HOME ALARM 4099 User manual

1

2
BEFORE INSTALLING AND USING THIS SYSTEM, YOU ARE STRONGLY
RECOMMENDED TO READ THIS MANUAL CAREFULLY.
一、 BEFORE USING THE SYSTEM:
1. Make sure all the arming zones are working normally.
2. Avoid heavy impacts and unnecessary disassembly which might incurs accident or man-made
damage.
3. When installing, avoid touching the electronics components which on the PCB with hand or metal
parts.
4. When installing, make sure the AC power supply is stable (if the AC power supply is cut, the system
will shift to backup battery automatically).
5. The unit has alarm priority function. Make sure main unit is connected with telephone line so that it can
automatically dial the presented phone number.
6. Make sure you have charged the system for at least 12 hours uninterruptedly before using the system
for the first time.
7. Low voltage of the batteries in the main unit may cause constant beeps from main unit or subnormal
display on the LCD.
二、Main features and functions
(1)Built-in 16 wireless defense zones and 8 wired defensive zone microcomputer control
(2)Keyboard operation ,English LCD display for menu
(3)Latest American CPU processing circuit.
(4) CPU code
(5) CMS optional ,support Ademco Contact ID.

3
(6) Independent defense zone setting
(7) Multi-way to arm and disarm (by remote controller, keyboard ,regular,mobilephone)
(8) 36 event log that easily be managed the alarming scene
(9) listen to the record and monitor the alarming scene using mobile phone when receiving phone
calls.
(10) Door lock systems controlled by ID card
(11) Panic alarm
(12) Built-in 85 db siren
(13) Alarm time display
(14) 12v power supply outlet for wired accessories
(15) alarming zones alert with sound
三、Main parts name and instruction(see Picture 1)
(一)Built in DIP switch(Picture 1):
Picture 1

4
N
o.
Position
Pin switch
ON OFF
1
Remote
control switch
Enable (DEFAULT)
Disable
2
Password
Reset switch
Reset system
If you forgot password, you can put this DIP to
ON, then turn off the power, then turn on the
power again, the system’
s password will return to
“000000”. After resetting the system, remember to
put the DIP back to OFF position
Normal (DEFAULT)
3
CMS format
Switch
AOLIN format(DEFAULT) Ademco Contact ID
format
4
CMS
connection
Switch
Dial the phone number of CMS Not dial the phone
number of
CMS(DEFAULT)
(2). front(Picture 3)

5
(Picture 2)
(1) power supply indicator( red): Permanently on when turning on the control panel
(2) arm/disarm indicator(red) –arm : Permanently on when under status of arming, off when the
unit is disarmed.
(3)AC fault indicator (red): Permanently on AC power supply is off AC.
(4)LCD display : display for menu and alarm event log
(5) keyboard: for operation and card reading
(三)side(Picture 3)

6
(Picture 3)
(1) Antenna: Pull out the antenna when operating the unit for better signal receiving.
(2)Microphone: For monitor the alarming scene through Mobilephone.
(四)ARCHITECTURE OF THE CONTROL PANEL(Picture 4)
(Picture 4)
(1) Telephone port: AC:18V input,For connection of power transformer(connected)
Phone In: for connection of the main phone line

7
(Notice:If the system shares a same phone line with your daily-used telephone ,make sure the main
phone line goes in the system first, then you can connect yours telephone to the PHONE OUT
connector. This is to eliminate the possibility of faiture in the telephone which might block the
system to get in touch with you when there is a alarming)
(2) 12V DC:For connection of wired accessories
(3) SPK:For 12V/1A external speaker
LED:For showing the working status of the unit (notice:a current around 4.7k resistor is needed to
be in series connection with the LED lamp)
E.L.:Interface for electronic lock of door entry system. External power supply is needed.
BLU RED:For keypad ,BLU for black,RED for red
YEL GRN:For keypad or other accessories of BUS,YEL for yellow,GRE for green
1—-8 wired zone :for wired protective zones, Each interface needs one 2.2K resistor be connected.
(Zone 1 is for smoke/gas detectors, this zone is always in armed status for safety reason)
四、menu and operation
1. remote controller(Picture 5)
Arm : press the button once, the mainframe will give a short
“Bi” once to enter audio alarm status; press the button again, the
mainframe will sound “BI-BI” twice ,then the system will enter
mute alarm status.
Disarm : when the control panel is alarming, press the button
to stop it.
Panic : No matter what status is the control panel, press this
button once the control panel will alarm immediately.
Stay : Press the button to alter arm or disarm status for different
zones .
Quick entry + , the control panel enters arm status without
any delay.

8
(Picture 6)
(5)Keypad (picture 6)
1、KEY
A.
* : cancel the present operation and go to the previous menu.
# : confirm the present operation and go to the next menu
ARM:
(1) As cursor key under status of setting or as the backspace key when editing.
(2) Press the button once, the mainframe will give a short “Bi” once to enter audio alarm status.
STAY:Press the button to enter the presetted particially alarm .
PANIC:No matter what status is the control panel , Quick press this button 3 times, the control panel will
alarm immediately and dial the preset phone number.
MUTE:(1)。As cursor key under status of setting
(2). press the button, the control panel will sound “BI-BI” twice ,then the system will enter mute alarm
status.
B. quick arming via keyboard (3 ways):
①:keep pressing * for 3 second until hearing a short sound under disarming status, the control
panel enter 8 wired and 8 wireless defense zone(from left to right),then press “ 0” to turn off the
defense zone that cursor key locates, press “1” to turn on the defense zone that the cursor key

9
locates , the control panel enter the arming status if pressing “#”.(the control panel will never store
the setting for next time using this way )
②:”arm” for turning on all audio defense zone and “mute” for turning on all mute defense
zone (the control panel has memory function if using the way for setting)
③:”stay” for particail defenses zone setting (the control panel has memory function if using
the way for setting)
C.quick disarming via keyboard
Press “#” and insert code, then press “#“ under arming status
3. System settings & functions
(1) Enter system setting
Make sure the control panel is in disarmed status, then enter the MENU (default setting is disarmed).If
the system is in armed status, you need to enter the disarming password (default 000000),then press “#
“ to confirm to enter the system setting status, The control panel will sound BIBI and the programming
indicator is on if the password is correct .The control panel will sound BIBIBI if the password is not
correct.
(2) Exit system setting
Under the status of setting ( not under the subtitle status), press “ # # “ to exit ,programming indicator
is off.
The system will exit automatically if you have no operation with 20 seconds
(1).Modify the default password
max. length of the password is 6 numbers
(2).Modify the system display time
after enter new time, press “#” to confirm.
(3).Telephone setting
“Menu” – “telephone setting” ,input the 1st telephone number and press “#” to confirm,
press “ arm ” or “ mute ” to select the “ telephone 2 ” ,then input the 2nd telephone

10
number ,repeat the process to set the 3rd telephone, press “arm” to modify the input
number.
(4).CMS
The system can be connected with centre monitoring station ,CMS telephone number and
user’s code is needed.
(5).Record and record playback
Record is for recording message that can be heard when receiving alarm call from the control
panel, the max. length of the record is 20 sec.
Playback is for testing the record contents from the control panel.
4.2 advantage menu
4.2.1 code learning
4.2.1.1 remote controller
Each remote controller can be set freely to control the wish defense zone.
Select “code learning for remote controller” ,press “#”,the LCD displays “code is learning”,press
any button on the remote controller for 3 seconds .The code learning is successful when you
hear ”DIDI”, The LCD displays interface of defense zone setting, all defense zones are selected
in original, the cancel or select the defense zone by using button ”arm”, ”mute”, 0”, ”1”, press “#”
to confirm the setting and then set the next remote controller, press “*” to exit after all the remote
controllers have been set .
Remark: Max. 10 remote controllers can be learnt.
4.2.1.2 detector
select “code learning for detector”and press ”#” ,the LCD displays “please input defense zone

11
No.”,press “#” again after input the defense zone No., press the code learning button on the
detector for 3 second when seeing “* * defense zone code is learning” display on the LCD ,the
code is successfully learnt when hearing “DIDI”.
Remark:
1. the defense zone number can only be input from 1 to 16 and 9 to 16 can’t be set as on
or off after learning the code.
2. max.5 detectors can be learnt for each defense zone.
4.2.2 Accessories cancellation
4.2.2.1 Remote controller
select “ cancel all the remote controller ” ,press “ # ” to confirm or “ * ” to cancel.
4.2.2.2 detector
input the defense zone and press “#” to confirm or “*” to cancel.
4.2.3 defense zone setting
This unit is divided into 8 wired and 16 wireless defense zones, but only
the 8 wired and 1-8 wireless defense zones can be reset. the rest 9-16
wireless defense zones can not be partially selected .
4.2.3.3 24-hour defense zone
24-hour defense zone is normally for connecting with gas detector ,smoke detector or active
detector etc. zone 1 is the default 24-hour defense zone and 24-hour zone can be reset to other
zones simply press “arm” or “mute” and “1” to select and “0” to cancel.

12
4.2.3.4 alarm delay zone
the alarm delay zone is mainly for the special defense zone that needs delay alarm after the
unit is triggered.”advantage menu”- “system setting”-“enter alarm delay” and set the time for
delay.
4.2.4 ID card
4.2.4.1 Id card code learning
The LCD displays “please read the card” after entering the ID card code learning menu,
read the card that need to learn the code, then use”arm”,”mute””0””1””#”or “*”to finish the
code learning.
Note: 1. door entry system module need to be connected with keyboard line before
operation.(details see its manual)
Each card can be learnt to the keypad and the door entry system.
4.2.4.4 module ID card property
Door entry system: 1 second signal will be transmitted for opening the door and disarming
the related defense zones when ID card read on the system
Remark:①To active the ID card on both keyboard and entry system, the code should be
learnt on both of them. Then the related defense zones will be disarmed at the same time
when the door is opened by reading the card on the module.
②The door will be opened but the defense zones will be still on arming status if the ID
card is only learnt on the module.
4.2.5 Shelf check
Test before using the unit to make sure if it works well.

13
4. 2. 6 Event log
4. 2. 6. 1 check the event log
input an event log number and the last alarm time and zones will be displayed on the
LCD, then check other event logs by using “arm” or “mute”
Note: the max. event log is 36 pcs.
4.2.7 system setting
4.2.7.1 arming delay: to set the arming delay time from the moment pressing down the
arming button to the arming status. (Available time 0-99sec., default 30 sec)
4.2.7.2 alarm delay: to set the alarm delay time from the moment that the unit is triggered
to begin to alarm.(available time :0-99sec.,default 0 sec.)
4.2.7.3 alarming: to set the alarming time that lasts.(available 0-1800sec.,default 30 sec.)
4.2.7.7 wireless accessory format
4. 2. 7. 7. 1 AOLIN (recommend)
4. 2. 7. 7. 1 PT2264
4.2.7.8 CMS format
4.2.7.8 .1 Aolin (only used with Aolin control panel)
4.2.7.8 .2 CONTACT ID ( Ademco )
4.2.7.9 telephone line disconnection
Set the detecting function of the phone line when the system is armed. The unit will make
alarm and the event will be displayed on LCD Screen if the telephone line is disconnected if the

14
detecting function is being set.
4.2.7.10 restore default setting
This option will restore all the setting into factory default status
4.2.8 time arming and disarming
4.2.8.1 time arming
Select on to turn on the time arming function and select the exact date during a week:
Press “1” and the day of the week which the cursor located is selected or press“0”to cancel the
selecting. Press “ARM” or “Mute” to move the cursor up or down.
To confirm the selected day ,press “#” then select the time of these days for arming .
4.2.8.2 time disarming
Same as 4.2.8.1
If the time arming and time disarming has been confirmed ,press “*” to exit, the
Screen will be displayed the modification information if the system has been modified. Please
press “*” again to confirm the modification .
5. Alarm and remote control
5.1 The system can be set as audio alarm or mute alarm
(1)audio alarm
When the system is triggered ,the control panel will automatically dial the preset telephone numbers
for 3 circles and the siren will alarm at the same time if the system is not stopped by the user’s
instruction.

15
Picture 8
(2)Mute alarm
If mute alarm is selected, the systems will autodial the preset phone No. and the siren will never
make a sound when the system is being triggered.
Note: the setting will never be successful if any of the below items are not set. ①input preset
Telephone numbers ②telephone line should be inserted.
5.2 CMS alarm
If the system works with CMS, the 4th and the 5th group of telephone numbers (the CMS telephone
Number and the user’s data)should be input. the auto dialer will work as what is demonstrated in Pic 9.
Picture 9
5.3 Remote control the alarming calls
If the user picks up the phone when receiving calls from the system, he will hear a recorded voice
message and can take follow actions:
Press “3#” on the phone: To listen to the sounds from the alarming scene. The time duration is 20

16
seconds. Within this 20 seconds, each press on the “3#” can delay the duration for another 20
seconds. If there is no operation within the 60 seconds, the phone will be hung up automatically and
the auto dialer will continue to call other preset phone numbers.
Press: “5#” on the phone, to make the siren sound at once. The phone will be hung up immediately
and the auto dialer will continue to call other preset phone numbers.
Press: “1#” stop the present alarming. The system is still under the arming status.
Press: “ 0#” disarm.
Press:”6#” : to report the alarm status
Press:”7#” : to check the operation menu
Note: The system will never dial the telephone number that has operated on the keyboard.
5.4 remote control the system
Dial to the telephone that connected with the control panel, the phone will ring for 40 Seconds,
then you will hear “please input the password and press “#” to confirm” if the password is
right, you will hear “press 0# to disarm, press 1# to arm and press 3# to monitoring the
alarming scene”.
Note: this functions will never be available if the No.1 of the 4-No. code switch is not on “ON”.
Ⅴ. install the system
1) Before using, all the wireless accessories must be enrolled to the system. Make sure the protection
zone you need is under ON status.
2) The mainframe should be installed in the center of the entire protection area; this will be good for the
wireless transmitting.
3) Before using the system for the first time, make sure the unit is fully charged the batteries for lest 24
hours. The fully charged back-up batteries can provide the system for 20 hours power if external
power supply is out.
4) Avoid giant metal objects and strong magnetic field which might affect the receiving distance.
5) Set some necessary parameter according to the user’ using situation. When install.

17
Ⅶ, Troubleshoot and solution :
Problems The possible reasons solution
The power light not brighten The battery out of power or
Not connected with the electrical
source
Recover to supply the
electricity or recharge the
battery.
All Wireless signal are invalidation Was disturbed by the same
frequency.
Contact with the dealer.
Can’t be connected with CMS The user’s code or CMS center
number not input or not correct.
Input again.
Signal receiving distance was shorten
The antenna not pull out or close
to the metal
Pull out the antenna,
avoid close to metal.
Some detector launch distance
shorten.
Some detector voltage is low. Change the battery
Ⅶ, technical parameter
(1) Power supply: AC: 185V~245V DC: 12V current: 1500ma
(2) Standby current: ≤ 65ma
(3) Keypad current:≤38ma
(4) Alarming current: <300ma
(5) receiving frequency: 433.92±0.5MHz

18
(6) Preset telephone number: 5 groups
(7) Standby battery: 12V 4.5AH SLA battery
(8) Built-in siren :>85db
(9) Standby time:≥20 hours.
(10) The size of mainframe:
(11) wireless receiving distance: ≥ 150m
(12) defence areas: wireless area 16, wired defence area 8.