Honeywell IN-S Series User manual

Honeywell
730xxxxxx ©
Elster GmbH | All rights reserved. Subje t to modifi ation
1
English
Instruction Manual
Pulse generator
Type IN-Sxx / S1xRx / S2xRx / QA E1 / RVG-ST E1
Betriebsanleitung
Impulsgeber
Typ IN-Sxx / S1xRx / S2xRx / QA E1 / RVG-ST E1
Mode d’emploi
Émetteur d’impulsions
Type IN-Sxx / S1xRx / S2xRx / QA E1 / RVG-ST E1
Manual de instrucciones
Emisor de impulsos
Modelos IN-Sxx / S1xRx / S2xRx / QA E1 / RVG-ST E1
Istruzioni d’uso
Trasmettitore d’impulsi
Tipo IN-Sxx / S1xRx / S2xRx / QA E1 / RVG-ST E1
Gebruiksaanwijzing
Impulsgever
Type IN-Sxx / S1xRx / S2xRx / QA E1 / RVG-ST E1

Honeywell
2
730xxxxxx © Elster GmbH | All rights reserved. Subje t to modifi ation

Honeywell
730xxxxxx ©
Elster GmbH | All rights reserved. Subje t to modifi ation
3
English
Français
Español
Italiano Nederlands Deuts h
Instruction Manual
Pulse generator
Type IN-Sxx / S1xRx / S2xRx / QA E1 / RVG-ST E1
Betriebsanleitung
Impulsgeber
Typ IN-Sxx / S1xRx / S2xRx / QA E1 / RVG-ST E1
Mode d’emploi
Émetteur d’impulsions
Type IN-Sxx / S1xRx / S2xRx / QA E1 / RVG-ST E1
Manual de instrucciones
Emisor de impulsos
Modelos IN-Sxx / S1xRx / S2xRx / QA E1 / RVG-ST E1
Istruzioni d’uso
Trasmettitore d’impulsi
Tipo IN-Sxx / S1xRx / S2xRx / QA E1 / RVG-ST E1
Gebruiksaanwijzing
Impulsgever
Type IN-Sxx / S1xRx / S2xRx / QA E1 / RVG-ST E1

Honeywell
4
730xxxxxx © Elster GmbH | All rights reserved. Subje t to modifi ation

Honeywell
73024353
© Elster GmbH | All rights reserved. Subje t to modifi ation
5
English
I -Sxx
S1xRx
S2xRx
QA E1
RVG-ST E1
Instruction manual
Pulse generator
Type IN-Sxx / S1xRx / S2xRx / QA E1 / RVG-ST E1


Honeywell
73024353
© Elster GmbH | All rights reserved. Subje t to modifi ation
7
English
Contents
1. Safety instructions ................................................................................................ 9
1.1 Intended use ................................................................................................... 10
1.2 Approvals and certifications ........................................................................... 10
1.3 Copyright and data protection ....................................................................... 11
1.4 Exemption from lia ility ................................................................................. 11
1.5 Product lia ility and guarantee ...................................................................... 12
1.6 Personnel ........................................................................................................ 12
1.7 Intended use and field of application ............................................................. 12
1.8 Legal declarations ........................................................................................... 12
1.9 Recycling and environmental protection ....................................................... 12
2. Structure and function ........................................................................................ 13
2.1 Device description .......................................................................................... 13
2.2 Connection configurations ............................................................................. 13
3. Installation and commissioning ........................................................................... 15
4. Storage................................................................................................................ 16
5. Cleaning .............................................................................................................. 16
6. Repair ................................................................................................................. 16
7. echnical data ..................................................................................................... 16
8. Ambient conditions ............................................................................................. 17
9. Approvals ............................................................................................................ 17
10. Annex A – Standards and Norms ....................................................................... 18

Honeywell
8
73024353 © Elster GmbH | All rights reserved. Subje t to modifi ation
Information on the documentation
The latest version of the operating instru tions is available to download from the
Honeywell website.
Please read the information in this do ument arefully in order to avoid injury to
the user or damage to the devi e. Moreover, urrently valid national standards,
safety regulations and a ident prevention regulations must be adhered to.
Should you have any problems understanding the ontents of this do ument,
please onta t your lo al Honeywell bran h for support. Honeywell annot
a ept any responsibility for damage to property or personal injuries whi h are a
result of the information in this do ument not having been understood properly.
This do ument helps you to set up the operating onditions in su h a way that
the safe and effi ient use of the devi e is assured. In addition, this do ument also
spe ifies points and safety measures whi h must be parti ularly observed and
whi h are indi ated using the following symbols:
WARNING or CAUTION
This symbol warns of dangerous situations. Failure to follow the
instructions could result in danger to people and the
environment or the meter could suffer damage.
INFORMATION or NOTE
Accurate measurement cannot be ensured if information or
notes with this symbol are ignored.

Honeywell
73024353
© Elster GmbH | All rights reserved. Subje t to modifi ation
9
English
1. Safety instructions
WARNING!
Danger of electrostatic discharge – only use a damp cloth to clean.
WARNING!
If there is danger that the device can be damaged from falling
(pointed, sharp edged or heavy) objects, the operator must protect
the device.
WARNING!
Exposure to danger which can result from a chemical reaction
between parts of the meter and chemical substances in the vicinity
must be discussed with the manufacturer and the cause must be
eliminated.
WARNING!
The gas meter on/in which the pulse generator is installed must be
integrated into the equipotential bond, e.g. by connecting it to the
grounded pipeline.
INFORMATION!
Compliance with the specified operating and ambient conditions
as indicated on the type label and the gas meter type label is
absolutely essential for the safe operation of the pulse generator.

Honeywell
10
73024353 © Elster GmbH | All rights reserved. Subje t to modifi ation
1.1 Intended use
INFORMATION!
The manufacturer shall not be liable for damage caused by
improper or inappropriate use.
1.2 Approvals and certifications
CE marking / EU declaration of conformity
The manufa turer ertifies onformity with the EU
de laration of onformity and by atta hing the CE marking.
The pulse generator meets the statutory requirements of
the relevant EU guidelines.
Comprehensive information on the appli able EU
guidelines and standards, as well as re ognized
ertifi ations, is ontained in the EU de laration of
onformity.
The EU de laration of onformity is in luded in the delivery
and is also available to download at www.do uthek. om.
See Chapter 9 for more approvals and Directives.
Approvals and Annex A – Standards and orms
ATEX/IECEx
DANGER!
The pulse generator is suitable for use in Zone 1 hazardous
areas and is approved with the following certification:
2G Ex ia IIC T4 Gb
2G Ex ib IIC T4 Gb
IECEx TUR 16.0032X (IECEx)
TÜV 16 ATEX 7729 X (ATEX)
TÜV Rheinland Industrieservi e GmbH
Am Grauen Stein | 51105 Köln | Germany
TÜV Rheinland Industrieservi e GmbH
Am Grauen Stein | 51105 Köln | Germany

Honeywell
73024353
© Elster GmbH | All rights reserved. Subje t to modifi ation
11
English
1.3 Copyright and data protection
This do ument has been reated with the greatest possible are. No liability
is assumed for the a ura y, ompleteness or urren y of the ontents.
The ontents and works produ ed in this do ument are subje t to opyright.
Contributions by third parties are identified as su h. The reprodu tion,
pro essing, distribution and any form of use beyond that whi h is permitted
by opyright require the written authorization of the respe tive author or the
manufa turer. The manufa turer strives to always respe t the opyright of
others or to use his own or li en e-free works.
We would like to point out that data transfer via the Internet (e.g. through e-
mail ommuni ation) an be subje t to brea hes in se urity. It is not
possible to provide omplete prote tion against a ess by third parties.
1.4 Exemption from liability
The manufa turer shall not be liable for damage of any type aused by the
use of this produ t, in luding but not restri ted to, dire t, indire t or
in idental damage and its onsequen es.
This exemption from liability does not apply if the manufa turer has a ted
intentionally or with gross negligen e. In the event that any appli able law
does not allow su h restri tions on implied warranties for defe ts, or the
ex lusion or limitation of ertain payments for damages, and should su h
law apply to you, the above-mentioned exemption from liability, ex lusions
or limitations may not apply to you in part or in whole.
For every produ t pur hased, the warranty is valid in a ordan e with the
orresponding produ t do umentation as well as the onditions of sale and
delivery of the manufa turer.
The manufa turer reserves the right to amend without prior noti e the
ontents of the do uments, in luding this exemption from liability, in any
form and at any point in time, and for any reason, and shall in no way be liable
for any possible onsequen es of su h amendments.

Honeywell
12
73024353 © Elster GmbH | All rights reserved. Subje t to modifi ation
1.5 Product liability and guarantee
The responsibility as to whether the devi e is suitable for the intended use is
that of the operator. The manufa turer annot a ept any liability for the
onsequen es of misuse by the operator. Improper installation or operation
of the devi es (systems) render the warranty void. Furthermore, the relevant
“General Terms and Conditions” whi h form the basis of the pur hase
ontra t also apply.
1.6 Personnel
This manual is aimed at staff who have adequate spe ialist and te hni al
knowledge (in Germany, for instan e, in a ordan e with DVGW Codes of
Pra ti e 492 and 495 or omparable te hni al regulations) on the basis of
their training and experien e in the se tor of energy and gas distribution.
1.7 Intended use and field of application
This produ t is intended to be used for the installation on/in gas meters
from Elster/Honeywell
This produ t is not intended to be used for the installation on/in gas meters
from other manufa turers.
1.8 Legal declarations
The metrologi al onformity assessment is based on the regulations of the
ountry on erned, where the devi e will be used.
1.9 Recycling and environmental protection
Honeywell has designed the transport pa kaging of the devi e to be
environmentally friendly. Pa kaging materials are always sele ted
onsistently with a view to re y ling. The ardboard items used onstitute
se ondary raw materials for the paperboard and paper industry. The
Instapak® foam pa kaging is re y lable and an be reused.
Plasti sheeting and strips/bands are also made of re y lable plasti . At
Honeywell, subsequent re y ling and disposal are already elements of the
produ t development pro ess. When sele ting the materials, we allow for
reusability of the materials, suitability of materials and subassemblies for
dismantling and separation, and the risks of environmental pollution and
health risks when re y ling and dumping on landfill sites.

Honeywell
73024353
© Elster GmbH | All rights reserved. Subje t to modifi ation
13
English
2. Structure and function
The produ ts IN-Sxx / S1xRx / S2xRx / QA E1 / RVG-ST E1 are low-frequen y
pulse generators for turbine and rotary gas meters from Elster/Honeywell.
The versions IN-Sxx an be atta hed to the index from the outside. The
versions S1xRx / S2xRx / QA E1 / RVG-ST E1 are integrated in the index.
2.1 Device description
The pulse generators onsist of one series onne tion per hannel
omprising a reed swit h and a resistor. The reed swit h is driven by a
magnet whi h is lo ated on the inside of the gas meter index. The rotation of
the magnet usually orresponds to the rotation of the last digit roller of the
me hani al index.
When the magnet triggers the reed swit h, the atta hed ele tri al ir uit is
losed. A losure orresponds to one pulse.
2.2 Connection configurations
Type Version Terminals
IN-S10
IN-S10K
IN-S10V
6- ore able
E1 = brown (+) / white (-)
E2 = green (+) / yellow (-)
PCM = grey (+) / pink (-)
IN-S10A 4- ore able E1 = brown (+) / white (-)
PCM = green (+) / yellow (-)
IN-S11
S1xR3
S2xR3
RVG-ST 2xE1
6-pin plug
E1 = 1(+) / 2(-)
E2 = 5(+) / 6(-)
PCM = 3(+) / 4(-)
IN-S11F 6-pin plug
BF = 4(+) / 6(-)
BF = 3(+) / 5(-)
PCM = 1(+) / 2(-)

Honeywell
14
73024353 © Elster GmbH | All rights reserved. Subje t to modifi ation
S1xR
S2xR 6-pin plug
E1 = 1(+) / 2(-)
IN-S12
Two 6-pin plugs
Plug 1
E1 = 1(+) / 2(-)
Plug 2
E2 = 1(+) / 2(-)
PCM = 3(+) / 4(-)
IN-S12F
Two 6-pin plugs
Plug 1
BF = 4(+) / 6(-)
PCM = 1(+) / 2(-)
Plug 2
BF = 3(+) / 5(-)
IN-S15 6-pin plug
E1 = 1(+) / 4(-)
E2 = 2(+) / 5(-)
PCM = 3(+) / 6 (-)
QA E1 3-pin plug
E1 = 1(+) / 4(-)

Honeywell
73024353
© Elster GmbH | All rights reserved. Subje t to modifi ation
15
English
IN-S22
Two 3-pin plugs
Plug 1
E1 = pin A(+) + B(-)
E2 = pin C(+) + B(-)
Plug 2
E1 = pin A(+) + B(-)
E2 = pin C(+) + B(-)
Table 1 | Terminal assignment
3. Installation and commissioning
The pulse generator versions IN-Sxx are inserted sideways into the
mounting of the index until they li k into pla e (see Fig. 1).
The pulse generators S1xRx / S2xRx / QA E1 / RVG-ST E1 are supplied
ready for operation together with the gas meters.
The ables are to be onne ted as per Table 1, Terminal assignment.
For onne ting the devi es, use a s reened able pursuant to
IEC EN 60079-14.
WARNING!
If the pulse generators are used in hazardous areas, they have to be
connected to intrinsically safe circuits.
Safety barriers must be equipped for ignition protection rating
Ex ib IIC or Ex ia IIC.
Fig. 1 | Installation of IN-Sxx

Honeywell
16
73024353 © Elster GmbH | All rights reserved. Subje t to modifi ation
4. Storage
Store the devi e in a dry and dust-free lo ation.
Avoid onstant dire t sunlight.
Store the devi e in its original pa kaging.
Storage temperature: -40 to +70°C / -40 to +158°F.
5. Cleaning
WARNING!
Danger of electrostatic discharge – only use a damp cloth to clean.
DANGER!
There is a risk of explosion if the plastic cover of the index is
cleaned with a dry cloth.
It is forbidden to use aggressive chemical cleaning agents or
solvents for cleaning.
6. Repair
INFORMATION!
Repairs may be carried out only by authorized workshops.
7. Technical data
Ui
≤ 24 V
Ii
≤ 25 mA
Pi
≤ 0.25 W
Ci
= 0 F
Li
= 0 H
Table 2 | Te hni al data

Honeywell
73024353
© Elster GmbH | All rights reserved. Subje t to modifi ation
17
English
8. Ambient conditions
Ambient temperature
-
40°C to
+70°C
Storage temperature
-
40°C to +70°C
Humidity
0 to 80% RH
Max. height above sea level
2000 m
Outdoor installation
Yes
Me hani al environments
M1
Installation ategory a ording to
CAN/CSA
1
Table 3 | Ambient onditions
9. Approvals
Approval:
A
pproval number:
Approval body:
CSA
CSA 17CA70097478
CSA Group | 178 Rexdale Boulevard
Toronto, ON M9W 1R3
ATEX
II 2G Ex ia IIC T4 Gb
II 2G Ex ib IIC T4 Gb
TÜV 16 ATEX 7729 X
TÜV Rheinland Industrieservi e GmbH
Am Grauen Stein | 51105 Köln | Germany
IECEx
Ex ia IIC T4 Gb
Ex ib IIC T4 Gb
IECEx TUR 16.0032X
TÜV Rheinland Industrieservi e GmbH
Am Grauen Stein | 51105 Köln | Germany
Table 4 | Approvals
ATEX/IECEx legend:
Marking of explosion prote tion
II Equipment group: industrial (mining ex luded)
2 Equipment ategory 2 (Zone 1)
G Potentially explosive gas atmospheres
ia/ib Type of ignition prote tion: intrinsi ally safe
IIC Explosion group for gases
T4 Temperature lass
Gb Equipment prote tion level

Honeywell
18
73024353 © Elster GmbH | All rights reserved. Subje t to modifi ation
10. Annex A – Standards and orms
The pulse generators meet the following norms and standards or the
relevant hapters within them*.
2014/32/EU
–
Annex
IV (MI
-
001),
Annex VII (MI-005) Measuring Instruments Dire tive (MID)
DIN EN 12480:
2015
Gas meters
–
R
otary
displa ement
gas meters
DIN EN 12261:2002 +
A1:2006
Gas
meters
–
T
urbine gas meters
DIN EN 60079
-
0:2012
+ A11:2013
IEC 60079-0:2011
CAN/CSA-C22.2 NO. 60079-0:15
Explosive atmospheres – Part 0: Equipment –
General requirements
DIN EN 60079
-
11:2012
IEC 60079-11:2011
CAN/CSA-C22.2 NO. 60079-11:14
Explosive atmospheres
Part 11: Equipment prote tion by intrinsi safety
“i”
CAN/CSA
-
C22.2 NO. 0
-
10
General requirements
–
Canadian ele tri al ode,
part II
CAN/CSA
-
C22.2 NO. 61010
-
1
-
12
Safety requirements for ele tri al
equipment for measurement, ontrol and
laboratory use – Part 1: General requirements –
Third edition
* Standards valid at the time of the operating instru tions going to press.

Honeywell
73024353
© Elster GmbH | All rights reserved. Subje t to modifi ation
19
English

This manual suits for next models
4
Table of contents
Languages: