manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Honeywell Home
  6. •
  7. Receiver
  8. •
  9. Honeywell Home resideo EW535M0131 Manual

Honeywell Home resideo EW535M0131 Manual

Popular Receiver manuals by other brands

Televes ZAS HD SAT user manual

Televes

Televes ZAS HD SAT user manual

Realistic DX-75 Operating and service instructions

Realistic

Realistic DX-75 Operating and service instructions

Saris 4620 Assembly instructions

Saris

Saris 4620 Assembly instructions

Mini DTR 206C PVR user manual

Mini

Mini DTR 206C PVR user manual

RF Elements TwistPort manual

RF Elements

RF Elements TwistPort manual

Denon DN-200WS user guide

Denon

Denon DN-200WS user guide

Yamaha RX-V467 owner's manual

Yamaha

Yamaha RX-V467 owner's manual

Russound SaphIR 858 instruction manual

Russound

Russound SaphIR 858 instruction manual

Quasonix RDMS Firmware update procedure

Quasonix

Quasonix RDMS Firmware update procedure

Pioneer XV-HTD1 Service manual

Pioneer

Pioneer XV-HTD1 Service manual

ATZ HDMI-V2-44HE150 manual

ATZ

ATZ HDMI-V2-44HE150 manual

Sony XNV-770BT MyTomTom Specifications

Sony

Sony XNV-770BT MyTomTom Specifications

Grundig STR 7122 TWIN Service manual

Grundig

Grundig STR 7122 TWIN Service manual

Creative Blaster Modem user guide

Creative

Creative Blaster Modem user guide

Panduit ATLONA AT-OME-RX11 installation guide

Panduit

Panduit ATLONA AT-OME-RX11 installation guide

VOLTCRAFT UTPS-40 operating instructions

VOLTCRAFT

VOLTCRAFT UTPS-40 operating instructions

JVC KW-ADV794 instructions

JVC

JVC KW-ADV794 instructions

Litelink VT-1001 operating instructions

Litelink

Litelink VT-1001 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

IzarCenter
EW535M0131 M-Bus Receiver
Installation and Setup Instructions
Figure 1. Installation
Figure 2. Configuration example
Important Note: The M-Bus Receiver device may only be installed and operated by electrically quali-
fied personnel. For the installation appropriate preventive measures against ESD have
to be undertaken. For installations, please ensure that – depending on cable length
(resistance and impedance) the M-Bus voltage for operating the M-Bus Receiveris
never below 32V.
1 Mounting and Dismounting
For easy installation the EW535M0131 M-Bus Receiver (abbr.: Receiver) has a removable wall holder.
Receiver must be installed at least 10cm away from metal parts (e.g. pipes or wires). Installation area must
comply with housing protection class of IP20.
Wall holder: Wall holder is fixed with two 5 mm screws on a smooth and even surface. Drill appropriate holes
with spacing of 80mm (see Figure 1).
Mounting: Place Receiver onto wall holder as shown in right hand figure (B1). Slide Reveiver onto wall
holder (B2) until lock (B3) snaps in. Slide terminal protection cap from bottom of opening up-
wards to cover terminals (B4) (mandatory). Bolt terminal protection cap with a plastic seal (B5).
Resideo Technologies, Inc. •Subject to change MU1H-1060GE25 R1020 (A)
EW535M0131 M-Bus Receiver
Installation and Setup Instructions
Dismounting: Use screwdriver to turn plastic seal until it breaks (A1). Slide terminal protection cap downwards
to uncover terminals (A2). Lift lock (A3) and slide Receiver upwards (A4). Receiver can now be
removed from wall holder.
2
Electrical Connections
For connecting Receiver terminal protection cap must be removed.
Connections: Connect two wire cable from an IzarCenter to
terminals 1 and 2 (M-Bus input). Connection is
polarity independent. If you want to connect addi-
tional Receivers or standard M-Bus devices to
same M-Bus, use terminals 3 and 4 (M-Bus out-
put) to extend M-Bus to next device.
3
Application
The Receiver can only be used with IzarCenter 60 / 120 / 250. It cannot be used with HydroCenter 25. The Re-
ceiver consumes M-Bus currency comparable to 20 standard M-Bus devices. Therefore, it is possible to connect:
max. 3 Receivers to an IzarCenter 60 (EW535M5777 or EW535M5781)
max. 6 Receivers to an IzarCenter 120 (EW535M5778 or EW535M5782)
max. 12 Receivers to an IzarCenter 250 (EW535M5780 or EW535M5783)
In all cases maximum M-Bus cable length is limited to 100m...1km (max.), dependent on number of Receivers
and of other M-Bus devices connected to the M-Bus.
4
Indicators
A red and a green LED next to terminals of Receiver indicate operational state.
Startup: Red LED lights up once for less than 3 seconds
Operation: Green LED lights up if valid radio device telegram has been received
Hardware failure: Red LED lights up permanently after startup. In this case self check has failed and Receiver
must be replaced
Firmware update: During firmware update of Receiver both LEDs flash in parallel with a frequency of approxi-
mately 1Hz
5
Technical Data
Power supply: Via M-Bus, U = 32…42V, Imax = 30mA (20 M-Bus loads)
Housing: 120 x 120 x 35mm, plastic housing for wall mounting (internal antenna)
Protection class: IP20
Operating temp.: 0…60°C
Humidity: 10…70% relative humidity, non condensing
Weight: approx. 0.2kg
Software: IzarCenter, please use latest version. Software can be downloaded free of charge from
homecomfort.resideo.com
Terminal Description
1 M-Bus input polarity 1
2 M-Bus input polarity 2
3 M-Bus output polarity 1
4 M-Bus output polarity 2
Resideo Technologies, Inc. •Subject to change MU1H-1060GE25 R1020 (A)
www.resideo.com
Ademco 1 GmbH
Hardhofweg 40
74821 Mosbach
Phone: +49 1801 466 388
info.de@resideo.com
homecomfort.resideo.com
@2020 Resideo Technologies, Inc. All
rights reserved. The Honeywell Home
trademark is used under license from
Honeywell International Inc. This product
is manufactured by Resideo