Product Information OMNI-C-RRI
Counter OMNI-C-RRI
●Flow measurement with integrated totaliser
●Can be used as dosing counter with programmable
end signal
●No magnets uses inductive sensor
●Long working life thanks to high quality ceramic axis and
special plastic bearing
●Modular construction with various connection systems
●Rotatable electronic housing for best reading position
●Designed for industrial use
●Small, compact construction
●Simple installation
●Optionally, non-return valve, filter, constant flow rate devi-
ce in the connections
Characteristics
The flow meter consists of a spinner which is rotated by the flowing
medium. The rotor's rotational speed is proportional to the flow
volume per unit time. The rotor is fitted with stainless steel clamps
(optionally titanium or Hastelloy®). An inductive proximity switch
records the rotational speed, which is proportional to the flow rate.
The totaliser of the OMNI flow rate system enables a totalisation or
measurement of consumption for all HONSBERG device families
(for fluids and gases) with which the OMNI system is compatible;
this is independent of the input signal, pulse or analog input, and of
the measurement process.
Simple filling control is also possible. Here, the counter can be set
to count upwards or downwards.
When the preset point is reached, a switching signal is emitted
which is available in antivalent form to two outputs.
Resetting can be carried out by means of a signal input or also by a
programming ring.
The state of the counter is indicated in an LCD display with only
four digits. Here, the number of decimal places and the unit
displayed is continuously matched to the current state of the
counter. In this case, the smallest value which can be displayed is
0.00 ml (= µl), and the largest is 9999 m³. The counter therefore
has 3 places, of which the four most significant are displayed at
any one time. The display resolution at all times is therefore at least
per thousand of the displayed value, or better, and this generally
exceeds the accuracy of the connected flow transmitter. The
non-displayed digits of the counter are in that case irrelevant to the
accuracy of the measurement.
The automatic dynamic changeover of units in the display in
relation to the state of the counter makes the value easy to read in
spite of a display with only four digits. In addition, user configuration
of the counter is unnecessary.
In addition to the totalised value, the present flow rate can be
displayed.
The stainless steel case has a hardened non-scratch mineral glass
pane. It is operated by a programming ring fitted with a magnet, so
there is no need to open the operating controls housing, and its
leakproofness is permanently ensured.
By turning the ring to right or left, it is simple to modify the
parameters (e.g. switching point, hysteresis...). To protect from
unintended programming, it can be removed, turned through 80 °
and replaced, or completely removed, thus acting as a key.
Technical data
Sensor inductive
Nominal width DN 0 (OMNI-C-RRI-0 0)
DN 25 (OMNI-C-RRI-025)
Mechanical
Connection
female thread G 3/8, G
male thread G 3/8 A, G A
hose nozzle Ø , Ø30
(other threaded, crimped, and plug-in
connections, connections with constant flow
rate device or limiters available on request)
Metering ranges 0. .. 00 l/min
for details, see table "Ranges"
Measurement
accuracy
±3 % of the measured value
Repeatability ± % of full scale value
Pressure loss max. 0.5 bar
Pressure
resistance
PN 6 bar
Medium
temperature
0..60 °C
Storage
temperature
-20..+80 °C
Materials
medium-contact
Housing PPS
(Fortron 40L4)
Rotor PVDF
Clamps .43 0
optionally:
titanium or
Hastelloy®
Bearing Iglidur X
Axis Ceramic Zr02-TZP
Seal FKM
Materials, non-
medium-contact
Clamps .430
Electronic adapter CW6 4N nickelled
Electronics housing stainless steel
.4305
Glass mineral glass, har-
dened
Magnet samarium-Cobalt
Ring POM
Supply voltage 8..30 V DC
Power
consumption
< W
Counter range 0.000 ml to 9999 m³
with automatic setting of the decimal places
and of the applicable unit.
pi-ho-fro-omni-c-rri_e V .0 -0

Honsberg Instruments GmbH
Tenter Weg 2-8 ● 42897 Remscheid ● Germany
Fon +49 (0) 2 9 - 9672 - 0 ● Fax - 40
www.honsberg.com ● [email protected]
Product Information OMNI-C-RRI
Switching signal
outputs
(Pin 4 + 5)
2 x push-pull output, max. 00 mA, resistant
to short circuits, and reversed polarity
protected
antivalent states, configurable on the device
as a wiper signal or edge signal
Counter reset
signal
(Pin 2)
input 8..30 V resistant to short circuits and
polarity reversal
PIN 2, wiper signal, positive or negative
edge can be selected locally
Counting input (normally not directly accessible from the
device) Frequency input 0.. 0 kHz
analog input 0/4..20 mA
analog input 0.. 0 V
Display backlit graphical LCD-Display
(transreflective), extended temperature
range -20..+70 °C, 32 x 6 pixels,
background illumination, displays value and
unit, flashing LED signal lamp with
simultaneous message on the display.
Electrical
connection
for round plug connector M 2x , 5-pole
Ingress protection IP 67 / (IP 68 when oil-filled)
Weight OMNI-C-RRI-0 0 approx. 0.4 kg
OMNI-C-RRI-025 approx. 0.7 kg
Conformity CE
Ranges
Metering range Types Qmax
l/min (H2O) l/min (H2O)
0. .. .5 OMNI-C-RRI-0 0...020 .8
0.2.. 0.0 OMNI-C-RRI-0 0...050 2.0
0.4.. 2.0 OMNI-C-RRI-0 0..0.070 4.4
2.0.. 30.0 OMNI-C-RRI-025...080 36.0
3.0.. 60.0 OMNI-C-RRI-025..0. 20 72.0
4.0.. 00.0 OMNI-C-RRI-025..0. 60 20.0
The measured values were determined with horizontal flow (OMNI
electronics upwards) using water at 25 °C.
Wiring
Before the electrical installation, it must be ensured that the supply
voltage corresponds to the data sheet.
The use of shielded cabling is recommended.
Dimensions
Threaded connection
G DN Types H/L L1 B C E X SW
G 3/8 0 RRI-0 0G 50 84 29 2.5 6.5 2 22
G 3/8 A RRI-0 0A 4
G 25 RRI-025G 70 0 53 23.0 27.5 8 38
G A RRI-025A 22
Hose nozzle connection
D DN Types H/L L1 B C E X
Ø 0 RRI-0 0T 50 96 29 2.5 6.5 2
Ø30 25 RRI-025T 70 76 53 23.0 27.5 45
Gooseneck option
Handling and operation
Installation
The Rototron device is installed in the pipework with the aid of the
rotatable adapter pieces. If necessary, the adapters can be
removed from the body of the housing after the stainless steel clips
have been removed from the housing. Before reinstalling, it should
be ensured that both the adapter with the O-ring and the sealing
surface in the body are clean and undamaged. The adapters
should be fitted carefully in the housing (it is best to turn them), so
that the O-ring is not damaged.
With this flow sensor, there is no need for run-in and run-out
sections. However, it should be ensured that the flow sensor is at
all times filled with medium. Any preferred installation position is
possible, but the best possible venting position should be chosen
(rotor axis horizontal, flow horizontal or from bottom to top).
Air bubbles affect the measurement results. For filling processes,
the valve should be installed behind the sensor. A running up time
of approx. 0.5 seconds and a running down time of approx. 3
seconds should be noted.
2 pi-ho-fro-omni-c-rri_e V .0 -0
A gooseneck (optional) between
the electronics head and the
primary sensor provides
freedom in the orientation of the
sensor. This option
simultaneously provides thermal
decoupling between the two
units.
Z Z
2
3
4
5
brown
white
blue
black
grey
8..30 V DC
reset input
0 V
switching signal
switching signal 2
PNP NPNConnection example:
43
25
Z = Load

Honsberg Instruments GmbH
Tenter Weg 2-8 ● 42897 Remscheid ● Germany
Fon +49 (0) 2 9 - 9672 - 0 ● Fax - 40
www.honsberg.com ● [email protected]
Product Information OMNI-C-RRI
Programming
On the display, the counter indicates the state of the totaliser as a
value and unit. The units ml, L, m3 are set automatically.
For operation as a totaliser, no configuration by the user is
necessary.
To use the other functions, configuration may be required. This is
carried out using the programming ring located on the device.
The annular gap of the programming ring can be turned to positions
and 2. The following actions are possible:
Set to 1 = continue (STEP)
Set to 2 = modify (PROG)
Neutral position between
1 and 2
The ring can be removed to act as a key, or turned through 80 °
and replaced to create a programming protector.
Operation is by dialog with the display messages, which makes its
use very simple.
The control display of the present flow rate depends on the
metering range of the selected flow transmitter, and has already
been set appropriately in the factory (ml/min, l/min, l/h, m3/h).
It is activated by turning the ring to position
After 0 seconds, the display automatically returns to the totaliser
mode.
For operation as a preset counter, the following must be set:
. The preset point
2. The type of output signal ("Preset has been reached"):
Signal edge / wiper pulse
width of the wiper pulse, if required
3. The unit of the preset point:
(ml, litre, m3).
Starting from the normal display (total and unit), if (STEP) is
selected repeatedly, then the counter shows the following
information:
●Normal display is total and unit (e.g. litre)
●Display of present value (e.g. l/min)
●Preset point incl. type of switching output.
●Code
The code gives access to various input levels into which
parameters can be entered (so that this does not occur
unintendedly, the code must be entered!)
Code 111:
●Gate time (available only for sensors which transmit frequency)
●Filter time
●Direction of count (pos. / neg.)
●Unit for switching value/reset point
●Decimal place for switching value/reset point
●Switching type for switching value (edge/wiper signal)
●Pulse duration (for wiper signal)
●Reset method (manual / via signal)
Code 100:
●Manual reset for totaliser
The detailed flow chart for operation is available in the "Operating
instructions for OMNI-C".
pi-ho-fro-omni-c-rri_e V .0 -0
3

Honsberg Instruments GmbH
Tenter Weg 2-8 ● 42897 Remscheid ● Germany
Fon +49 (0) 2 9 - 9672 - 0 ● Fax - 40
www.honsberg.com ● [email protected]
Product Information OMNI-C-RRI
Ordering code
The basic device is ordered e.g. RRI-0 0...
with electronics z.B. OMNI-C-RRI-0 0...
. 2. 3. 4. 5. 6. 7. 8. 9.
RRI- E
0. . 2. 3.
OMNI-C-RRI A S
m=Option
1. Nominal width
0 0 DN 0
025 DN 25
2. Mechanical connection
G female thread
A male thread
T hose nozzle
3. Connection material
V PVDF
MmCW6 4N nickelled
Km.4305
4. Housing material
Q PPS
V PVDF
AmPPS with transparent cover PSU
5. Inwards flow drilling
020 Ø 2.0 l
050 Ø 5.0 l
070 Ø 7.0 l
080 Ø 8.0 l
20 Ø 2.0 l
60 Ø 6.0 l
6. Seal material
V FKM
EmEPDM
NmNBR
7. Rotor
0 with 0 clamps
02 mwith 2 clamps
05 mwith 5 clamps
8. Material for clamps
K .43 0
Tmtitanium
HmHastelloy®
9. Connection for
E electronics
10. For nominal width
0 0 DN 0 l
025 DN 25 l
11. Signal output
Aantivalent switching signal
(counter state reached)
12.
Electrical connection
S for round plug connector M 2x , 5-pole
13.
Option
H
gooseneck
Omtropical model
oil-filled version for heavy duty or external use
Options
●Rotor with titanium clamps
Accessoires
●Cable/round plug connector (KB...)
see additional information “Accessories”
●Device configurator ECI-
●Mechanical connection pieces with non-return valve, filter,
constant flow device or customer-specific requirements
available on request
4 pi-ho-fro-omni-c-rri_e V .0 -0
Table of contents
Other Honsberg Measuring Instrument manuals
Popular Measuring Instrument manuals by other brands

Anritsu
Anritsu MS2711B Maintenance manual

Schiltknecht Messtechnik
Schiltknecht Messtechnik ThermoAir3 Operating instruction

Endress+Hauser
Endress+Hauser Proline t-mass 65 operating instructions

IFM Electronic
IFM Electronic Efector 300 operating instructions

Endress+Hauser
Endress+Hauser Levelflex M FMP41C operating instructions

Topcon
Topcon GTS-821A, GTS-822A, GTS-823A, GTS-825A instruction manual