Homewell Essentials HWEBPM User manual

User Manual
Blood Pressure Monitor HWEBPM
To use the monitor correctly and safely, please read the manual thoroughly.
Thank you very much for selecting Homewell Essentials Blood Pressure
Monitor HWEBPM.
Please keep well this manual in order to reference in future.
Arm Type
/min.
PUL.
homewell
E S SENTIAL S
TMB-995

QUICK REFERENCE
Blood Pressure CategoryBacklight
on BPM
Normal
Prehypertension
High Blood Pressure
(Hypertension) Stage 1
High Blood Pressure
(Hypertension) Stage 2
Hypertensive Crisis
(Consult your doctor immediately)
Systolic
mmHg (upper#)
Diastolic
mmHg (lower#)
less than 120
120-129
130-139
140 or higher
Higher than 180
and
or
or
and/or
less than 80
80-89
90 or higher
Higher than 120
This chart reflects blood pressure categories defined by American Heart Association.
and less than 80
Green
Yellow
Red
Red
Red
/min.
PUL.
START
STOP
START
STOP
Button Button Button
Screen
/min.
PUL.
Off
Mode
/min.
PUL.
Setting
Mode
/min.
PUL.
Working
Mode
/min.
PUL.
Memory
Mode
Quick press: switch
between user 1 and
user 2.
Quick press: show
the previous record.
Long press: delete
the latest record.
Long press: enter
setting mode.
Quick press: confirm
the setting.
Quick press: enter
memory mode.
Quick press: change
the setting
Quick press: show
the next record.
Long press: delete
all the records.
Quick press: turn
off blood pressure
monitor.
Quick press: enter
working mode and
start measuring
blood pressure.
Quick press: turn
off blood pressure
monitor.
Quick press: turn
off blood pressure
monitor.
/ /
Button instuctions

CATALOGUE
1
Table of Contents
INTRODUCTION...................................................................................................................2
General Description
Indications for Use
Contraindications
Measurement Principle
Safety Information
LCD Display Signal
Monitor Components
List
BEFORE YOU START...........................................................................................................9
The Choice of Power Supply
Installing and Replacing the Batteries
Setting Date, Time and Measurement Unit
Select the User
MEASUREMENT.................................................................................................................13
Tie the Cuff
Start the Measurement
DATA MANAGEMENT..........................................................................................................15
Recall the Records
Delete the Records
INFORMATION FOR USER................................................................................................18
Tips for measurement
Maintenances
ABOUT BLOOD PRESSURE..............................................................................................20
What are systolic pressure and diastolic pressure?
What is the standard blood pressure classification?
Irregular heartbeat detector
Why does my blood pressure fluctuate throughout the day?
Why do I get a different blood pressure at home compared to the hospital?
Is the result the same if measuring on the right arm?
TROUBLESHOOTING........................................................................................................22
SPECIFICATIONS...............................................................................................................23
AUTHORIZED COMPONENT ............................................................................................24
CONTACT INFORMATION..................................................................................................24
FCC STATEMENT................................................................................................................24
COMPLIED STANDARDS LIST...........................................................................................25
EMC GUIDANCE.................................................................................................................26
LIMITIED WARRANTY.........................................................................................................31

2
INTRODUCTION
Features:
80*60mm Digital LCD display
Maximum 60 records per each user
Measuring during inflation technology
General Description
Contraindications
Indications for Use
The Homewell Essentials Blood Pressure Monitor is digital monitors intended
for use in measuring blood pressure and heartbeat rate with arm circumference
ranging from 22cm to 42cm(about 8¾˝-16½˝). It is intended for adult indoor use
only.
1.The device should not be used by any person who may be suspected of,
or is pregnant .
2.The device is not suitable for use on patients with implanted,electrical
devices,such as cardiac pacemakers, defibrillators.
Thank you for selecting Homewell Essentials Blood Pressure Monitor
(HWEBPM). The monitor features blood pressure measurement, pulse
rate measurement and the result recording. The design provides you
with two years of reliable service.
Readings taken by the HWEBPM are equivalent to those obtained by
a trained observer using the cuff and stethoscope auscultation method.
This manual contains important safety and care information, and provides
step by step instructions for using the product.
Read the manual thoroughly before using the product.

3
INTRODUCTION
This product uses the Oscillometric Measuring Method to detect blood
pressure.Before every measurement, the unit establishes a “zero point”
equivalent to the atmospheric pressure. Then it starts inflating the cuff.
Meanwhile, the unit detects pressure oscillation generated by beat-to-beat
pulsatile, which is used to deter- mine the systolic pressure and diastolic
pressure as well as pulse rate.
Measurement Principle
The signs below might be in the user manual, labeling or other components.
They are the requirement of standard and using.
Safety Information
The Green Dot is the license
symbol of a European
network of industry-funded
systems for recycling the
packaging materials of
consumer goods.
Symbol for “RECYCLE”
Symbol for “THE OPERATION
GUIDE MUST BE READ”
Symbol for “MANUFACTURER”
Symbol for “SERIAL NUMBER”
Symbol for “TYPE BF APPLIED
PARTS”
Symbol for “DIRECT CURRENT”
Symbol for “ENVIRONMENT
PROTECTION - Electrical waste
products should not be disposed of
with household waste. Please recycle
where facilities exist. Check with your
local authority or retailer for recycling
advice”
Caution: These notes must
be observed to prevent any
damage to the device.
SN
Symbol for “MANUFACTURE
DATE”
!

4
CAUTION
* This device is intended for adult use in homes only.
* The device is not suitable for use on neonatal patients, pregnant women, patients with
implanted, electronical devices, patients with pre-eclampsia, premature ventricular beats, atrial
fibrillation, peripheral, arterial disease and patients undergoing intravascular therapy or
arterio-venous shunt or people who received a mastectomy. Please consult your doctor prior
to using the unit if you suffer from illnesses.
* The device is not suitable for measuring the blood pressure of children. Ask your doctor
before using it on older children.
* The device is not intended for patient transport outside a healthcare facility.
* The device is not intended for public use.
* This device is intended for no-invasive measuring and monitoring of arterial blood pressure.
It is not intended for use on extremities other than the arm or for functions other than obtaining
a blood pressure measurement.
* Do not confuse self-monitoring with self-diagnosis. This unit allows you to monitor your blood
pressure.Do not begin or end medical treatment without asking a physician for treatment
advice.
* If you are taking medication,consult your physician to determine the most appropriate time to
measure your blood pressure. Never change a prescribed medication without consulting your
physician.
* Do not take any therapeutic measures on the basis of a self measurement. Never alter the
dose of a medicine prescribed by a doctor. Consult your doctor if you have any question about
your blood pressure.
* When the device is used to measure patients who have common arrhythmias such as atrial
or ventricular premature beats or atrial fibrillation, the best result may occur with deviation.
Please consult your physician about the result.
* Don't kink the connection tube during use, otherwise, the cuff pressure may continuously
increase which can prevent blood flow and result in harmful injury to the PATIENT.
* When using this device, please pay attention to the following situation which may interrupt
blood flow and influence blood circulation of the patient, thus cause harmful injury to the
patient: connection tubing kinking too frequent and consecutive multiple measurements; the
application of the cuff and its pressurization on any arm where intravascular access or
therapy, or an arterio-venous (A-V) shunt, is present; inflating the cuff on the side of a
mastectomy.
* Warning: Do not apply the cuff over a wound;otherwise it can cause further injury.
*Do not inflate the cuff on the same limb which other monitoring ME equipment is applied
around simultaneously, because this could cause temporary loss of function of those
simultaneously-used monitoring ME equipment.
*On the rare occasion of a fault causing the cuff to remain fully inflated during measurement,
open the cuff immediately. Prolonged high pressure (cuff pressure >300mmHg or constant
pressure >15mmHg for more than 3 minutes) applied to the arm may lead to an ecchymosis.
*Please check that operation of the device does not result in prolonged impairment of patient
blood circulation.
* When measurement, please avoid compression or restriction of the connection tubing.
* The device cannot be used with HF surgical equipment at the same time.
INTRODUCTION

5
CAUTION
* The ACCOMPANYING DOCUMENT shall disclose that the SPHYGMOMANOMETER was
clinically investigated according to the requirements of ISO 81060-2:2013.
* To verify the calibration of the AUTOMATED SPHYGMOMANOMETER, please contact the
manufacturer.
* This device is contraindicated for any female who may be suspected of, or is pregnant.
Besides providing inaccurate readings, the effects of this device on the fetus are unknown.
* Too frequent and consecutive measurements could cause disturbances in blood circulation
and injuries.
* This unit is not suitable for continuous monitoring during medical emergencies or
operations.Otherwise, the patient’s arm and fingers will become anaesthetic, swollen and
even purple due to a lack of blood.
* When not in use, store the device in a dry room and protect it against extreme moisture,
heat, lint, dust and direct sunlight. Never place any heavy objects on the storage case.
* This device may be used only for the purpose described in this booklet. The manufacturer
cannot be held liable for damage caused by incorrect application.
*This device comprises sensitive components and must be treated with caution. Observe the
storage and operating conditions described in this booklet.
* The maximum temperature that the applied part can be achieved is 42.8°C while the
environmental temperature is 40°C.
* The equipment is not AP/APG equipment and not suitable for use in the presence of a
flammable anesthetic mixture with air of with oxygen or nitrous oxide.
* Warning: No servicing/maintenance while the ME equipment is in use.
* The patient is an intended operator.
* The patient can measure, and charge power under normal circumstances and maintain the
device and its accessories according to the user manual.
* To avoid measurement errors, please avoid the condition of strong electromagnetic field
radiated interference signal or electrical fast transient/burst signal.
* The blood pressure monitor, and the cuff are suitable for use within the patient
environment. If you are allergic to polyester, nylon or plastic, please don't use this device.
* During use, the patient will be in contact with the cuff. The materials of the cuff have been
tested and found to comply with requirements of ISO 10993-5:2009 and ISO 10993-10:2010.
It will not cause any potential sensation or irritation reaction.
* Adaptor is specified as a part of ME EQUIPMENT.
* If you experience discomfort during a measurement, such as pain in the arm or other
complaints, press any button to release the air immediately from the cuff. Loosen the cuff
and remove it from your arm.
* If the cuff pressure reaches 40 kPa (300 mmHg), the unit will automatically deflate. Should
the cuff not deflate when pressure reaches 40 kPa (300 mmHg), detach the cuff from the arm
and press any button to stop inflation.
* Before use, make sure the device functions safely and is in proper working condition.
Check the device, do not use the device if it is damaged in any way. The continuous use of a
damaged unit may cause injury, improper results, or serious danger.
* Do not wash the cuff in a washing machine or dishwasher!
INTRODUCTION

6
CAUTION
* The service life of the cuff may vary by the frequency of washing, skin condition, and
storage state. The typical service life is 10000 times.
* It is recommended that the performance should be checked every 2 years and after
maintenance and repair, by retesting at least the requirements in limits of the error of the cuff
pressure indication and air leakage (testing at least at 50mmHg and 200mmHg).
* Please dispose of ACCESSORIES, detachable parts, and the ME EQUIPMENT according
to the local guidelines.
* Manufacturer will make available on request circuit diagrams, component part lists,
descriptions, calibration instructions,etc., to assist to service personnel in parts repair.
* The plug/adapter plug pins insulate the device from the main supply. Do not position the
device in a position where it is difficult to disconnect from the supply mains to safely
terminate operation of ME equipment.
* The operator shall not touch output of batteries /adapter and the patient simultaneously.
* Cleaning :Dust environment may affect the performance of the unit. Please use the soft
cloth to clean the whole unit before and after use. Don’t use any abrasive or volatile
cleaners.
* The device doesn’t need to be calibrated within two years of reliable service.
* If you have any problems with this device, such as setting up, maintaining or using, please
contact the SERVICE PERSONNEL of Huntkey USA Inc..Don’t open or repair the device by
yourself in the event of malfunctions. The device must only be serviced, repaired and opened
by individuals at authorized sales/service centers.
* Please report to Huntkey USA Inc. if any unexpected operation or events occur.
* Keep the unit out of reach of infants, young children or pets to avoid inhalation or
swallowing of small parts. It is dangerous or even fatal.
* Be careful to strangulation due to cables and hoses, particularly due to excessive length.
* At least 30 min required for ME equipment to warm from the minimum storage temperature
between uses until it is ready for intended use. At least 30 min required for ME equipment to
cool from the maximum storage temperature between uses until it is ready for intended use.
* This equipment needs to be installed and put into service in accordance with the
information provided in the ACCOMPANYING DOCUMENTS;
* Wireless communications equipment such as wireless home network devices, mobile
phones, cordless telephones and their base stations, walkie-talkies can affect this equipment
and should be kept at least a distance d away from the equipment. The distance d is
calculated by the MANUFACTURER from the 80MHz to 5.8 GHz column of Table 4 and
Table 9 of IEC 60601-1-2:2014, as appropriate.
* Please use ACCESSORIES and detachable parts specified/ authorised by MANUFAC-
TURE. Otherwise, it may cause damage to the unit or danger to the user/patients.
* There is no luer lock connectors are used in the construction of tubing, there is a possibility
that they might be inadvertently connected to intravascular fluid systems, allowing air to be
pumped into a blood vessel.
* Please use the device under the environment which is provided in the user manual.
Otherwise, the performance and lifetime of the device will be impacted and reduced.
INTRODUCTION

7
INTRODUCTION
LCD Display Signal
SYMBOL DESCRIPTION
Systolic blood pressure High pressure result
Diastolic blood pressure Low pressure result
EXPLANATION
Pulse Pulse/minute
Deflating CUFF air is exhausting of deflating
Current Time Time(year:month:day:hour:minute)
Memory If “MEM” shows, the displayed measurement
values is from the memory.
mmHg Measurement Unit of the blood pressure
Battery Indicator Indicate the current battery
Irregular heartbeat
Irregular heartbeat
Grade
Heartbeat Heartbeat dectetion during measurement
The grade of the blood pressure
User 1
User 2
Start measurement and transmit the results for User 1
Start measurement and transmit the results for User 2
Shocking reminder Shocking will result in inaccurate
/min.
PUL.
/min.
PUL.
kPa Measurement Unit of the blood pressure

8
List
1. Blood Pressure Monitor
(HWEBPM)
3. User manual 4. 4*AA batteries
2. Cuff ( 22~42cm)/ (9-17 inch)
(Type BF applied part)
INTRODUCTION
START
STOP
Component list of
pressure measuring system:
1 Cuff
2 Air pipe
3 PCBA
4 Pump
5 Valve
Monitor Components
BATTERY COMPARTMENT
LCD DISPLAY
AIR HOSE
AIR CONNECTOR PLUG
CUFF
MEM/UP BUTTON
START/STOP BUTTON
SET/DOWN BUTTON
/min.
PUL.
/min.
PUL.

9
The Choice of Power Supply
1.Slide off the battery cover.
2.Install the batteries by matching
the correct polarity, as shown.
3.Replace the cover.
1. Battery powered mode:
6VDC 4*AA batteries
2. AC adaptor powered mode:
6V 1A (Not included)
(Please use the AC adaptor which
authorized by the manufacturer!)
Right picture is the hole in for power
adaptor.
Installing and Replacing the Batteries
Replace the batteries whenever the below happens
The shows
The display dims
The display does not light up
BEFORE YOU START
In order to get the best effect and protect your monitor,please use the
the right batteries and special power adapter which complies with local
safety standard.
CAUTION
CAUTION
Do not use new and used batteries together.
Do not use different types of batteries together.
Do not dispose the batteries in fire. Batteries may explode or leak.
Remove batteries if the device is not likely to be used for some time.
Worn batteries are harmful to the environment. Do not dispose with daily garbage.
Remove the old batteries from the device following your local recycling guidelines.

10
It is important to set the clock before using your blood pressure
monitor, so that a time stamp can be assigned to each record that is
stored in the memory. (year: 2019—2059 time:12 H)
1.When the monitor is
off, hold pressing “
SET ” button for 3
seconds to enter the
mode for year setting.
2.Press the “ MEM ”
button to change the
[YEAR].
3.When you get the right
year, press “ SET ”
button to set down and
turn to next step.
BEFORE YOU START
/min.
PUL.
/min.
PUL.
/min.
PUL.
4.Repeat step 2 and 3 to set the [MONTH] and [DAY].
/min.
PUL.
/min.
PUL.
Setting Date, Time and Measurement Unit

11
5.Repeat step 2 and 3 to set the [HOUR] and [MINUTE].
7.After the [UNIT] is set, the LCD will display “ donE ” then turn
off.
BEFORE YOU START
/min.
PUL.
/min.
PUL.
/min.
PUL.
/min.
PUL.
6.Repeat step 2 and 3 to set the [UNIT] .
/min.
PUL.

12
BEFORE YOU START
1.When the monitor is off , press the “ SET ” button shortly
to enter user setting mode.
Select the User
2.Then press “ SET ” button again, select the user ID between user 1
and user 2 .
3. After selecting the suitable user ID, press “ START/STOP ” button to
save the setteing you have done then the device will turn off.
/min.
PUL.
/min.
PUL.

13
Tie the Cuff
MEASUREMENT
1.
4.
Hold your arm with your palm facing up and tie
the cuff on your upper arm, then position the
tube off-center toward the inner side of arm in
line with the little finger. Or position the artery
mark over the main artery (on the inside of
your arm). Note: Locate the main artery by
pressing with 1 finger approximately 1/2 inch
above the bend of your elbow on the inside of
your left arm. Identify where the pulse can be
felt the strongest. This is your main artery.
The cuff should be snug but not too tight. You
should be able to insert one finger between
the cuff and your arm.
Remove all jewelry, such as watches and
bracelets from your left arm.
Note: If your doctor has diagnosed you with
poor circulation in your left arm, use your
right arm.
Roll or push up your sleeve to expose the
skin. Make sure your sleeve is not too tight.
2.
3.
5. Sit comfortably with your tested arm resting
on a flat surface. Place your elbow on a table
so that the cuff is at the same level as your
heart. Turn your palm upwards. Sit upright in
a chair, and take 5-6 deep breaths.
Rest for 5 minutes before first measurement.
Wait at least 3 minutes between measurements.
This allows your blood circulation to recover.
The patient must relax as much as possible
and do not move and talk during the
measurement procedure.
For a meaningful comparison, try to measure
under similar conditions. For example, take daily
measurements at approximately the same time,
on the same arm, or as directed by a physician.
6.
Take the measurement in a silent room.
The cuff should maintain at the same level
as the right atrium of the heart.
Please sit comfortably. Do not cross your legs
and keep your feet flat on the ground.
Keep your back against the backrest of the
chair.
Helpful tips for Patients, especially for Patients
with Hypertension:
½”

14
1.When the monitor is off, press the
“START/STOP” button to turn on the
monitor, and it will finish the whole
measurement,save and transmit the
measurement data for the desired user.
(Take User 1 for example.)
Start the Measurement
MEASUREMENT
START
STOP
Adjust the zero
LCD display
Inflating and measuring. Display and save the results.
2.Press “START/STOP” button to
power off, otherwise it will turn
off within 1 minute.
Tips:
A.You can press “START/STOP” button at any time to stop measuring
during the process of measurement.
B.Maximum 60 records are both for USER 1 and USER 2.
C.If the measurement result is out of the measurement range (SYS:
60mmHg to 230mmHg; or DIA: 40mmHg to 130mmHg;or Pulse: 40-199
pulse/minute), the LCD will display “out”.
START
STOP
/min.
PUL.
/min.
PUL.
/min.
PUL.
/min.
PUL.

15
DATA MANAGEMENT
Recall the Records
2. Press the “MEM” or “SET” button to rotate the records.
The order of the record, date and time will be displayed alternatively.
The most recent record (1) is shown first. Each new measurement is
assigned to the first (1) record. All other records are pushed back one digit
(e.g., 2 becomes 3, and so on), and the last record (60) is dropped from the
list.
CAUTION
1.When the monitor is off, please press “MEM” button to show the average
value of the latest three records.If the records are less than 3 groups, it will
display the latest record instead. Displays different colors at different levels
when the monitor is under the memory recall mode.
(Take user 1 for example.)
The current is
the No. 1.Twenty
records in total.
The corresponding
time is A.M.9:00.
The corresponding
date is July 30th.
/min.
PUL.
/min.
PUL.
/min.
PUL.
/min.
PUL.

16
DATA MANAGEMENT
1.Hold pressing “MEM” button for 3 seconds when the monitor is in the
memory recall mode. The LCD will display “Use ID + dEL ALL”.
If you did not get the correct measurement, you can delete all
results of the selected user by following steps below .
Delete the Records
2.Press “MEM” button to confirm deleting, the LCD will display “Use ID +
dEL donE” and the monitor will turn off.
/min.
PUL.
/min.
PUL.

17
DATA MANAGEMENT
5.If you don’t want to delete the records, press the “START/STOP” button,
it will turn off and quit the deletion. Or when it is in the deleting memory
mode, it will turn off and quit the deletion if there is no operation in one
minute.
6. If there is no record, the LCD will display as below :
3.Hold pressing “SET” button for 3 seconds when the monitor is in the memory
recall mode (excluding the LCD displays AVG). The LCD will blink “Use ID +
dEL ONE”.
4.Press “MEM” button to confirm deleting selected record, the LCD will
display “Use ID + dEL donE” and the monitor will turn off.
/min.
PUL.
/min.
PUL.
/min.
PUL.

18
Tips for Measurement
Wait at least 1 hour after
dinner or drinking
Wait at least 20 minutes
after taking a bath
Do not take measurement
in a cold environment
Do not take immediate measurement
after tea, coffee or smoking
Do not take measurement when
talking or moving your fingers
Do not take measurement when
you want to discharge urine
Measurements may be inaccurate if taken in the following
circumstances.
INFORMATION FOR USER
Table of contents