen
thescaleisrebooted.
TolearnmoreaboutResolution,pleaserefertoResolutionSwitchin6Advanced
Operationsection.
AutoPower‐OffTiming
AUTOPOWER‐OFFfunctionmaximizesscale’sbatterylifeagainstpeople’scarelessnessnot
topoweroffthescalewhenit’snotworking.
AUTOPOWER‐OFFstartsthescale’sPOWER‐OFFcountdowntimerwhenthere’snoactionor
theloadisstable.Oncethetimer’stimingreachesthedelayusersetinSYSTEMSETUP,it
automaticallypoweroffthescale.Anykeypressingormotioninload,willrestartthe
countdowntimer.
Scalecanbetimedtoautopower‐offitselffrom“01”minutesto“99”minutes,or“never”
whenAUTOPOWER‐OFFTIMINGissetto“00”.
ThedefaultAUTOPOWER‐OFFTIMINGissetto“15”minutes.
IdleTiming
Tomaximizeitsbatterylife,thescaleautomaticallyenterstheIDLEMODE,whenthere’sno
actionortheloadisstable.InIDLEMODE,thescaleworksinlow‐powerconsumptionstatus.
“01”secondsto“99”secondscanbesettoscale’sIdlecountdowntimer.Oncethetimer’s
timingreachesthedelayuserset,itautomaticallylowersthebrightnessofthescreen.IfIDLE
TIMINGissetto“00”,thescalenevergoesintoIDLEMODE.
Anykeypressingormotioninload,willwakeupthescalefromIDLEMODE(whenitisin
thismode),andrestartthecountdowntimer.
ThedefaultIdleTimingissetto“30”seconds.
DisplayBrightness
AUTO POWER-OFF TIMING
IDLE TIMING
Table of contents