7
(Notice:If the system shares a same phone line with your daily-used telephone ,make sure the main
phone line goes in the system first, then you can connect yours telephone to the PHONE OUT
connector. This is to eliminate the possibility of faiture in the telephone which might block the
system to get in touch with you when there is a alarming)
(2) 12V DC:For connection of wired accessories
(3) SPK:For 12V/1A external speaker
LED:For showing the working status of the unit (notice:a current around 4.7k resistor is needed to
be in series connection with the LED lamp)
E.L.:Interface for electronic lock of door entry system. External power supply is needed.
BLU RED:For keypad ,BLU for black,RED for red
YEL GRN:For keypad or other accessories of BUS,YEL for yellow,GRE for green
1—-8 wired zone :for wired protective zones, Each interface needs one 2.2K resistor be connected.
(Zone 1 is for smoke/gas detectors, this zone is always in armed status for safety reason)
四、menu and operation
1. remote controller(Picture 5)
Arm : press the button once, the mainframe will give a short
“Bi” once to enter audio alarm status; press the button again, the
mainframe will sound “BI-BI” twice ,then the system will enter
mute alarm status.
Disarm : when the control panel is alarming, press the button
to stop it.
Panic : No matter what status is the control panel, press this
button once the control panel will alarm immediately.
Stay : Press the button to alter arm or disarm status for different
zones .
Quick entry + , the control panel enters arm status without
any delay.