manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Konica Minolta
  6. •
  7. Measuring Instrument
  8. •
  9. Konica Minolta SPAD-502 User manual

Konica Minolta SPAD-502 User manual

SPAD-502
Mac OS 9.2J Adobe Illustrator 10J
CF-1440_Efront.ai2006.11.14
Compact and lightweight for portability
The SPAD-502 is small enough to fit in a pocket and is
extremely lightweight (only 225g) so it can be easily taken
anywhere.
Quick, easy measurements
Measurements are taken by simply inserting a leaf and
closing the measuring head. It is not necessary to cut the
leaf, so the same leaf can be measured throughout the
growing process.
Water-resistant
The SPAD-502 is water-resistant, so it can be used
outside even in the rain.
*It is not immersible, and should not be cleaned with water.
Low power consumption
The SPAD-502 uses LED light sources, resulting in
extremely low power consumption. One set of two AA-size
alkaline-manganese batteries can provide approximately
20,000 measurements.
Small measuring area
The measuring area is only 2 ×3mm, allowing
measurements of even small leaves. A sliding depth stop
is included for accurate positioning of sample leaves.
High accuracy
High measuring accuracy (±1.0 SPAD unit for rice-plant
leaves) allows close examination of growing conditions.
Data memory
The SPAD-502 has memory space for 30 measurements.
Data in memory can be recalled or deleted at a later time,
and the average value of all data in memory can be
automatically calculated.
Reading checker
A reading checker enables users to check that the SPAD-
502 is functioning correctly and providing accurate
readings.
A lightweight handheld meter for
measuring the chlorophyll content of
leaves without causing damage to plants.
The SPAD-502 is a compact meter
designed to help users improve crop quality and
increase crop yield by providing an indication of the
amount of chlorophyll present in plant leaves. The
chlorophyll content of plant leaves is related to the
condition of the plant, and thus can be used to
determine when additional fertilizer is necessary. By
optimizing nutrient conditions, healthier plants can be
grown, resulting in a larger crop yield of higher quality.
Features
CHLOROPHYLL METER
Mac OS 10.3.9J Adobe Illustrator 10J
SPAD-502_Eback.ai 2007.7.5
AHIDPK
Printed in Japan9242-4817-41
2003 KONICA MINOLTA SENSING, INC.
13
The SPAD-502 determines the relative amount of chlorophyll
present by measuring the absorbance of the leaf in two
wavelength regions.
The graph at right shows the spectral absorbance of chlorophyll
extracted from two leaf samples using 80% acetone.
From the diagram, it can be seen that chlorophyll has absorbance
peaks in the blue (400-500nm) and red (600-700nm) regions, with
no transmittance in the near-infrared region.
To take advantage of this characteristic of chlorophyll, the
SPAD-502 measures the absorbances of the leaf in the red and
near-infrared regions. Using these two transmittances, the meter
calculates a numerical SPAD value which is proportional to the
amount of chlorophyll present in the leaf.
Determining when additional fertilizer is necessary
A decrease in the SPAD value indicates a decrease in the
chlorophyll content and nitrogen concentration. This decrease
may be due to a lack of nitrogen available in the soil. This
problem can be solved by adding fertilizer to the soil.
For example, it was determined from past experience that for
Sasanishiki rice plants a SPAD value of 35 or above was
desirable to produce a target yield of 600kg/10a. During the
differentiation and formation of ears, a period of rapid plant
development, the SPAD value fell to between 29 and 32,
indicating that additional fertilizer was necessary.
Type: Handheld meter for measuring chlorophyll using optical density
difference at two wavelengths
Measurement sample: Crop leaves
Measurement system: Optical density difference at two wavelengths
Measurement area: 2 ×3mm
Light source: 2 LEDs (light-emitting diodes)
Receptor: 1 SPD (silicon photodiode)
Display: Measurement data: 3-digit LCD with decimal point
Data number: 2-digit LCD
Data memory: Space for 30 data sets
Controls: Power switch, AVERAGE key, ALL DATA DELETE key,
ONE DATA DELETE key, and DATA RECALL key
Power source: 2 AA-size alkaline-manganese (1.5V) batteries
Battery line: More than 20,000 measurements
Minimum interval between measurements: Less than 2 seconds
Accuracy: Within ±1.0 SPAD unit (at room conditions, SPAD value
between 0 and 50)
Repeatability: Within ±0.3 SPAD units (SPAD value between 0 and 50)
Reproducibility: Within ±0.5 SPAD units (SPAD value between
0 and 50)
Temperature drift: Less than ±0.4 SPAD units/°C
Temperature range: Operation: 0 to 50°C; Storage: - 20 to +55°C
Dimensions: 164 ×78 ×49mm (6-7/16 ×3-1/16 ×1-15/16 in.)
Weight: 225g (7-15/16 oz.) (not including batteries)
Other: Warning buzzer; User calibration function
Specification subject to change without notice
Checking the nutritional condition of plants
The chlorophyll present in the plant leaves is closely related to
the nutritional condition of the plant. As can be seen from the
graph below, the chlorophyll content (represented by the
measured SPAD value) will increase in proportion to the amount
of nitrogen (an important plant nutrient) present in the leaf. For a
particular plant species, a higher SPAD value indicates a
healthier plant.
Theory
Applications
3.5
3.3
3.1
2.9
2.7
2.5
2.3
2.1
1.9
1.7
24 26 28 30 32 34 36 38 40 42
Leaf-blade nitrogen concentration
y =0.079 x - 0.154
r =0.908*** n =68
Measured SPAD value
1984
1985
9.1 9.5 10.3 10.8 12.5 13.0
35
7.1 7.10 7.20 7.30 8.14
30 25 20 15 10 5 0
40
35
30
25
Measured SPAD value
Young ear
formation period
Young ear
growth line
Fully formed
ears appear
Ear differentlation
period
Ear fertility
(1mm)
(3mm)
(8cm)
(16 -18cm)
Sasanishiki rice plant development
Bursting
period
Days before fully
formed ears appear
Date(month.day)
400 500
Ultra-
violet Wavelength Infrared
600 700(nm)
Trancemittance
A
B
SPECIFICATIONS

Other Konica Minolta Measuring Instrument manuals

Konica Minolta CS-150 User manual

Konica Minolta

Konica Minolta CS-150 User manual

Konica Minolta CM-3600D User manual

Konica Minolta

Konica Minolta CM-3600D User manual

Konica Minolta CM-26dG User manual

Konica Minolta

Konica Minolta CM-26dG User manual

Konica Minolta CF-300 User manual

Konica Minolta

Konica Minolta CF-300 User manual

Konica Minolta CM-36dGV User manual

Konica Minolta

Konica Minolta CM-36dGV User manual

Konica Minolta T-10A User manual

Konica Minolta

Konica Minolta T-10A User manual

Konica Minolta CS-2000 User manual

Konica Minolta

Konica Minolta CS-2000 User manual

Konica Minolta CA-100PLUS User manual

Konica Minolta

Konica Minolta CA-100PLUS User manual

Konica Minolta CR-400 User manual

Konica Minolta

Konica Minolta CR-400 User manual

Konica Minolta Vivid 910 User manual

Konica Minolta

Konica Minolta Vivid 910 User manual

Konica Minolta CA-100PLUS User manual

Konica Minolta

Konica Minolta CA-100PLUS User manual

Konica Minolta REGIUS 110 HQ User manual

Konica Minolta

Konica Minolta REGIUS 110 HQ User manual

Konica Minolta MULTI GLOSS 268 User manual

Konica Minolta

Konica Minolta MULTI GLOSS 268 User manual

Konica Minolta CM-2500D User manual

Konica Minolta

Konica Minolta CM-2500D User manual

Konica Minolta CS-7 User manual

Konica Minolta

Konica Minolta CS-7 User manual

Konica Minolta CM-3700D User manual

Konica Minolta

Konica Minolta CM-3700D User manual

Konica Minolta CS-2000 User manual

Konica Minolta

Konica Minolta CS-2000 User manual

Konica Minolta CM-25cG User manual

Konica Minolta

Konica Minolta CM-25cG User manual

Konica Minolta CL-200A User manual

Konica Minolta

Konica Minolta CL-200A User manual

Konica Minolta CM3610D User manual

Konica Minolta

Konica Minolta CM3610D User manual

Konica Minolta CR-14 User manual

Konica Minolta

Konica Minolta CR-14 User manual

Konica Minolta REGIUS 190 User manual

Konica Minolta

Konica Minolta REGIUS 190 User manual

Konica Minolta MYIRO-1 User manual

Konica Minolta

Konica Minolta MYIRO-1 User manual

Konica Minolta CR-10 User manual

Konica Minolta

Konica Minolta CR-10 User manual

Popular Measuring Instrument manuals by other brands

Campbell cs215 instruction manual

Campbell

Campbell cs215 instruction manual

ASD TerraSpec user manual

ASD

ASD TerraSpec user manual

BIRD SiteHawk SK-6000 Operation manual

BIRD

BIRD SiteHawk SK-6000 Operation manual

Alstom CBWatch3 user manual

Alstom

Alstom CBWatch3 user manual

Mindfield eSense Muscle quick guide

Mindfield

Mindfield eSense Muscle quick guide

Gill Instruments WindObserver II user manual

Gill Instruments

Gill Instruments WindObserver II user manual

GESTRA LRG 16-40 Original Installation Instructions

GESTRA

GESTRA LRG 16-40 Original Installation Instructions

sauter FK Series instruction manual

sauter

sauter FK Series instruction manual

Siemens SITRANS F FUS380 operating instructions

Siemens

Siemens SITRANS F FUS380 operating instructions

ATAGO RePo-1 instruction manual

ATAGO

ATAGO RePo-1 instruction manual

Siemens Sitrans F Series quick start

Siemens

Siemens Sitrans F Series quick start

Endress+Hauser Cerabar PMC51B Brief operating instructions

Endress+Hauser

Endress+Hauser Cerabar PMC51B Brief operating instructions

TFA 30.5019 instruction manual

TFA

TFA 30.5019 instruction manual

Megger DCM310 user guide

Megger

Megger DCM310 user guide

Megger FRAX Series user guide

Megger

Megger FRAX Series user guide

Vitrek 951i operating & maintenance manual

Vitrek

Vitrek 951i operating & maintenance manual

Krone KDM30 instruction manual

Krone

Krone KDM30 instruction manual

Panasonic DMR-HW220 operating instructions

Panasonic

Panasonic DMR-HW220 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.